Re: DR5000 - throttle apps compatible with its WiFi
Nags Yes, you can use the DigiTrax LNWI module to connect a throttle supporting WiThrottle protocol to a DR5000.? The LNWI connects to the DR5000 via the LocoNet T socket.? The LNWI converts
By Jay Lennox · #4793 ·
Re: DR5000 - throttle apps compatible with its WiFi
It's a bog standard DR5000. OK, it doesn't support the WiThrottle protocol 'as is'. I have a DigiTrax LNWI module - I'll believe that should connect via the DR5000's LocoNet.
By Nags · #4792 ·
4018 won't enter programming mode
Hi Guys, I have several DR4018's run from a YD7001. I cannot get one of the 4018's to stay in programming mode. I can push the button and the red light comes on, but when I release the button the
By Pete S. · #4791 ·
Re: DR5000 - throttle apps compatible with its WiFi
What does that mean.
By terry lee · #4790 ·
Re: DR5000 - throttle apps compatible with its WiFi
For a DR5000, that is correct. For a to YD7001 upgrade (YD9401) it¡¯s incorrect. The YD7001 talks native WiThrottle.
By karst.drenth · #4789 ·
Re: DR5000 - throttle apps compatible with its WiFi
I have the upgraded DR5000 with the YD9401 Upgrade Module, and it works fine on my Android phone with Engine Driver. On my 009 layout and it also controls MTB motorised point motors via Yamorc YD 8116
By terry lee · #4788 ·
DR5000 - throttle apps compatible with its WiFi
I know the Z21 app works (and I've used it) but I'm not clear about other apps. From digging around it seems apps such as WiThrottle or Engine Driver need to go through JMRI or something like a LNWI
By Nags · #4787 ·
Re: Short Circuits on Layout with several YD7403 Boosters
I suggest that the setting you want to change is the GPON/GPOFF to stop it forwarding short circuit events over LocoNet. I am not sure whether no highlight means it isn¡¯t sent or it is sent, best to
By Iain Morrison · #4786 ·
Re: Short Circuits on Layout with several YD7403 Boosters
Thanks for responding Iain, Did you mean the Button Action menu? It defaults to "Power On/Off Global", so could you mean "Power On/Off Local"? (I can't test that for a few days unfortunately) The only
By Oldngrey · #4785 ·
Re: Short Circuits on Layout with several YD7403 Boosters
You need to change the options within the booster and tell it not to forward the short to the command station. You can change the actions in the track power options. I would also feed the turnouts
By Iain Morrison · #4784 ·
Short Circuits on Layout with several YD7403 Boosters
My apologies if this has already been answered. I have several YD7403 boosters connected via Loconet B to my YD7001 Command Station. They work fine but I would prefer a short circuit somewhere on a
By Oldngrey · #4783 ·
Re: Z21 and s88 yd6o16es modules
any idea what the solution is. I've tried different power supplies. End of bus resistors from DCC concepts. Why do they work perfectly with the ecos, but within 20 minutes coupled to the DR5000 they
By Alan Watt · #4782 ·
Re: Z21 and s88 yd6o16es modules
It happens with other systems also Many Thanks Iain Morrison https://wimorrison.com/ [email protected]> wrote:
By Iain Morrison · #4781 ·
Re: Z21 and s88 yd6o16es modules
just wondering is the yd7010 much different to the DR500/YD9401 a i was thinking would using the yd7010 would solve my problem with the cobalts losing their addresses as this problem only occurs when
By Alan Watt · #4780 ·
Re: YD6016ES-CS N gauge current detction
As long as you motors or wagons are drawing more than 2mA the you will have zero issues, especially given that the YD6016xx is sensitive to less than 2mA. If the wagons do not have anything drawing
By Iain Morrison · #4779 ·
YD6016ES-CS N gauge current detction
Good afternon I was wondering if anyone had an experience using the YD6016ES-CS detecting N gauge rolling stock and the reliability? Many Thanks
By Andrew Jebb · #4778 ·
Re: YD8008 with YD6940 and Kato Unitrack turnouts
I have a Kato double crossover T-Trak module with I use a 9 volt battery to run it with a dpdt monetary switch. what you might want to try is powder graphite into the switch it self to help over come
By James Braxton · #4777 ·
Re: DR4102 Relay Alternatives
There are variations with these modules including operating voltage and trigger - many are just Lo others are either Hi or Lo by jumper. Note you need to set the trigger source jumper to use either
By Nags · #4776 ·
Re: DR4102 Relay Alternatives
Could you go into a little more detail on how you wire up those modules. I bought a 8 relay module thinking this would work, but I can't seem to figure out how to wire it given the switched output of
By Rich · #4775 ·
Re: DR5000 with installed YD9401 upgrade. WWW server doesn't work, stuck until power off / power on #DR5000 #YD9401
Not use it, see the answer to your ticket !!
By karst.drenth · #4774 ·