¿ªÔÆÌåÓý

Date
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Ken, I found 1, 2, and 3. They were all good. Where do I find the "verbal feedback" option at? Also are you saying to remove the grain of wheat bulb? I also have gone back to 4.12 version. I have also
By cwt2168@... · #150330 ·
Locked Upgrade from 4.11.2 to 4.12 failed
I have upgraded many times without problems, but my latest upgrade has failed. I am running on a Toshiba C655, Win 10, Java 8 181, with a Locobuffer USB connected to a Digitrax DCS 200. No error
By diesele645@... · #150329 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on Loksound and Broadway Limited decoders. I can read the digitrax decoders.
Hi Try a resistor between 500 and 2k ohms for Lenz, tcs. The value of the resistor matters. The BLI decoders need the audio feed back disabled. Steve G.
By Steve_G · #150328 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on Loksound and Broadway Limited decoders. I can read the digitrax decoders.
I just bought 5 emd locos from broadway limited. They are the new sound decoders something3 Jmri will not identify the decoder on a random basis. Try selecting the decoder from the list and write a
By AD · #150327 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on Loksound and Broadway Limited decoders. I can read the digitrax decoders.
I was never able to consistently read TCS, Lenz and NCE N-scale decoders with an original Zephyr, either direct from the command station, or with DecoderPro running on a Linux laptop connected with a
By Russ Brodfuhrer · #150326 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Cwt, First I'd suggest you stick with 4.12, there are issues in 4.10 that are likely to bite you sometime. Next, make sure you can select if you use the PowerPax and select to disconnect the grain of
By Ken Cameron · #150325 ·
Locked I am unable to read what type of decoder from the program track and mainline on Loksound and Broadway Limited decoders. I can read the digitrax decoders.
I am using version 4.10 and have tried 4.12 JMRI on windows 10. I also am using a RR-CirKits LocoBuffer-USB version 3 on com port 3, a Digitrax DCS 200 and a program booster (PowerPax) to the program
By cwt2168@... · #150324 ·
Locked Re: Turnout minor issue
Thanks Steve Yes I did that and all are well now, regards Manos SV1IW
By Manos Darkadakis <sv1iw@...> · #150323 ·
Locked Re: Turnout minor issue
Hi Manos You saved them: tools->file->save->save configurations only to file. Then to load: Panels->Open Panels Steve G.
By Steve_G · #150322 ·
Locked Re: Turnout minor issue
Thanks again Ken, got them all sorted out, so far. If I load the tables from panel menu (had them saved with a different name) all return as expected. The reason I didn't do this before is that
By Manos Darkadakis <sv1iw@...> · #150321 ·
Locked Re: Loconet Monitor Startup
John, What you are seeing is one of two things. First it could be the command station. When it does a power on to the track, it sends special commands (what you see) to ask all devices on the layout
By Ken Cameron · #150320 ·
Locked Re: Loconet Monitor Startup
JMRI is querying for the status of devices connecting to the LocoNet. But for some reason, perhaps because layout power is off, the command station is rejecting the requests (that¡¯s the ¡°Switch
By Bob Jacobsen · #150319 ·
Locked Loconet Monitor Startup
If I have JMRI running on my computer and then plug it into my Digitrax command station this comes across the loconet monitor screen (just a sample of the full trace) Interrogate LocoNet
By John Griffin · #150318 ·
Locked Re: L1USB Ethernet Adapter Error ? Help
Hi Paul, ?? I mentioned in an earlier message that I hadn't been able to recover a largely working layout from a number of changes and updates etc., most of which were relatively minor, however it
By Alan Gibbs · #150317 ·
Locked Re: Signal Mast - Mast Driver - Output Matrix
I recall someplace (so usefull I know) a toggle to put a delay between throwing turnouts. It sounds like this could be enabled. [email protected]> wrote:
By Spuds McCat · #150316 ·
Locked Re: Capability of Decoderd/Panel Pro
Assuming that the engines always run together. Set both to run headlights based on consist address. Set both to never turn reverse headlight on. If you're worrying about horns/bells, etc
By Spuds McCat · #150315 ·
Locked Re: Cannot edit problem turnouts
Hi Dave All these items you have come up with were caused I think by me following the suggestion in the Check menu as mentioned previously. I think I will have a look through my backup files and find
By Fraser Smith · #150314 ·
Locked Re: Signal Mast - Mast Driver - Output Matrix
Option Reset previous Aspect does not affect the result. When I switch the turnouts from the Turnout Table, there is no delays. *07:05:05.726* : [packet: 52 1A 88 C0]? Accessory Decoder Operations
By Petr ?¨ªdlo · #150313 ·
Locked Re: Turnout minor issue
Manos, Ok, here is a few quick clues. First if you do a save in the tables, it creates a file that is same as if you did Panels->Save Panel, but the tables only saves the table items. I always use
By Ken Cameron · #150312 ·
Locked Re: Turnout minor issue
Hi Ken, I did save the parameters but could not find a way to reload from the same menu (tools->tables->turnouts). Reloading was my first thought but I guess this happens from the startup of the
By Manos Darkadakis <sv1iw@...> · #150311 ·