Since it is a fast acting event... the?first thing I would do is replace the receive first RF amp.?
Q1 dual gate mosfet.? 3N211 transistors are still easy to find.? But any decent, four leg dual gate mosfet of that ilk.. will tell you if it’s bad.? I doubt the receive line fuse is blown, as others might suggest.? |
Re: FT-101E Receive Fault
开云体育Hi Noel, The fault is only on receive, I have not tried to transmit yet.? I have found the info about neutralization, but not sure how this affects receive only. Steve G4AQB ? Sent from for Windows ? |
Re: FT-101E Receive Fault
Steve the RF gain circuit is connected to PC 1181 - MJ(1), PB 1183 -MJ(3), PB 1582- MJ(7). Check the voltage chart. pg 4-17 Emerson PP6EW Em qua., 8 de set. de 2021 às 01:14, Steve <steve@...> escreveu: Hi |
Re: FT-101e Meter issue
Timothy Brown WB2PAY
开云体育?
Roger,
?
Yes, I agree I have to check the circuit before
replacing the meter and destroying a new meter.
I will search ebay again and see if I can find the item
you mention.
Thanks
? Tim Brown, WB2PAY,
? ? From: [email protected] [mailto:[email protected]] On Behalf Of Roger VE7LB Sent: Monday, July 19, 2021 12:00 PM To: [email protected] Subject: Re: [Yaesu-FT-101] FT-101e Meter issue When I search eBay for FT-101 meter I get about 10 results for S meters including one for $16 delivered. Item # 114863571802 . Before putting in a good meter suggest checking the IC current measurement section resistors first. 73 Roger VE7LB |
Re: FT-101e Meter issue
Timothy Brown WB2PAY
开云体育While?evaluating?an old rig for a friend, I
discovered the meter in a FT-101E is not
working.
I found using a millivolt source and series current
limiting resistor that the meter coil is open.
Substituting my Fluke on the 300mv range I was able to
get readings, although it is difficult to
correlate them to what they would be on an analog
meter.
?
I could not find? specs on what the micro amp
rating?for the meter.
?
Searching epay, I found rigs to be parted out but no
individual meter movement that has been scavenged
from a rig.
?
I would be interested in finding data about and ?a
source for the meter movement.
?
Thanks
?
Tim Brown, WB2PAY,
Licensed since 1962 |
Re: modulation usb lsb calibration ft-101zd
ok grazie iz8jfa 73
------ Messaggio originale ------
Da: "Roger VE7LB" <Roger_VE7LB@...>
Inviato: 13/07/2021 20:36:56
Oggetto: Re: [Yaesu-FT-101] modulation usb lsb calibration ft-101zd Hi Franco, |
Re: modulation usb lsb calibration
Hi Franco,
Many FT-101's have had their Carrier Crystals adjusted to match the aging crystal filter. A different white noise sound when switching from USB to LSB or vice-versa is the usual indication of a problem. Please see the pdf located in our Files Folder #6 FT-101ZD Carrier Crystals Adjustment. Also good for the original FT-101 series. Also please see the FT-101ZD operators manual located in folder #6 page 35. 73 Roger VE7LB |
Re: modulation usb lsb calibration ft-101zd
Hi Franco,
Many FT-101's have had their Carrier Crystals adjusted to match the aging crystal filter. A different white noise sound when switching from USB to LSB or vice-versa is the usual indication of a problem. Please see the pdf located in our Files Folder #6 FT-101ZD Carrier Crystals Adjustment. Also good for the original FT-101 series. 73 Roger VE7LB |
Re: modulation usb lsb calibration
I don't know but from the service manual I can't figure out what I need to adjust ------ Messaggio originale ------
Da: "Emerson PP6EW via groups.io" <elsh_x@...>
Inviato: 13/07/2021 16:10:37
Oggetto: Re: [Yaesu-FT-101] modulation usb lsb calibration
|
Re: frequency calibration ft-101zd
tc01 now adjusted the frequency is all correct on the whole hf range
thank you
izjfa 73 ------ Messaggio originale ------
Da: "Roger VE7LB" <Roger_VE7LB@...>
Inviato: 08/07/2021 17:54:14
Oggetto: Re: [Yaesu-FT-101] frequency calibration ft-101zd Hi Franco, |
frequency calibration ft-101zd
hello my ft-101zd is not perfectly in frequency it is out of frequency example if I go to 141000 mhz the correct frequency is 140998 mhz to center it in frequency I have the instruments of the laboratory frequency meter but I don't know what I need to adjust can someone help me?
iz8jfa franco 73 |