Locked Re: problem with dispatcher

 

Hi Luc
Make sure you have good occupancy detection.
You can try:
Use large values for debounce off in sensors.
Use stop by speed profile.
Use Internal stopping sensors. Internal sensors that are set X seconds after entry to block (actions in transits)
Hope that helps.
Steve G.


Locked Re: Zimo MX10 support

 

Well a few years later, and about to revisit this.

I have an M10, and run outdoors, so the connection needs to be Ethernet.
I have been able to use the Roco android app to control trains, so the ZCAN20 must be working over Ethernet
So all I need is JMRI to be able to direct that protocol over Ethernet.

So how do I do this?

Greg


Locked Re: PanelPro CTC tools #ctc-tool

 

Extracted fine for me in Windows 8 using PKzip. Maybe bad download of the zip file?

Barry Draper

________________________________________
From: [email protected] <[email protected]> on behalf of coolerman10002003 via Groups.Io <coolerman10002003@...>
Sent: Monday, December 2, 2019 2:20 AM
To: [email protected]
Subject: Re: [jmriusers] PanelPro CTC tools

Dave,

You new file un-zips up as a "__MACOSX" file with no open-able files inside

Ray Eiser


Locked Re: Max Speed with a QSI, Version 6 (Seeking enlightenment) #speedprofiling

 

Oh I trust you.? I was just making a suggestion to see if the speed table issue could be figured out or resolved. Then he can do what he pleases.

Marc


Locked Re: MTH DCS/DCC Decoder #mth

 

Dave, It depends.

Reading thru the three existing? DecoderPro definition file for MTH .

Early version decoder was Reset : CV55 = 55 on program track only

The next decoder revision has this :

In OPS MODE ONLY? (Program on Main mode)

Reset All CV's : CV8 = 8
Reset ALL CV's except Speed Table : CV8 = 192
Reset Volumes, Smoke, and Lioght settings: CV8 =64
Reset Address : CV8 = 128

On Program Track only (Service Mode)

RESET? all CV's : CV55 = 55

Marc


Locked Re: Max Speed with a QSI, Version 6 (Seeking enlightenment) #speedprofiling

Nick
 

Marc,

I've worked with them since they have been around. Trust me, the instability makes setting them up, just not worth the effort if they do not get upgraded. One short circuit and they revert to defaults and only last as long as the next short.

Nick Kulp

"I'm not a failure. I started at the bottom and I found it easily attainable. Life is too short to set unattainable goals"

- Nick Kulp



On Monday, December 2, 2019, 01:03:12 PM EST, <forfoum@...> wrote:


Strangly ALL the QSI Ver 6 definitions in DecoderPro contain? Speed Table option. Even the older pre-V6 definitions contain Speed Table.

As per QSI manual : http://qsindustries.com/manuals/full%20dcc%20manual.pdf

If CV5 = 0, 1 or 255 the value used for any calculation is 255.? This also affect all? Speed Table and User Defined Speed Table.
So if you want to lower top speed, set CV5 =2 thru 255

" CV 5 sets a maximum voltage for the motor to any value between 2 and 255. A value of 0, 1, or 255 provides maximum motor voltage at maximum throttle. "

So setting CV5 =217 would apply 85% of full available power.? A value of 128 in CV5 would be 50% power.

Marc


Locked Re: MTH DCS/DCC DECODER #mth

Video7105
 

开云体育

Hey Bob,?
Look for the Proto 3 sound labeling on the box or write up

Dave
In PA

Sent from iPhone Xs Max

On Dec 2, 2019, at 08:59, Bob McClain via Groups.Io <mcclainbob55@...> wrote:

?Understand that newer MTH engines have a DCS/DCC decoder that will work fine with Decoder Pro.? I am thinking of purchasing a Dash 9 model.? How can I find out if that engine has the? DCS/DCC decoder?
Thanks
Bob


Locked Re: MTH DCS/DCC Decoder #mth

Video7105
 

开云体育

I guess it’s Foot in the mouth, since it’s a non signer of this post.?

Of course your CV8 comment doesn’t work. ?To reset a MTH decoder, you choose address 55 and then CV55 and a value of 55. ?This must be done on the main, not program track. If you want to reset a MTH decoder

I have never had a problem reading the programmable ?CV’s using Decoder Pro, using program mode.?

More fake news am myths, that plagued MTH, in forums.?

Now if you are a guy or woman, not sure with no signature, that needs the DCC sounds of toilets flushing etc. Then MTH in DCC mode isn’t for you

Dave
In PA

Sent from iPhone Xs Max

On Dec 2, 2019, at 14:09, fcot2002@... wrote:

?
Good evening,
?
I have some problems with MTH / DCC decoder.
?
JMRI Decoder Pro is never stable when detecting and reading CVs.
?
In DCC impossible to put the CV 8 to 8 to reset the decoder.
?
Now I have no traction or sound in DCC, but traction OK in analog.

Thank you in advance !


Locked Re: False "Online" with DecoderPro

 

Not a problem with Digitrax, it is a problem with JMRI who does not poll and confirm the Digitrax Command Station is present or not ,for what reason I do not know.?

I have a Locobuffer-USB, Digitrax PR3, PR4, Locobuffer-Serial and none of them cause me grief for as long as I have had them.
They all connect to either of my two DCS100's or Zephyr on demand with the proper setup. And I have jumped and leapped between Windows versions and JMRI versions back and forth.

I was simply pointing out that a wrong setup in JMRI? can lead you down a wrong trail.

Heck if you define? System Manufacturer as "NONE" and System Connection as "No connection" in Preferences, both Service and OPS mode programming show up GREEN (JMRI 4.17.6).

Marc?


Locked Re: False "Online" with DecoderPro

 

开云体育

I agree this is a problem with Digitrax.? I tried for 5 weeks to get past the 306 error with my PR3 and could never do it despite the green indicators on the bottom of the page (and all the sage advice from those of you on this forum).? I also could never get the Digitrax software drivers to associate with the C0M port so eventually I gave up and bought an NCE Power Cab and USB interface.? The driver downloaded, associated with COM 4 immediately, and the system has worked like a charm ever since.

?

Jim

?

From: [email protected] <[email protected]> On Behalf Of forfoum via Groups.Io
Sent: Monday, December 2, 2019 3:39 PM
To: [email protected]
Subject: Re: [jmriusers] False "Online" with DecoderPro

?

If that system is running a JRMI version prior to 4.17.x, update date it,? There were several issues with PREFERENCES and DEFAULTS.

What is nice about JMRi and NCE is that the NCE system is polled for a response and will eventualy time out if no response then both Service mode and OPS mode will go from GREEN to RED as unavailable

This is not the case with several other systems.? Other systems, as long as the Com port is valid (and present), they are happy even thou nothing might be at end of cable.? The indications will be GREEN.? Perfect example is JMRI and Digitrax. the Command Station is not polled.? Set Preferences to a valid port that, unfortunately, does not have the Command Station at the end of it, you get all GREEN to go indications and 306 errors,

Marc


Locked Re: False "Online" with DecoderPro

 

If that system is running a JRMI version prior to 4.17.x, update date it,? There were several issues with PREFERENCES and DEFAULTS.

What is nice about JMRi and NCE is that the NCE system is polled for a response and will eventualy time out if no response then both Service mode and OPS mode will go from GREEN to RED as unavailable

This is not the case with several other systems.? Other systems, as long as the Com port is valid (and present), they are happy even thou nothing might be at end of cable.? The indications will be GREEN.? Perfect example is JMRI and Digitrax. the Command Station is not polled.? Set Preferences to a valid port that, unfortunately, does not have the Command Station at the end of it, you get all GREEN to go indications and 306 errors,

Marc


Locked Re: Max Speed with a QSI, Version 6 (Seeking enlightenment) #speedprofiling

 

Strangly ALL the QSI Ver 6 definitions in DecoderPro contain? Speed Table option. Even the older pre-V6 definitions contain Speed Table.

As per QSI manual : http://qsindustries.com/manuals/full%20dcc%20manual.pdf

If CV5 = 0, 1 or 255 the value used for any calculation is 255.? This also affect all? Speed Table and User Defined Speed Table.
So if you want to lower top speed, set CV5 =2 thru 255

" CV 5 sets a maximum voltage for the motor to any value between 2 and 255. A value of 0, 1, or 255 provides maximum motor voltage at maximum throttle. "

So setting CV5 =217 would apply 85% of full available power.? A value of 128 in CV5 would be 50% power.

Marc


Locked Re: Max Speed with a QSI, Version 6 (Seeking enlightenment) #speedprofiling

 

In many cases, the new Decoder Buddy is a drop in for QSI OEM decoders.
Takes about 10 minutes to get the board in place.
You then have a 21-pin motherboard. (I prefer Loksound, but works with any 21-pin decoder)
Thomas
DeSoto, TX


Locked Re: MTH DCS/DCC Decoder #mth

 

Good evening,
?
I have some problems with MTH / DCC decoder.
?
JMRI Decoder Pro is never stable when detecting and reading CVs.
?
In DCC impossible to put the CV 8 to 8 to reset the decoder.
?
Now I have no traction or sound in DCC, but traction OK in analog.

Thank you in advance !


Locked Re: Max Speed with a QSI, Version 6 (Seeking enlightenment) #speedprofiling

 

Nick and Dave,
Thank you for all the information. It has helped tremendously! I tend to prefer the SoundTraxx products so I'll take out the old decoder and update it with one of their's.
Sincerely,
Michael Boyle


Locked Re: PanelPro CTC tools #ctc-tool

 

Ray,

Ignore the __MACOSX directory.

The one you was is the CTC_Tutorial.jmri directory. ?This is a complete JMRI profile.

I assume your are running Windows. ?C:\Users\<username>\JMRI normally contains all of the user content. ?Your default JMRI profile, My JMRI Railroad, will normally be located here. ?Move CTC_Tutorial.jmri to C:\Users\<username>\JMRI.

If you have the profile selector enabled, the new profile will show up in the profile list. ?If you have not enabled the profile selector, start PanelPro with your default profile, go to Preferences >> Config Profiles. ?Select CTC Tutorial and click on Activate. ?When you save and re-start, the tutorial profile will be opened.

Note: ?If you want to use the profile selector in the future, select the Show profile selector button at the bottom of the Config Profiles screen.


Dave Sand



----- Original message -----
From: "coolerman10002003 via Groups.Io" <coolerman10002003@...>
Subject: Re: [jmriusers] PanelPro CTC tools
Date: Monday, December 02, 2019 4:20 AM

Dave,

You new file un-zips up as a "__MACOSX" file with no open-able files inside

Ray Eiser



Locked Re: MTH DCS/DCC Decoder #mth

Video7105
 

Sounds like the loss of power issue is a track issue, not a manufacture problem.....

Happy with all my Proto 3 Sound Units , especially after doing their software updates

Dave
In PA

Sent from iPhone Xs Max

On Dec 2, 2019, at 11:58, Al <babinskya@...> wrote:

?Bob, our club has two MTH locomotives one is an A-B-A F unit and the other a Milwaukee Road Bi-Polar. They respond to programming with Decoder-Pro but have one feature that can't be changed. In order for the sound and lights to be active you must push F3 prior to applying power to the motor. I contacted them and they told me that they would not change that feature. At any rate they run nice but if they stop due to loss of power and then start up again they run silent until you stop and click on F3 and start it again. Hope this helps,
Al Babinsky


Sent from Xfinity Connect Application



Locked MTH DCS/DCC Decoder #mth

 

Bob, our club has two MTH locomotives one is an A-B-A F unit and the other a Milwaukee Road Bi-Polar. They respond to programming with Decoder-Pro but have one feature that can't be changed. In order for the sound and lights to be active you must push F3 prior to applying power to the motor. I contacted them and they told me that they would not change that feature. At any rate they run nice but if they stop due to loss of power and then start up again they run silent until you stop and click on F3 and start it again. Hope this helps,
Al Babinsky


Sent from Xfinity Connect Application


Locked Re: Inverted option grayed out in turnout table

 

I understand there are work arounds to get the turnout behavior that we seek.? Plan A was use the inverted option.? That will not work because the option is grayed out.? I am sure there is a Plan B and a Plan C. My original question was "Why is the inverted option grayed out?"? Is it an idiosyncrasy of LCC?

Dan K.......
ARHS


Locked MTH DCS/DCC DECODER #mth

 

Understand that newer MTH engines have a DCS/DCC decoder that will work fine with Decoder Pro.? I am thinking of purchasing a Dash 9 model.? How can I find out if that engine has the? DCS/DCC decoder?
Thanks