Nags
?
Yes, you can use the DigiTrax LNWI module to connect a throttle supporting WiThrottle protocol to a DR5000.? The LNWI connects to the DR5000 via the LocoNet T socket.? The LNWI converts WiThrottle protocol to LocoNet for transmission to the DR5000.
?
At the York Railway Modellers club here in Toronto, we have connected several different throttle types to the DR5000 using this method - TCS100s, TCS50s, iPhones running the WiThrottle app, and Android phones running the Engine Driver app.?
?
One limitation you should be aware of when using an LNWI - each one supports up to 4 connections, and if one throttle disconnects, the only way to get that connection available again is to power off and on the LNWI.? Otherwise they are very stable.
?
I am not trying to sell you on upgrading your DR5000 to a YD7001 using the YD9401 module, but this does allow you to get direct WiThrottle protocol support, plus other protocols simultaneously.? The other advantage is that if a throttle using WiThrottle protocol disconnects from the YD7001, the connection is immediately available for another throttle to use.
?
Full disclosure.? At York Railway Modellers, I converted our two DR5000s to YD7001s about 20 months ago.? They are very stable - we are still using our six LNWIs with them, and we are using the built in WiThrottle support to add additional connected throttle capacity. I worked with Karst over several months to request and test software enhancements.? He is very supportive of the customers using his products.
?
Jay Lennox
York Railway Modellers - Toronto