URC MX980 wont work with my STRFGWX

 

So i bought a URC MX980 and was thinking since the STRFGWX is 418mhz it would work as the receiver.

Am i wrong? I cant drop it in on the symbol... WTH?

and i have another gateway but yep it is a CNRFGWA... that is 418mhz.

so am i screwed?


please understand, i am a commercial guy we do not do allot of handheled remotes..


Weird Network issues between Crestron products as of late?

 

Has anyone else experience weird network connection problems between Crestron equipment with recent updates?

I have had DM Router issues, where it will show the DM Router as being offline until I reboot the DM and then it pops back up online in the IP Table.

This happened in multiple locations with multiple programs/DMs.

On another site I have CP2E running lights talking to another CP2E and I'm having a hell of a time getting them to talk to each other over an EISC.

A reboot of both will usually connect them up for a while, but then they will stop talking.

One processor is showing a status of "UNKNOWN" and the other shows a connection status of "NO_NETWORK", which I don't remember seeing before.

I gave up using Direct Sockets because they seem broke, but this is just basic Crestron 101 falling apart.


Re: Going mad... xPanel

 

Ok, I tried it on a new PC and it shows the new design, but on the PC's which have already run the older design it doesn't update, so I guess this is an IE cache problem rather than Crestron - never seen it before tho!

--- In Crestron@..., "rlf79cm" <rlf79cm@...> wrote:

Tried that, both with the IE options and CCleaner to clear everything - still showing old design :o(

--- In Crestron@..., trayschaeffer <trayschaeffer@> wrote:

Clear the temp files from your browser. That's all I can think of right now...

Tray




Sent from my Samsung Galaxy Note???, an AT&T LTE smartphonerlf79cm <rlf79cm@> wrote:
I've updated my xPanel but whenever I compile and run it through the browser it's showing the old version - I've tried renaming, running it from the PC, processor, etc - always showing the old version. If I compile as an exe the new design works fine, but I can't for the life of me get the browser version to update.

Never seen this before - any ideas?

Cheers, Rick



[Non-text portions of this message have been removed]


Re: Going mad... xPanel

 

Tried that, both with the IE options and CCleaner to clear everything - still showing old design :o(

--- In Crestron@..., trayschaeffer <trayschaeffer@...> wrote:

Clear the temp files from your browser. That's all I can think of right now...

Tray




Sent from my Samsung Galaxy Note???, an AT&T LTE smartphonerlf79cm <rlf79cm@...> wrote:
I've updated my xPanel but whenever I compile and run it through the browser it's showing the old version - I've tried renaming, running it from the PC, processor, etc - always showing the old version. If I compile as an exe the new design works fine, but I can't for the life of me get the browser version to update.

Never seen this before - any ideas?

Cheers, Rick





Re: Going mad... xPanel

 

Clear the temp files from your browser. That's all I can think of right now...

Tray




Sent from my Samsung Galaxy Note?, an AT&T LTE smartphonerlf79cm <rlf79cm@...> wrote:
I've updated my xPanel but whenever I compile and run it through the browser it's showing the old version - I've tried renaming, running it from the PC, processor, etc - always showing the old version. If I compile as an exe the new design works fine, but I can't for the life of me get the browser version to update.

Never seen this before - any ideas?

Cheers, Rick



[Non-text portions of this message have been removed]


Going mad... xPanel

 

I've updated my xPanel but whenever I compile and run it through the browser it's showing the old version - I've tried renaming, running it from the PC, processor, etc - always showing the old version. If I compile as an exe the new design works fine, but I can't for the life of me get the browser version to update.

Never seen this before - any ideas?

Cheers, Rick


Naim NS02 Server

 

Hi all
Can anyone please help?? with an issue on the Naim NS02 server module (just uploaded this to the files section)
This module was working fine until the latest Crestron and device database updates, Now when I try and run the program I get a loop error, see below. I have tried re compiling the SIMPL+ and no errors show up, however as soon as I initiate the "now playing_but" of the module it puts a loop of data into the program with the following error message:

09:03:00 - 03-08-2013: TOD$ -> 030820130902590000
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1434: Integer Array STDATASTRUCT__IEXTTIERSEARCHISACTIVE overflow. Col = 65511. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1435: Integer Array STDATASTRUCT__ITIERSEARCHISACTIVE overflow. Col = 65511. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1434: Integer Array STDATASTRUCT__IEXTTIERSEARCHISACTIVE overflow. Col = 65510. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1435: Integer Array STDATASTRUCT__ITIERSEARCHISACTIVE overflow. Col = 65510. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1434: Integer Array STDATASTRUCT__IEXTTIERSEARCHISACTIVE overflow. Col = 65509. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1435: Integer Array STDATASTRUCT__ITIERSEARCHISACTIVE overflow. Col = 65509. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1434: Integer Array STDATASTRUCT__IEXTTIERSEARCHISACTIVE overflow. Col = 65508. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1435: Integer Array STDATASTRUCT__ITIERSEARCHISACTIVE overflow. Col = 65508. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1434: Integer Array STDATASTRUCT__IEXTTIERSEARCHISACTIVE overflow. Col = 65507. Bounds = 8
09:03:00 - 03-08-2013: [Console Data] : Error: Module S-2.9.2.4:S-9 : S2_Naim_audio_server_sophia_processor at line 1435: Integer Array STDATASTRUCT__ITIERSEARCHISACTIVE overflow. Col = 65507. Bounds = 8


New file uploaded to Crestron

 

Hello,

This email message is a notification to let you know that
a file has been uploaded to the Files area of the Crestron
group.

File : /Modules/Naim audio server module.zip
Uploaded by : johnuksmarthome <john@...>
Description : Naim NS02 Server

You can access this file at the URL:


To learn more about file sharing for your group, please visit:

Regards,

johnuksmarthome <john@...>


Re: DMPS100

 

yes, u tried but nothing happened still disconnected

plzzzz help

--- In Crestron@..., Rapha?l Thiffault <raphaelthiffault@...> wrote:

your first ip table is 127.0.0.1 is it a type mismatch ?

have you set the same ip-id on the dmps and the tp ?


{Paf}


2013/3/21 wes <wesam_helmy@...>

**


i have DMPS100 & TPMC12v screen
the screen disconnected i don't know the reason

DMPS IP: 192.168.1.62. IP TABLE: 172.0.0.1
TP IP: 192.168.1.93. IP TABLE: 192.168.1.62

is this correct configuration?



[Non-text portions of this message have been removed]


Re: Tandberg Buffer Overflow error

 

You are correct that the module I am referencing is the 'Tandberg MXP Processor v1 (cm)'. Tried increasing the buffer size a few times, and still would not fix it. In the case of the Tandberg making connections with multiple sites (10+) the Crestron processor would wind up rebooting due to the amount of data it was getting from the Tandberg, combined with the inefficient SIMPL+.

Wound up writing my own code to get feedback, and since my competition was unable to do the same, I won myself a new customer :)

I will keep the suggestions you made in mind though, if I revisit that project.

--- In Crestron@..., "Steve Kaudle" <skaudle@...> wrote:

I'm assuming the log entries you've included are from the Simpl+ module
'Tandberg MXP Processor v1 (cm)'.



Adding a ClearBuffer is rarely a good solution to a buffer overflow. I'd
suggest one of two things:



Make the buffer bigger. This isn't anything like a sure-fire solution, but
it's easily accomplished. This really only works when a module that will
always, eventually process (and remove) all data from its buffer is
overwhelmed with a lot of data in a very short period of time.



Make sure the module is configured in such a way that all data will always
be processed (and removed) from the buffer, regardless of the timing of its
arrival.



The Simpl+ in question appears to be written in such a way that the contents
of the buffer, assuming all data is delimited with a New Line, will
eventually be processed regardless of timing. I'm not a big fan of the
specific method used* but in and of itself, it should function as intended.
My guess, is this is one of those somewhat rare instances where making the
buffer bigger might actually pay off.



*More than a few bits of the logic inside the TandbergRx$ Change could be
rewritten to make life easier for both the programmer and the processor, but
you'd have to give up X-Gen compatibility along the way.



From: Crestron@... [mailto:Crestron@...] On Behalf
Of coolaiddrinker
Sent: Friday, March 22, 2013 10:53 AM
To: Crestron@...
Subject: [Crestron] Tandberg Buffer Overflow error





Hi Guys,

I am starting to get buffer overflow issues from Tandberg MXP Full Control
module (crestron written). I opened the module to see where the issue is
indicated, I can see they have put remove command so technically the buffer
shouldn't overflow. Should I just put a clearbuffer command at the end of
change event to rid me of this issue.

here is what i am receiving in the error logs

ystem log:

1. Notice: CIP device 12: back ONLINE
TimeStamp: 20:23:56 3-20-13 UpTime: 0 days 00:01:08.15 Task: UDP_Serv
2. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1007, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.36 Task: EvD0004
3. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1021, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.39 Task: EvD0004
4. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1022, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.41 Task: EvD0004
5. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1011, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.43 Task: EvD0004
6. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.44 Task: EvD0004
7. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1013, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.46 Task: EvD0004
8. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1002, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.48 Task: EvD0004
9. Error: Overflow on Buffer Input __TANDBERGRX$ on Module: S-3.3:S-32. New
= 1024, Max = 1000
TimeStamp: 20:28:35 3-20-13 UpTime: 0 days 00:05:48.58 Task: EvD0004
Total Errors Logged = 9

just for curiosity, how do you guys fix these issues as i experience them
with clearone/Biamp(sometimes) modules and some others(all crestron modules)
as well?

Thanks in advance.







volume feedback from pioneer elite VSX-91TXH

cheinemann605
 

I am having some trouble using the volume feedback from this receiver to drive a analog gauge. With other devices, I use a lookup table in the serial i/o to drive an analog initialize, and an analog scaler. But, this unit does not respond with vol xx. Instead this receiver feeds back with :

v
o
l
x
x

each character is fed back with a carriage return after it. Is there some type of counter or accumulator that could take these numbers and combine them together into a single string?? I thought of using the numeric keypad, but once 2 bits are sent, then the keypad logic would have to be reset every time. My guess is that someone has had to deal with this issue before.


Re: Relay Speaker Switching

 

Sorry I missed your reply, been away for a few days, thanks very much for the info, will wire it up and give it a go!!

P

--- In Crestron@..., Heath Volmer <hvolmer@...> wrote:

Sounds like it will be fine.

Heath Volmer
Digital Domain Systems
Littleton, CO

Sent from my iTypo 4

On Mar 19, 2013, at 11:02 PM, "pd.armstrong77" <paul_mach3@...> wrote:

but I could potentially use a din-8sw8 relay for the switching? its rated for 240v 16amp. I only ask as I am using these for all sorts of requirements on site from window treatments and garage door open triggers etc and I have plenty of spares on the last module? I could trigger it from the selection of the altered tv position with an interlock?

--- In Crestron@..., Heath Volmer <hvolmer@> wrote:

You can use the PRO3 relays to trip an external relay. I like to get relays with 24V DC coils because there is always Cresnet power around. Any time you introduce a contact into a speaker line, you could have loss, but it will be negligible and probably undetectable.

I believe the internal relays are rated for 30V. Speakers signal can exceed that. Not sure what would happen, given the transient nature of the signal. You would of course use up four of them vs just one for external and it will be messier than using a DPDT relay external (looping the inputs through those tiny terminals). It is always safest to have a level of separation between things. I recall taking over a job with a PRO2 that had many fried relays. There was a motorized door panel that had a 48V trigger on an external relay. I'm assuming that the previous guy had tried various internal relays and had relay failures. I think they were stuck closed.

- Heath -

On Mar 17, 2013, at 10:00 PM, pd.armstrong77 wrote:

what a fantastic suggestion! and a tremendous price!! Will there be any loss of quality?

When you say digital output, are you referring to the pro3 versiports? Can they be set to output a specific voltage or will this toy be happy with a logic closure?

Out of curiosity what is the reason that their relays can't be used, would it damage them? or the speakers, or both?


[Non-text portions of this message have been removed]

[Non-text portions of this message have been removed]


Re: Oppo BDP-103 no video

 

A couple of obvious things...
1) Make sure you're using one of the HDMI outputs on the Oppo, not the
input.
2) Try both HDMI outputs on the Oppo - HDMI 2 has a less complex signal
path and thus quicker HDMI handshakes.
3) Try the Oppo connected directly to a display, bypassing the HD-MD8x1 to
rule out a defective Oppo.

Geoff

On Saturday, March 23, 2013, innoventgroup wrote:

**


Can anyone please help. I have a Newly Installed Oppo BDP-103 installed
behind a HD-MD8x1 and I cant get it to provide a signal via the HDMI. Any
suggestions... what am I doing wrong...



[Non-text portions of this message have been removed]


Oppo BDP-103 no video

innoventgroup
 

Can anyone please help. I have a Newly Installed Oppo BDP-103 installed behind a HD-MD8x1 and I cant get it to provide a signal via the HDMI. Any suggestions... what am I doing wrong...


Re: TSW series a lot to learn and ask...

Eric Williams
 

Lots of improvements. Now uses a TCP IP symbol for connection and won't throw any errors. Makes it easier to handle when and why it connects. Make sure to update the ra 2 firmware to the newest.

Eric Williams
ABE Networks
240-604-4771

On Mar 23, 2013, at 1:04 PM, "Jesus @ Audio& Net Artist" <audioandnetartist@...> wrote:

Did they released V5? I used last week V4 on RA2 modules, came out really
good! any improvements?

--
*Jesus Tossas*
*
*
*Technology Architect, Audio Engineer, Programmer*
*
*
*787-460-1223*
*
*
Contact Info <>




[Non-text portions of this message have been removed]


Re: On Site - AV2 not responding

 

I had a similar issue with a AV2 and the simpl+ modules that I was using from BSS would lock it every time. I could load the same program to a cp2e at work and it would work fine, both had v4.003 firmwares. That AV2 had v1 firmware when I got to it and I updated it to v4.003.

They only way I could get the AV2 to come back to life was to connect to it 232 and hold software btn and press release HW btn and keep holding the software for about 10 seconds. Initialize and restore it from command prompt. I then had to change to older BSS modules and reload the program and all was good.

I think crestron changed something from the the first generation of pro/av2's to the current and the first generation does not like the simpl+

--- In Crestron@..., "RobK" <fooguy89@...> wrote:

Try booting up bypassing the program. You'd need to recompile the program that's in there (I thought they got erased on that major of an upgrade but maybe not) with the latest simpl + include4_2series.dat (in the latest database).

Program by pass = tap HW-R, then hold SW-R until you see the "bypassing program!" come up in the serial console (or just wait like a minute)

PS: since you have a serial console did you see ANYTHING after a HW-R...?



--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@> wrote:

Also, I have tried HW-R about 2 -3 times with no success.

--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@> wrote:

Hi Guys,

I am currently on a site where I tried to load a new project in AV2 that had firm rev 3.137 and system kept rebooting itself. So I performed SW-R to bypass the program and then upgraded the firmware to v4.003 but now i can't connect to the processor at all. The update was done through serial cable and trying to connect to it via serial as well.

When attempting to connect to processor, i get a warning in toolbox saying "the ability requested (code = productverfiypresence) is not supported on the device.


Any suggestions?

TIA


Re: On Site - AV2 not responding

 

What about text console and try init and reboot then reload current program?
On Mar 23, 2013, at 4:26 PM, "RobK" <fooguy89@...> wrote:

Try booting up bypassing the program. You'd need to recompile the program that's in there (I thought they got erased on that major of an upgrade but maybe not) with the latest simpl + include4_2series.dat (in the latest database).

Program by pass = tap HW-R, then hold SW-R until you see the "bypassing program!" come up in the serial console (or just wait like a minute)

PS: since you have a serial console did you see ANYTHING after a HW-R...?

--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@...> wrote:

Also, I have tried HW-R about 2 -3 times with no success.

--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@> wrote:

Hi Guys,

I am currently on a site where I tried to load a new project in AV2 that had firm rev 3.137 and system kept rebooting itself. So I performed SW-R to bypass the program and then upgraded the firmware to v4.003 but now i can't connect to the processor at all. The update was done through serial cable and trying to connect to it via serial as well.

When attempting to connect to processor, i get a warning in toolbox saying "the ability requested (code = productverfiypresence) is not supported on the device.


Any suggestions?

TIA

[Non-text portions of this message have been removed]


Re: OT: what to do with TiVo Series 1 box?

Heather Baiman
 

I just brought my useless ReplayTV to Best Buy two weeks ago, they have recycling programs. Just need to check their website for your area.
________________________________________
From: Crestron@... [Crestron@...] on behalf of RobK [fooguy89@...]
Sent: Saturday, March 23, 2013 4:30 PM
To: Crestron@...
Subject: [Crestron] Re: OT: what to do with TiVo Series 1 box?

I sympathize with OP, I hate throwing out what was once useful and I see it as still maybe useful. It was painful when I upgraded my Replay series 5000 boxes to Tivo Series 3 HD's... I kept them for a while thinking someone might want them, but couldn't find anyone. Went to the dump. At least OP was able to transfer his license out.

Rather than put it curbside, I'd at bring it to your town's local recycling center, most towns seem to have some kind of "e-waste" container these days. If not, find a friend who has one and get him to toss it.

If you really want to try to get rid of it, try freecycle or Craiglist.


--- In Crestron@..., "martinkup90" <martin@...> wrote:

How about using it as a chair warmer?

--- In Crestron@..., Geoffrey Reynolds <greynlds@> wrote:

The door stop option sounds like the best use for those at this point :).

Geoff

On Sat, Mar 23, 2013 at 2:45 PM, Tony Golden <mrgolden@> wrote:

**


That's a good question, Joe. I actually have one Series 1 box and two
Series
2's sitting in my garage, that I've also been hesitant to just "throw
away".

A quick Google search didn't really turn up any great ideas...

--- On Saturday, March 23, 2013 at 12:36 PM, Joseph Vossen wrote:

I'm cleaning out a closet and came across a TiVo Series 1; I boxed it up
and transferred the license when I replaced it with a TiVo HD. I hate to
throw out useful electronics, does anyone have any ideas on what I can
use
this thing for other than a boat anchor and/or door stop? I'm open to
pretty much anything that is fun and (somewhat) useful.

thanks


[Non-text portions of this message have been removed]



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: OT: what to do with TiVo Series 1 box?

 

I sympathize with OP, I hate throwing out what was once useful and I see it as still maybe useful. It was painful when I upgraded my Replay series 5000 boxes to Tivo Series 3 HD's... I kept them for a while thinking someone might want them, but couldn't find anyone. Went to the dump. At least OP was able to transfer his license out.

Rather than put it curbside, I'd at bring it to your town's local recycling center, most towns seem to have some kind of "e-waste" container these days. If not, find a friend who has one and get him to toss it.

If you really want to try to get rid of it, try freecycle or Craiglist.

--- In Crestron@..., "martinkup90" <martin@...> wrote:

How about using it as a chair warmer?

--- In Crestron@..., Geoffrey Reynolds <greynlds@> wrote:

The door stop option sounds like the best use for those at this point :).

Geoff

On Sat, Mar 23, 2013 at 2:45 PM, Tony Golden <mrgolden@> wrote:

**


That's a good question, Joe. I actually have one Series 1 box and two
Series
2's sitting in my garage, that I've also been hesitant to just "throw
away".

A quick Google search didn't really turn up any great ideas...

--- On Saturday, March 23, 2013 at 12:36 PM, Joseph Vossen wrote:

I'm cleaning out a closet and came across a TiVo Series 1; I boxed it up
and transferred the license when I replaced it with a TiVo HD. I hate to
throw out useful electronics, does anyone have any ideas on what I can
use
this thing for other than a boat anchor and/or door stop? I'm open to
pretty much anything that is fun and (somewhat) useful.

thanks


[Non-text portions of this message have been removed]


Re: On Site - AV2 not responding

 

Try booting up bypassing the program. You'd need to recompile the program that's in there (I thought they got erased on that major of an upgrade but maybe not) with the latest simpl + include4_2series.dat (in the latest database).

Program by pass = tap HW-R, then hold SW-R until you see the "bypassing program!" come up in the serial console (or just wait like a minute)

PS: since you have a serial console did you see ANYTHING after a HW-R...?

--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@...> wrote:

Also, I have tried HW-R about 2 -3 times with no success.

--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@> wrote:

Hi Guys,

I am currently on a site where I tried to load a new project in AV2 that had firm rev 3.137 and system kept rebooting itself. So I performed SW-R to bypass the program and then upgraded the firmware to v4.003 but now i can't connect to the processor at all. The update was done through serial cable and trying to connect to it via serial as well.

When attempting to connect to processor, i get a warning in toolbox saying "the ability requested (code = productverfiypresence) is not supported on the device.


Any suggestions?

TIA