Re: copy of the 8402A power meter calibrator manual?
Thanks for the
responses, guys. And the Artek manual is on order.? Don't know
when I'll get around to needing it, but like anything on the
internet, b est to buy things when they are available.
John??? KK6IL
On 4/11/2025 11:56 AM, factory via
groups.io wrote:
toggle quoted message
Show quoted text
ArtekManuals list a 8402A operating/service manual, part
number 08402-902
?
David
|
Re: HP - a summary of what went wrong.
Carly Fiorina (where is she now?) did exactly what the Board of Directors TOLD her to do...no more-no less.
On Saturday, April 12, 2025 at 04:53:35 PM PDT, RFI-EMI-GUY <rhyolite@...> wrote:
|
Re: HP - a summary of what went wrong.
|
Re: HP - a summary of what went wrong.
Hi Don,
At first I thought you were referring to the years I was at HP (77-2002).? Things were fell apart on the instrument side at that time as well.??
I enjoyed working in the customer service center where it was a full repair and cal operation.? ?We could fix everything to the component level.? ? ?Rarely was a board replaced.??Then the instruments became assy level repair.? The 8753 was the first one that I recall but there were others like the 8920 etc.? ?Also fixed prices were established some where in there.? ? ? There was a fixed price for a repair, repair and cal and just cal and also a mini-repair price if the issue was very simple.? ? The cost of the assys were crazy.? ? Component level repair was no longer possible.? ?
Then the rep/cal facility became a cal only "hub".? ?If a repair was needed the instrument was shipped to Roseville, CA.? ? Also an on-site calibration service began.? ? The on-site cal work was too much like the stuff I hated to do in the air force were we traveled hours to get to a site and hours to get back to the base and 8 hours on the site.? Having to stay in a hotel away from home was not for me.? ? I hung on for a few more years in the power supply division.? ?After I left the power supply division,? the ex-repair / cal-only center was shut down and moved to PA and the entire facility was sold off.? The power supply div engineering / marketing dept moved somewhere close by and manufacturing was moved off-shore.? ?
Pete? ? ?
|
Re: HP - a summary of what went wrong.
Hi Don:
In my mind the real HP is Agilent/Keysight.? The company called HP is the computer spin off.
-- Have Fun,
Brooke Clarke
axioms: 1. The extent to which you can fix or improve something will be limited by how well you understand how it works. 2. Everybody, with no exceptions, holds false beliefs.
|
HP - a summary of what went wrong.
Please check this link for a description of a breakdown of HP’s process to destroying a great company.
?
|
Re: Looking for the manual for the HP H04-3460B or 3460B opt H04
Thanks David, I truly appreciate this.? Now maybe I can get it back up and running again.
Richard Parrish
toggle quoted message
Show quoted text
As requested I've scanned the "Modifications specification for the H04-3460A Digital Voltmeter", this is used with the standard 3460A manual part number 03460-90001 (not scanned as it's already available
from ArtekManuals), I've cleaned the pages a bit and added a pdf here;
?
Hope this helps.
?
David
|
Re: copy of the 8402A power meter calibrator manual?
ArtekManuals list a 8402A operating/service manual, part number 08402-902
?
David
|
copy of the 8402A power meter calibrator manual?
On 4/11/25 11:11, John Kolb wrote: Anyone know where I can find a copy of the 8402A power meter calibrator manual? has the manual without schematics, and I found those somewhere, and here they are:
|
Re: A homemade diode power sensor for HP meters
On 4/11/25 11:11, John Kolb wrote: Anyone know where I can find a copy of the 8402A power meter calibrator manual? I have an army tech bulletin on it. TB 9-4931-393-35 TB 9-4931-393-24
|
Re: A homemade diode power sensor for HP meters
Chased down reference #2 in the HP 1975-10 file
P. A. Szente, S. Adam, and R.B. Riley, "Low-Barrier..."
It's cited many places including this large publication:
An Introduction to Microwave Measurements
|
Re: A homemade diode power sensor for HP meters
Reading this thread reminded me of my 431 & 432. Anyone know
where I can find a copy of the 8402A power meter calibrator
manual? Not at the usual suspects.
John??? KK6IL
On 4/10/2025 10:10 AM, David Feldman
via groups.io wrote:
toggle quoted message
Show quoted text
I went back to the start of the thread to capture local copies of the various cited references. Most of the links are dead, however, internet archive wayback machine got me to almost all of them, so I have the files cached here now (mostly commercial reference material from HP and Boonton, along with Tobias' hand drawn schematics (I don't believe Tobias published schematics after his first few drafts, and don't know if he maintains a repository anywhere.)
|
Re: A homemade diode power sensor for HP meters
|
Re: Looking for the manual for the HP H04-3460B or 3460B opt H04
As requested I've scanned the "Modifications specification for the H04-3460A Digital Voltmeter", this is used with the standard 3460A manual part number 03460-90001 (not scanned as it's already available from ArtekManuals), I've cleaned the pages a bit and added a pdf here;
?
Hope this helps.
?
David
|
Re: A homemade diode power sensor for HP meters
Hi Sergey, Many institutions have recently decided that they need to know the location of their customers. For those that are ignorant about internet fraud, using Microsoft and Apple products, out-of-the-box, suffices, as they will all blab everything they know about you to anyone that asks during a web connection. Those with moderate knowledge of such things often use a variety of nonsense blockers that abort such requests for location as a matter of course... or spoof them, giving a random location. Those that use VNC, are skipped around the world until they are virtually at another location, so any information their browsers give is someone elses. Brave is particularly bad in this regard, as it dutifully blocks or spoofs just about everything asked that might identify you and your location... So, unless you give a little, most of commerce will ignore you, and you will be as lonely as the lighthouse keeper on the edge of the universe... I find I have to allow brave to give my location, for certain transactions, or they fail to work for me. -Chuck Harris On Wed, 9 Apr 2025 14:45:20 -0700 (PDT) "Sergey Kubushyn" <ksi@...> wrote: On Wed, 9 Apr 2025, Sergey Kubushyn wrote:
BTW, it also depends on where you are as everything is going via some proxy (CDN) like Akamai/Imperva/Cloudfare/whatever these days and those are falling apart.
There was couple of weeks when I was not even able to login into my Cox Business account to pay my bill -- it's been telling me I'm trying to login from abroad (they used/use Imperva and that routed me via Israel) and they don't allow that.
On Wed, 9 Apr 2025, Lynn C via groups.io wrote:
You were lucky to catch that very rare moment it worked. I don't need those connectors much -- have a bunch of dead sensors that I can use to build my own calibrator and those already have the entire driving circuitry in them so I don't have to build it from scratch. Just tried to get some to have them in stock, just in case. I actually don't see any other use for them except building a calibrator so not a big loss...
I just purchased 12 pcs without difficulty using a credit card for payment.
Lynn C. KA7FPH
On Wed, Apr 9, 2025 at 3:03?PM Sergey Kubushyn via groups.io <ksi= [email protected]> wrote:
On Wed, 9 Apr 2025, David Feldman via groups.io wrote:
They were $4.12 when I added 10 to my cart. Then, when tried to checkout they suddenly became $9.15 and "We can't process Credit Crd payments at this time. Please try again later".
Newark became a buggy horror, I was not been able to purchase ANYTHING from them for last 2 years or so -- there was ALWAYS an issue and their site never worked since something like couple of years ago.
Do NOT buy anything from them, don't support the incompetence.
This is about the Amphenol Tuchel female connector discussed in this thread's history (used by HP for panel and device mounting the 8480 series power sensors and 43x series power meters.)
This posting (9 April 2025) probably has limited utility and will at some point become moot, but wanted pass this along in case anyone was interested in homebrewing HP power sensor or power meter, as the ebay listing (offering the same connector) cited previously in the thread disappeared some time ago.
I located stock (in US distributor Newark) a version of the female panel connector cited in the discussion thread. They appear to be a "close out" (from time to time, Newark reprices an item in what appears to be an end-of-stock circumstance (the notation includes "available in quantity shown".)
This connector is female, panel mount, with solder cup pins (12 pins.) There are other variants of the same connector type (solder pins, etc.)
The part appears to show stock of 82 pieces (in US) at price of USD 4.12 today 9 April 2025.
Amphenol-Sine has online a data catalog which includes mechanical drawings for this specific connector:
See page 22 for PCB layout applicable to the 12 pin thru-hole version (PNG captured from that page is attached).
I rotated the (above) drawing of the 12 pin connector by 37.5 degrees counter-clockwise - using powerpoint - to bring the key down to the bottom of the connector, matching how it is used in the HP devices - and scaled it (pins E and K are separated by 9.0 mm) so that I could use the circles representing the 12 pins as a position guide for corresponding holes in a PC board layout (idea is a small PCB that adapts the connector's rear pins to a 2x4 2.54mm header for mating to a prototyping board.) Somewhat brute-force but this was a last-minute add to a PCB layout that was headed out for fab.
I ordered and received a couple of these connectors and they appear to mate with the typical HP sensor cable without difficulty. The panel mounting nut (ring) - included - would require a 2-pin hand tool to tighten.
I have a similar question as most-recent posting to this thread asked - about whether this project got built and what the experience was!
Dave
--- * * KSI@home KOI8 Net < > The impossible we do immediately. * * Las Vegas NV, USA < > Miracles require 24-hour notice. * *
|
Re: A homemade diode power sensor for HP meters
The files are in a folder called
A homemade diode power sensor for HP meters 92636
|
Re: A homemade diode power sensor for HP meters
Files (8) are uploaded. They used the names given by the original link.
|
Added Folder /All HP, Agilent and Keysight instruments in folders by part numbers/8000 to 8999/8481A, 8482A and 8483A Power Sensors/A homemade diode power sensor for HP meters 92636
#file-notice
David Feldman <wb0gaz@...> added folder /All HP, Agilent and Keysight instruments in folders by part numbers/8000 to 8999/8481A, 8482A and 8483A Power Sensors/A homemade diode power sensor for HP meters 92636
Description:
Files referenced in thread that started Feb 1 2019. Retrieved using Internet Archive Wayback machine.
|
Re: The care of RF connectors
Aside from HP and Mini Circuits there are numerous other documents available from other sources talking about his subject.
I used to attend seminars at NBS (now NIST) when living in Boulder, Colorado Some of them touched on connector characteristics and care. I was surprised to learn about the limited number of mate/unmate cycles on some connectors before they degraded the signals passing through them.
Greg
|
Re: A homemade diode power sensor for HP meters
How about this location:
David, thanks for collecting these files.? I was not able to collect the files from the now-broken references so I appreciate your efforts.
Lynn C.
toggle quoted message
Show quoted text
Solder-tail version of the same connector, also from Newark, also at unusual unit price.
Roy - if this is contrary to group guidelines, please accept my apology (I presumed that this would be of interest due to the very specialized nature of the parts and the prior reference to an ebay seller being defunct.)
Below is a listing of the file names I retrieved using internet archive during my brief review of the thread this morning (anyone could do this, but of course it will be convenient to have them cached online).
I've not uploaded them anywhere at this point - they can be retrieved using internet archive to search on each of the (defunct) URLs that were in the postings from earlier times.
If someone can tell me where these files should be uploaded, I'll be happy to do that.
(DOS command of the directory where I put the files retrieved)
Directory of D:\848x homebrew power sensor
04/10/2025? 05:22 PM? ? <DIR>? ? ? ? ? .
04/10/2025? 05:22 PM? ? <DIR>? ? ? ? ? ..
04/10/2025? 10:54 AM? ? ? ? ?2,658,520? ? ? ? ? ? ? ? ?08484-90019-PowerSensor.pdf
04/10/2025? 11:01 AM? ? ? ? ?5,261,326? ? ? ? ? ? ? ? 1975-10.pdf
04/10/2025? 10:51 AM? ? ? ? ?4,021,004? ? ? ? ? ? ? ? 20181117_170657.jpg
04/10/2025? 10:50 AM? ? ? ? ?3,350,675? ? ? ? ? ? ? ? 20181117_173101.jpg
04/10/2025? 10:52 AM? ? ? ? ? ?234,284? ? ? ? ? ? ? ? ?8481schem.png
04/10/2025? 10:55 AM? ? ? ? 11,393,180? ? ? ? ? ? ? ?8484a.pdf
04/10/2025? 10:56 AM? ? ? ? ? ?211,615? ? ? ? ? ? ? ? HP 11683A H01 ops_service.pdf
04/10/2025? 11:03 AM? ? ? ? ?6,653,962? ? ? ? ? ? ? ?WTG_RefGuide_F1128_sm_web.pdf
|