Re: IC-PW1 configuration in DXLabCommander


 

开云体育

You will need a second CIV connection path for DXLab Commander running in the computer to communicate with the PW1.? Do you have a second CT-18 or other way to connect your computer to the PW1??

See the connection diagram in this article.

?

73,

Dave, w6de

?

From: [email protected] <[email protected]> On Behalf Of ji8bxb.jj1bcm.shige via groups.io
Sent: 19 March, 2025 23:07
To: [email protected]
Subject: Re: [DXLab] IC-PW1 configuration in DXLabCommander

?

Thank you, Dave.

?

>Leave the PW1 address at 71 and the 7600 address at 7A.

IC-PW1 address at 74(DXLab's “Controlling an Icom PW1 Amplifier” instructs to set the address of IC-PW1 to 74.).

IC-7600 address at 7A.

?

>With the accessory cable and CIV cables directly connected between the PW1 and the 7600 can you successfully Sync the PW1 and 7600 together?

IC-7600 controls IC-PW1 perfectly.

?