Locked Re: Add Numerical Display to Spped Table
Hi Bob, I just did a CVS update and run to have a look at the value boxes on top of the sliders and yes the font is pretty small. Even when you set the value to 255 the text only fills about 2/3 of
By Alex Shepherd <ashepherd@...> · #231 ·
Locked Re: Add Numerical Display to Spped Table
How about this Bob, How About a magnifying feature to work with the small point size. When one clicks on a slider adjustment or places the pointer on the small numerical box above it, the numerical
By Mark Gurries <gurriesm@...> · #230 ·
Locked Re: Add Nemerical Display to Speed Table
I've added a couple of buttons to: *) Set the curve back to the default 0 -> 255 straight line *) Set it to a straight line between existing endpoints *) Set it to a log curve between existing
By Bob Jacobsen · #229 ·
Locked Re: Add Numerical Display to Spped Table
Sorry to be so long getting back to this topic. I've made a couple of attempts at getting the digits to line up vertically, and there doesn't seem to be a clear-cut way to do it. Perhaps somebody
By Bob Jacobsen · #228 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
the It is specifically the LH200 handheld which doubles as a command station. Although it can program decoders on the main and on a programming track, it cannot communicate with decoders over
By sotars · #227 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
Ouch is right!!! I don't understand the Lenz product line. What should we put in the web pages, etc, so that other people don't hit the same problem? E.g. is it just the Set 02 that won't work with
By Bob Jacobsen · #226 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
Bob Thanks for the help but I have just heard from Debbie Aimes from Lenz and the LH200 can not be used to program decoders over the expressnet. I have oredered an LZ100 command station
By sotars · #225 ·
Locked Re: DecoderPro help
The programs are written to take control of the serial port, so only one can run at a time. For those using a Digitrax system, Alex Shepherd has built a "client-server" capability. You can run one
By Bob Jacobsen · #224 ·
Locked Re: DecoderPro help
we're not too consistent on that) contains all of the code that exists. It's got a complicated menu bar with lots of things to try, and it's missing even the most basic of instructions, so it's
By Jon Miller <atsf@...> · #223 ·
Locked Re: DecoderPro help
If I understand your question properly, there are two parts to the answer. Right now, "running trains" has only rudimentary support in the code. People seem to have been more interested in aspects of
By Bob Jacobsen · #222 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
Yes, it's pretty clear that everything is communicating. Can Windigital 8.5 program decoders? If so, that means that the command station will accept programing commands, and there's something wrong
By Bob Jacobsen · #221 ·
Locked DecoderPro help
bob,I was interested to see that I was not the only one having problems downloading the other programs used with the decoder pro.we(my friend and I) have installed decoder pro and find i very easy to
By peter smith <trainman2543@...> · #220 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
Bob I have just tried to control a loco with Windigital 8.5 and it works so the Com port is set up OK. Alex
By sotars · #219 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
xbus etc and it is as far as I can see acommand station running Ver 3.0 of the software. If it does not work it looks like I will ahve to spend another ?150 on an LZ100!!!!!!! Not a happy
By sotars · #218 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
That's interesting. Those are messages from the LI100, so the program is successfully exchanging messages with the LI100 over the serial link. 1 4 5 is from the LI100 itself, and means that
By Bob Jacobsen · #217 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
Thanks for the reply. I have tried to send the command but there is nothing in the monitor. However when i try to ident the loco settings or decoder settings from the programmer the following
By sotars · #216 ·
Locked Re: Lenz LI100F XP Pro & DecoderPro
Is there a difference between the LI100 and LI100F? A systematic approach to diagnosis will probably help here. First, get a consistent set of settings. The best starting place for settings is 9600
By Bob Jacobsen · #215 ·
Locked Re: Lenz LI100F, XP Pro & DecoderPro
I test DecoderPro on other protocols (NCE, Digitrax) under XP Home and it works fine. Would XP Pro be different? I can try the Lenz protocol with XP Home this evening, will let you know. Bob --
By Bob Jacobsen · #214 ·
Locked Lenz LI100F, XP Pro & DecoderPro
Can anyone tell me please if DecoderPro works under XP Pro? It seems to load and run well but I have been unable to get it to talk to the interface. I get Program error: talking to command station.
By sotars · #213 ·
Locked Lenz LI100F XP Pro & DecoderPro
Can anyone please tell me if DecoderPro works with XP Pro? I took delivery of the LI100F on saturday and have it connected to a Set02. The software loads and appears to work correctly however I