开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育
Using YD7001 with a DR4088CS or YD6016ES
I have a small iTrain test bench layout controlled by a YD7001. To control my Blocks I have been using either a DR4088CS or YD6016ES connected directly to the EXTN88 IN port of the YD7001. Whilst this
By Roy Endersby · #4746 ·
Re: YD8116 programming
Pete The number is, as you guessed, used with DCCExt. This allows you to use a single address to make complex signalling done because the decoder does the work rather than you creating a (sometimes)
By Iain Morrison · #4745 ·
Re: YD8116 programming
Hi Iain and Oldngrey, Many thanks for your earlier replies. Well I dived in and bought 7 x YD8116, and the USB to ES link (FTDI) adaptor, and I've had one on the bench and been playing. Thanks
By Pete S. · #4744 ·
Digitrax DS51K1 switch decoder not working with YD7010
Hi, We are migrating from the DR5000 to the YD7010. ?We have previously controlled switch decoders with the Z21 app on iPad. The DS51K1 decoder does not respond when connected to the YD7010. ?We
By @Kysouthern · #4743 ·
Re: How to control S88N devices with a TCS CS-105
I have a PR4, so I am considering using this as a test of whether the S88N conversation is done in the DR4088LN-CS. thanks -- Heath @ Human[c]ity http://www.humancity.org ( http://www.humancity.org/
By Heath @ Human[c]ity Junction · #4742 ·
YD7403 Question
Hi, I have several YD7403 Boosters on the lower deck of my layout. I will have 2 parallel tracks going up to the upper deck via a helix. The tracks come from different parts of the layout and there
By Oldngrey · #4741 ·
Re: How to control S88N devices with a TCS CS-105
In theory, I think this could work. I doubt that specific combination of devices has been tested before. It may "just work", provided all the devices are configured appropriately. I see you have
By Stuart Baker · #4740 ·
Re: How to control S88N devices with a TCS CS-105
Stuart, You name just came up on my discord ( https://discord.gg/tNqrmzX6 ) . We were discussing in throttle consisting versus when the cosist get's sent to the command station so I could grab it
By Heath @ Human[c]ity Junction · #4739 ·
Re: How to control S88N devices with a TCS CS-105
Heath, I would suggest posting this question on the LCC users group. You might get some better suggestions over there. There might be someone who already has, or is willing to help with building, an
By Stuart Baker · #4738 ·
How to control S88N devices with a TCS CS-105
I am at the point in my model railroading journey that I want to get away from Digitrax consisting and move to an NCE style system. This means that the upgrade choice would be the TCS CS-105. On my
By Heath @ Human[c]ity Junction · #4737 ·
Re: Unable to connect to YD7001
Perhaps go into the admin of the router and assign the YD7001 a static IP address - the same one that originally worked with the YD7001…. i have windows 11 desktop and i use static IPs because i
By Adam Eddy · #4736 ·
Re: Unable to connect to YD7001
Thanks Ian, Was just about to follow your suggestion, I was just using regedit when I read your post.? ?I found some keys removed them thought I would reinstalled and follow your suggestion.? But
By Doug Johnson · #4735 ·
Re: Unable to connect to YD7001
Install something like Revo Uninstaller <https://www.revouninstaller.com/> to remove the programs and clear out the registry keys (which it will be display for you) after it has been uninstalled and
By Iain Morrison · #4734 ·
Re: Unable to connect to YD7001
Ok small update. Got my laptop out which I use to control my backup and second YD7001 and it conects perfectly fisrt time with my first YD7001 by USB and ethernet. So my problem is the Windows 11
By Doug Johnson · #4733 ·
Unable to connect to YD7001
Hi all, This is driving me mad I cannot get round it. I have had this system running fine for over a year (upgraded DR5000) and it has been fine. A few days ago I had to restart my router and the
By Doug Johnson · #4732 ·
Re: YD7001 stuck in demo mode etc.
Update on my problem with YD001 upgrade. I returned it to the dealer that I purchased the upgade from and he discoverd that the wifi update had not been saved for some reason. The YD7001 has now
By terry lee · #4731 ·
Re: YD7432 Reverser - recommended length of the Sensor track
@karst.drenth: Your timely reply is very much appreciated. I will follow your advice and will be ordering YD7432 Reversers as well as an ESU L.Net converter. Also, I am looking into connecting
By TrainZeal · #4730 ·
Re: YD7432 Reverser - recommended length of the Sensor track
They don't have to be *detected* , but have at least the *same voltage drop* (1.1V) as the sensor tracks are measuring for. You also can (or better should if you have more Current-Sense detection )
By karst.drenth · #4729 ·
Re: YD7432 Reverser - recommended length of the Sensor track
You ask whether the YD7432 will work when “connected via S88 for occupancy monitoring” – the YD7432 uses LocoNet to provide the occupancy reporting, not S88 ? Sent: 08 January 2025
By Iain Morrison · #4728 ·
Re: YD7432 Reverser - recommended length of the Sensor track
@karst.drenth Could you please elaborate why it matters to have "sections adjacent to S1 and S2 to also be supplied with a current sensor" ? In a reversing loop, sections S1 and S2 are usually next
By TrainZeal · #4727 ·