¿ªÔÆÌåÓý

Date
Locked Re: Turnout automation
Getting back to the original question you asked, no, there¡¯s not a simple setup to hold an Internal Turnout in one position. You can create a Logix that looks for the Turnout to change, and
By Bob Jacobsen · #150339 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
"Verbal feedback" is for QSI decoders only and is on the QSI Misc tab and is called "Programming Verbal Acknowledgement".? It's bit 0 of CV 62.? But it only applies to Ops Mode programming (POM),
By Michael Mosher · #150338 ·
Locked Re: Turnout automation
In the turnout edit you should have a Feedback tab. In there you can select the one or two sensor option. After that, you'd be able to enter the sensors for the feedback. -Ken Cameron, Member JMRI
By Ken Cameron · #150337 ·
Locked Zimo Function Decoders
I bought a zimo MX478W decoder to activate a servomotor. I find no reference in the list JMRI... Sincerely ~JES~
By Labo44 · #150336 ·
Locked Re: Turnout automation
I have all the turnouts added as Internal (with addressing IT.IOT$40:0:10.0.0.100) and this is probably the problem. When adding internal turnout there are no options 1/2 wire nor maintained/pulse
By Quinametin · #150335 ·
Locked Re: Turnout automation
There are options when you set up a turnout to make it one wire or two wire. I assume you are using the default which I believe is 2 wire. You can also the output type to maintained or pulse. Try
By James LeFevre · #150334 ·
Locked Turnout automation
Is there an option to setup turnout permanently in one position? I mean when I set it up in JMRI to CLOSED and someone will change it's position by hand on the layout to THROWN JMRI will put it back
By Quinametin · #150333 ·
Locked Re: L1USB Ethernet Adapter Error ? Help
Dave, ? I don't save logix if I know there are errors, but I this is one which does:- ?IX:AUTO:0001C1? C1?? ?? Antecedent: (R1 and R2) or (R3 and R4)? ??? [x]? R1? IF? Turnout "pt01"
By Alan Gibbs · #150332 ·
Locked Re: Loconet Monitor Startup
That makes sense to me. The failures are because the command station (Zephyr+) is connected to my programming track. There would logically be all failures. Thanks all. John Griffin -- John
By John Griffin · #150331 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Ken, I found 1, 2, and 3. They were all good. Where do I find the "verbal feedback" option at? Also are you saying to remove the grain of wheat bulb? I also have gone back to 4.12 version. I have also
By cwt2168@... · #150330 ·
Locked Upgrade from 4.11.2 to 4.12 failed
I have upgraded many times without problems, but my latest upgrade has failed. I am running on a Toshiba C655, Win 10, Java 8 181, with a Locobuffer USB connected to a Digitrax DCS 200. No error
By diesele645@... · #150329 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on Loksound and Broadway Limited decoders. I can read the digitrax decoders.
Hi Try a resistor between 500 and 2k ohms for Lenz, tcs. The value of the resistor matters. The BLI decoders need the audio feed back disabled. Steve G.
By Steve_G · #150328 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on Loksound and Broadway Limited decoders. I can read the digitrax decoders.
I just bought 5 emd locos from broadway limited. They are the new sound decoders something3 Jmri will not identify the decoder on a random basis. Try selecting the decoder from the list and write a
By AD · #150327 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on Loksound and Broadway Limited decoders. I can read the digitrax decoders.
I was never able to consistently read TCS, Lenz and NCE N-scale decoders with an original Zephyr, either direct from the command station, or with DecoderPro running on a Linux laptop connected with a
By Russ Brodfuhrer · #150326 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Cwt, First I'd suggest you stick with 4.12, there are issues in 4.10 that are likely to bite you sometime. Next, make sure you can select if you use the PowerPax and select to disconnect the grain of
By Ken Cameron · #150325 ·
Locked I am unable to read what type of decoder from the program track and mainline on Loksound and Broadway Limited decoders. I can read the digitrax decoders.
I am using version 4.10 and have tried 4.12 JMRI on windows 10. I also am using a RR-CirKits LocoBuffer-USB version 3 on com port 3, a Digitrax DCS 200 and a program booster (PowerPax) to the program
By cwt2168@... · #150324 ·
Locked Re: Turnout minor issue
Thanks Steve Yes I did that and all are well now, regards Manos SV1IW
By Manos Darkadakis <sv1iw@...> · #150323 ·
Locked Re: Turnout minor issue
Hi Manos You saved them: tools->file->save->save configurations only to file. Then to load: Panels->Open Panels Steve G.
By Steve_G · #150322 ·
Locked Re: Turnout minor issue
Thanks again Ken, got them all sorted out, so far. If I load the tables from panel menu (had them saved with a different name) all return as expected. The reason I didn't do this before is that
By Manos Darkadakis <sv1iw@...> · #150321 ·
Locked Re: Loconet Monitor Startup
John, What you are seeing is one of two things. First it could be the command station. When it does a power on to the track, it sends special commands (what you see) to ask all devices on the layout
By Ken Cameron · #150320 ·