Re: HP 5328A
Sorry to hijack this thread in the first place, could you tell me please the part number of the sequencer ROM (the 256 x 16 bit 1818-xxxx which is on the mainboard near the display)? I've repaired
By
Francesco Messineo
·
#133370
·
|
Re: HP 5328A
Lionel, I have one on duty at the bench with 1.3GHz Channel C (I found it to be good to about 1.65GHz), the enhanced DMM, ovenized reference, two channels with the better front end, and I also have
By
Radu Bogdan Dicher
·
#133369
·
|
HP 5328A
I had two working frequency counters HP5328A: - one with the 500 MHz C channel and a digital voltmeter (the one with auto DCV range, a filter switch, and two push buttons to read A and B levels), a
By
Lionel_C
·
#133368
·
|
Re: Fixed my HP 5345A today!!
Impressive work! Lifting a Super-Pro, I mean. I¡¯m 76, not sure I could do that any more, if I had one, which I don¡¯t any more. Jeremy Nichols Sent from my iPad 6.
By
Jeremy Nichols
·
#133367
·
|
Re: E4407B Step Attenuator
The 30 dB pad part number is 1GT1-2866 and is used on a wide variety of attenuators. However, unless the input was overloaded, the typical failure is the 5060-0342 push rod assembly. Check the O rings
By
Kenneth Harrison <bibpakak507@...>
·
#133366
·
|
Re: Fixed my HP 5345A today!!
I am 72. I pulled a Hammarlund SP-600 of the shelf to test and could not get a sound out of it. I went so far as to hook a signal generator to it and started tracing the signal through the unit.
By
PAUL KOBY
·
#133365
·
|
Re: Fixed my HP 5345A today!!
As I reach 70 its becoming clearer that I will age out before I get to all the HP and Tek gear on the ¡°to repair¡± shelves in my shop. ?I do appreciate the ¡°smells¡± ?of the boat anchor tube
By
Dave - KO4AMB
·
#133364
·
|
Fixed my HP 5345A today!!
Every few months I like to fire up the seldom used HP gear on the workbench.? I really love listening to the Pratt and Whitney jet engines used to cool my HP 8345A.? Being elderly and getting deafer
By
commquart
·
#133363
·
|
Re: low amplitude readings below 10MHz on a 8591E
Hi in your case from 238-247 if you haven¡¯t done it already ..201 onwards backing up correction constants One thing to check is the level of your LO feedthrough amplitude ..the signal at 0hz on the
By
Mike Lockley
·
#133362
·
|
Re: low amplitude readings below 10MHz on a 8591E
got it and will start reading. Any recommendations about what paragraph? Gr Kees Op za 18 mrt 2023 om 18:19 schreef Mike Lockley via groups.io <mikelockley= [email protected]>:
By
KeesHofwegen
·
#133361
·
|
Re: low amplitude readings below 10MHz on a 8591E
You need 08590-90316 from 2001 8590 series Service Guide Are large tome but worth downloading or buying Regard¡¯s Mike g4wam Sent: 18 March 2023 14:41 To: [email protected]
By
Mike Lockley
·
#133360
·
|
Re: low amplitude readings below 10MHz on a 8591E
Hi, Are we talking about the user manual 08590-90301, because there is not much cal data in it other than the normal stuff. I also have the installation, verification & Operation manual. Or are there
By
KeesHofwegen
·
#133359
·
|
Re: low amplitude readings below 10MHz on a 8591E
This is now leaning towards a YTO failure¡ªnot good. Definitely do the CAL tests as per the user guide though Mike Sent: 18 March 2023 12:49 To: [email protected] Subject: Re:
By
Mike Lockley
·
#133358
·
|
Re: low amplitude readings below 10MHz on a 8591E
Hi, for laughs and giggles I just did a new cal and now I got a GAIN FAIL op the AMPTD. Gr Kees Op za 18 mrt 2023 om 11:11 schreef Mike Lockley via groups.io <mikelockley= [email protected]>:
By
KeesHofwegen
·
#133357
·
|
Re: HP 8656B display issue
Video of what¡¯s happening? https://youtu.be/JLgLmBeL2mg ( https://youtu.be/JLgLmBeL2mg )
By
KB2LMN
·
#133356
·
|
Re: low amplitude readings below 10MHz on a 8591E
Just a thought - started with my 8591E losing low end cal signal response with remaining good readings on the high end.? It was the result of a dying YIG.? Started out initially slowly but gradually
By
wa4whl@...
·
#133355
·
|
Re: Looking for a feedthrough capacitor
I posted my inquirey on the Wavetek side as well, with some more pics: /g/Wavetek-test-equipment/topic/97629517#69 Its more on-topic there (Wavetek bought W&G), but a lot less folks
By
Martin
·
#133354
·
|
Re: low amplitude readings below 10MHz on a 8591E
Hi there, The key to this is that the problem is below 10mhz. The first calibration point is at 12mhz. From what I remember the FM coil in the YTO does the below 10mhz steps. The main coil in the YTO
By
Mike Lockley
·
#133353
·
|
Re: HP 312A wave analyser
Right. The problem is that there are no photocells in today¡¯s equipment, so even googling for ¡°photocell¡± gives you results for ¡°photoresistor¡± (= LDR, Light-dependent resistor) [1]. Common
By
Carsten Bormann
·
#133352
·
|
Re: HP 312A wave analyser
Brad, that rather sounds like an LDR than a photocell to me. You can find them very cheap on eB in different types and sizes. Just give it a try and let us know... Chris
By
ChrisBeee
·
#133351
·
|