Re: My last 12 OSO's would not upload to Lotw
[email protected]> wrote: There is no such thing as an "Internet" QSO as far as logbook is concerned. However, IRLP and Echolink are allowed. Go figure. 73, -Rick -- Rick Murphy, D. Sc.,
By Rick Murphy · #228441 ·
Re: My last 12 OSO's would not upload to Lotw
+ AA6YQ comments below + The error message " Invalid prop mode (internet) on line 5 " came from TQSL when it was processing the QSOs that DXKeeper directed it to submit to LoTW - not from DXKeeper.
By Dave AA6YQ · #228440 ·
Re: IC-PW1 configuration in DXLabCommander
+ AA6YQ comments below A direct connection between transceiver and amplifier is not supported by DXLab Suite. If you are using that connection, please seek help from Icom or one of the Icom support
By Dave AA6YQ · #228439 ·
Re: My last 12 OSO's would not upload to Lotw
It was the propagation window. ?Somehow internet was in that window. ?I must have done that but did not realize it. ?Anyway all is well now. Thanks so much. Al ?KA9OUT
By Crispo, Alexander W · #228438 ·
Re: Prefix/Call not transferred to DXKeeper
+ AA6YQ comments below THANKS, I searched for that option and never saw it.... I made up that call as an example only. +
By Dave AA6YQ · #228437 ·
Re: IC-PW1 configuration in DXLabCommander
Attachments are not conveyed here due the limitations of the free list. A direct connection between transceiver and amplifier is not supported by DXLab Suite. If you are using that connection,
By Joe Subich, W4TV · #228436 ·
Re: Prefix/Call not transferred to DXKeeper
THANKS, I searched for that option and never saw it.... I made up that call as an example only. 73 Den
By Dennis Spiess · #228435 ·
Re: IC-PW1 configuration in DXLabCommander
Dave, W6DE As shown in the attached figure, the PC is connected to the IC-7600 and the IC-PW1. I cannot control IC-PW1 well in this condition. Shige,
By Shigeru Ohsawa · #228434 ·
Re: Prefix/Call not transferred to DXKeeper
+ AA6YQ comments below Double clicking a call in SpotCollector with a prefix/call sign eg. FY/X8WW shows up in the DXKeeper filter box as X8WW but.... does show up in Capture as FY/X8WW with the
By Dave AA6YQ · #228431 ·
Re: My last 12 OSO's would not upload to Lotw
+ AA6YQ comments below When I submit most requested I get a blank window. If I try to upload manually I get a message that no QSO's were submitted because some QSO's were already uploaded or invalid.
By Dave AA6YQ · #228430 ·
Re: IC-PW1 configuration in DXLabCommander
No, it is not. For DXLab Suite to control a PW-1 you must use the following configuration: <https://www.dxlabsuite.com/dxlabwiki/PW1Control> 73, ... Joe, W4TV
By Joe Subich, W4TV · #228429 ·
Re: IC-PW1 configuration in DXLabCommander
Dave, W6DE One is from IC-7600 (REMOTE terminal) to CT-18 to connect to PC. The other is to connect IC-7600 and PC with USB cable. Is this connection method not acceptable? Shige, JJ1BCM
By Shigeru Ohsawa · #228428 ·
Re: IC-PW1 configuration in DXLabCommander
Dave, W6DE I forgot to mention in my previous e-mail that I have set the menu “CI-V Transceive ON” on the IC-7600. Otherwise, IC-7600 cannot control IC-PW1. (It is written in the ICOM
By Shigeru Ohsawa · #228427 ·
Re: IC-PW1 configuration in DXLabCommander
You will need a second CIV connection path for DXLab Commander running in the computer to communicate with the PW1. Do you have a second CT-18 or other way to connect your computer to the PW1? See
By Dave w6de · #228426 ·
Re: IC-PW1 configuration in DXLabCommander
Now connect your computer to the 7600 and connect your CT-18 up to the 7600 and use DXLab Commander to control the 7600—still ignoring the PW1, don’t connect the 7600 to the PW1 with the accessory
By Dave w6de · #228425 ·
Re: IC-PW1 configuration in DXLabCommander
Thank you, Dave. IC-PW1 address at 74(DXLab's “Controlling an Icom PW1 Amplifier” instructs to set the address of IC-PW1 to 74.). IC-7600 address at 7A. IC-7600 controls IC-PW1
By Shigeru Ohsawa · #228424 ·
Re: IC-PW1 configuration in DXLabCommander
Leave the PW1 address at 71 and the 7600 address at 7A. Your serial number is high enough to allow standby pass through. Let’s try this again step by step. To ignore the computer and DXLab,
By Dave w6de · #228423 ·
Re: My last 12 OSO's would not upload to Lotw
LotW does not accept "QSOs" made on the internet. If you QSOs are truly internet QSOs you can not upload them. If they are not "internet" QSOs, correct the Mode in the Propagation panel of the Log
By Joe Subich, W4TV · #228422 ·
My last 12 OSO's would not upload to Lotw
When I submit most requested I get a blank window. If I try to upload manually I get a message that no QSO's were submitted because some QSO's were already uploaded or invalid. Of course checking Lotw
By Crispo, Alexander W · #228421 ·
Re: Missing Distances/Grids after carefully following distance computation procedure.
+# More AA6YQ comments below # A grid square determined by "geocoding" means that the grid square was "determined" from a postal address; I've appended Perplexity's explanation of this process below.
By Dave AA6YQ · #228420 ·