开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育

Re: 120/240V switch?

 

Sorry, this group.io thing here doesn't display Apple's picture file format.? So, I converted it to JPEG and reattaching it to show the voltage selector switch of my LA-1K (Serial Number: 38935, delivered on January 21, 2023) indicates "230V" instead of the "240V" as explicitly stated in the LA-1K "WARNING" materials "TO SWITCH BETWEEN 120V AND 240V" that accompany each shipment.

73,
Ray
KJ5MI


Re: 120/240V switch?

 

Ron,

Ok, so rather than using electricity provided by your local power company, you are powering your LA-1K with two (2) of your own generators -- main and backup units to achieve 242VAC and 239VAC, respectively.

The Palstar "WARNING" thing, attached to your previous entry, says "TO SWITCH BETWEEN 120V AND 240V" but the voltage selector switch on my LA-1K says 230V instead, as shown in the pic attached to my entry here.? Maybe someone from Palstar corporate would kindly provide us the part number and name of the OEM of the current power supply for reference.

Hey no April Fools.. my brand new LA-1K experienced a power on/off switch malfunction within the first 30 calendar days of use.? The power switch, deemed defective by Palstar, required remove and replace actions to return the LA-1K to fully serviceable condition.? Perfect example of infant mortality!

Guess what.. talking about infant mortality, when I opened up my LA-1K to install the replacement power switch (shipped to me by Palstar) I couldn't believe seeing the overwhelming numbers of made-in-china (i.e. PRC) components inside my LA-1K.? So, the "MADE IN USA" label on the back of the LA-1K really doesn't mean much at all.

Again, buyers beware!!

73,
Ray
KJ5MI




Re: 120/240V switch?

 
Edited

I run my LA1K on a dedicated 240V circuit, and the voltage reading on the outlet is 242 Volts on Mains, and 239V when on backup generator.


Re: 120/240V switch?

 

Ron,

In saying that you "run the amp from a 240V dedicated circuit" I am sure you have verified its output with a voltmeter.

What's the VAC readout on your voltmeter for your 240V dedicated circuit?

73,
Ray
KJ5MI


Re: 120/240V switch?

Dave Bates
 

Folks, It pays to read the entire thread …

1) in sumary, some units have a switch on the left side of the unit. This must be switched accordingly to whatever voltage you intend on running. And you must use the appropriate cord to fit your wall socket/power receptacle. If you neglect to do this and power up with the switch in the wrong setting, YOU WILL BE SORRY.

2) Some units DO NOT have said switch ( like mine )
And all that is required is to change the power cords.? No taps to change on the PS.
?
Dave, KF?XQ?
Happy owner of an LA-K and HF-AUTO. “Twins”

On Fri, Mar 31, 2023 at 5:50 AM Olen Persons via <w4ezr=[email protected]> wrote:
Just Change to the 220 cord. ?

Olen Persons
704-201-9446


On Mar 20, 2023, at 5:02 PM, Steve Shep <shepsvettes@...> wrote:

?
The newer ones have a switch?



Sent from my Verizon, Samsung Galaxy smartphone


-------- Original message --------
From: Eric Clanton <drericclanton@...>
Date: 3/20/23 1:55 PM (GMT-08:00)
Subject: Re: [la1k] 120/240V switch?

I've used two different ones on both 120 and 240, neither of them have a switch.?

On Mon, Mar 20, 2023 at 3:42?PM Craig S <craig.savage@...> wrote:

Hi
I am about to switch over to using 240V instead of 120V, however Palstar support advised that I ensure I toggle some switch on the amp to set it to 240v. I can’t for the life of me find this switch or any mention of needing to do that in the manual - anyone able to help??

Thanks
-Craig
Wi0R



--
Eric D.Clanton DVM


256-435-8387
WN4WDE


"Life's tough......it's even tougher if you're stupid"?? -- John Wayne

--
Dave Bates


Re: 120/240V switch?

 

I received my amp from Palstar in Sept 2022 and it had a rather large warning flyer in the bag with the power cords (attached).? I didn't miss it and I run the amp from a 240V dedicated circuit.


Re: 120/240V switch?

 

开云体育

Just Change to the 220 cord. ?

Olen Persons
704-201-9446


On Mar 20, 2023, at 5:02 PM, Steve Shep <shepsvettes@...> wrote:

?
The newer ones have a switch?



Sent from my Verizon, Samsung Galaxy smartphone


-------- Original message --------
From: Eric Clanton <drericclanton@...>
Date: 3/20/23 1:55 PM (GMT-08:00)
Subject: Re: [la1k] 120/240V switch?

I've used two different ones on both 120 and 240, neither of them have a switch.?

On Mon, Mar 20, 2023 at 3:42?PM Craig S <craig.savage@...> wrote:

Hi
I am about to switch over to using 240V instead of 120V, however Palstar support advised that I ensure I toggle some switch on the amp to set it to 240v. I can’t for the life of me find this switch or any mention of needing to do that in the manual - anyone able to help??

Thanks
-Craig
Wi0R



--
Eric D.Clanton DVM
1519 Pelham Rd
Jacksonville, AL 36265
256-435-8387
WN4WDE


"Life's tough......it's even tougher if you're stupid"?? -- John Wayne


Re: 120/240V switch?

 

Steve,

When was your LA-1K delivered to you brand new?

My LA-1K, purchased brand new directly from Palstar, was delivered to me on January 21, 2023.? My current home station configuration with the LA-1K (Serial Number: 38935) can be seen on my QRZ page at

Started out powering the LA-1K using my home wall outlet (just under 125VAC according to my Craftsman DVM) at proper power supply switch position same day I took possession of the thing.? After seeing some error messages (power supply related) on the LA-1K display, I consulted with Mark Ward (Palstar tech support) about them first thing the following week.? Mr. Ward advised me to ignore the power supply information in whole, as printed on Page 15 of the technical manual (hard copy) that came with my LA-1K shipment, since Palstar failed to update their LA-1K technical manual.

So, having "read the manual front to back several times" as you did.. could have complicated your power supply issues since the manual in question is outdated, Steve!

Bottom line:? Buyers beware!!!

73,
Ray
KJ5MI


Re: 120/240V switch?

 

I think I purchased my LA-1K in December.? It has the red switch on the on the left side, inside the hole in the case.? I toggled my switch numerous times to get the feel of it.? I have left it on 120 volt because that is where I intend to use it.


Re: I need help making the cable that connects the Yaesu FT DX-10 to the Palstar LA-1K Amplifier

 
Edited

Hi Jim!

Kidding about what?? If you are referring to the Palstar LA-1K not working...nope, not kidding.? After performing multiple tests with Palstar using over the phone testing, they now tell me the amplifier is not working.

I just got back from Fed Ex.? We shiped it back to Palstar.

If you are asking about kidding in regards to the various cable options, I just received another cable...this one is the 8 pin/RCA version that connects to the 8-pin tuner jack on the back of the FT DX-10, then to the RCA on the Palstar.

The third option, the 10 pin din plug from the FT DX-10 linear jack to the RCA jack on the LA-1K is sold on Ebay, but the vendor just went on vacation and has indicated he will not sell or ship until he returns from his vacation.

What an incredible and strange adventure this has been.

Finally seeing light at the end of then long, long tunnel!

How are you and what type of linear amplifier are you using?


Re: 120/240V switch?

 

开云体育

I have the auto switch power supply , but I would guess Palstar should probably placard the power cord and the side of the amplifier to prevent this kind of failure.?



Barry??


On Mar 28, 2023, at 11:06 AM, Steve <steveki0sx@...> wrote:

?I can assure you it is best to look for the switch!? I got one of the first to roll out with the new power supply. I had read the manual front to back several times while I awaited delivery.? When it camw in I tossed all the paperwork aside and proceeded to set it up.? The day I got it I did not have my 240V run in.? Powered it up on 120v and all was well. The next day I completed my 240v install, switched cords and powered up.? There was a loud boom and smoke.Needless to say my amp was on its way back for "not covered" repair.


Re: Band data config for an Anan 7000 DLE MkII?

 

I replied, no I didn't. The RF detection worked well enough I left it alone. I run non-resonant antennas so I have to tune anyway, so I put the amp in standby, tune with 10-15W and then put the amp into oper and go. I also have an RFKit that uses TCI for CAT but it doesn't put the amp in standby to tune so the procedure I use is identical even with band switching run by CAT. I put the amp in standby, send a tune signal and then put it in operate.

If you want to put the amp into standby when you hit tune, you will need an external utility, something like Node Red that will first send a command to put the amp in standby and then activate the rig to send a tun. You would use the external utility to tun, not the rig directly as it will have to put the amp in standby via a command first before the rig is triggered.


On Tue, Mar 28, 2023 at 11:06?AM Sonny Jobe <hgjobe@...> wrote:
Hey Chris,
I sent you an email using your QRZ address on this. I am running the same setup and wanted to know if you got this working so that the LA-1K went to stand-by when you tuned using Thetis.

Sonny WC8L


Re: Band data config for an Anan 7000 DLE MkII?

 

Hey Chris,
I sent you an email using your QRZ address on this. I am running the same setup and wanted to know if you got this working so that the LA-1K went to stand-by when you tuned using Thetis.

Sonny WC8L


Re: I need help making the cable that connects the Yaesu FT DX-10 to the Palstar LA-1K Amplifier

Jim KE4WY
 

Please tell me you are kidding?

Jim KE4WY

On Tue, Mar 21, 2023 at 7:38?PM <heraldranch777@...> wrote:

David,

I do not even have a PTT cable installed.? Are you saying the Yaesu FT DX-10 to the Palstar LA-1K Amplifier requires an additional PTT Cable?

Or, are you saying the Yaesu FT DX-10 to the Palstar LA-1K Amplifier set up would work with ONLY a PTT cable?

Please clarify.

Thank you!

Dirk


Re: 120/240V switch?

 

I can assure you it is best to look for the switch!? I got one of the first to roll out with the new power supply. I had read the manual front to back several times while I awaited delivery.? When it camw in I tossed all the paperwork aside and proceeded to set it up.? The day I got it I did not have my 240V run in.? Powered it up on 120v and all was well. The next day I completed my 240v install, switched cords and powered up.? There was a loud boom and smoke.Needless to say my amp was on its way back for "not covered" repair.


Re: I need help making the cable that connects the Yaesu FT DX-10 to the Palstar LA-1K Amplifier

 

I think we have isolated the problem.? Mark at Palstar just helped me run a number of tests on the LA-1K and he is convinced the linear is not working correctly.? We will ship it back to Palstar asap.


Re: I need help making the cable that connects the Yaesu FT DX-10 to the Palstar LA-1K Amplifier

 

Yes I did.


Re: I need help making the cable that connects the Yaesu FT DX-10 to the Palstar LA-1K Amplifier

 

Did you go into the LA-1K menu and set it to use the data cable? There is a setting for that so if you removed the rca cable and didn't switch it to use the data cable it will not key the amp.


Re: I need help making the cable that connects the Yaesu FT DX-10 to the Palstar LA-1K Amplifier

 

Quick update:

I received the cable from Paul at Palstar and tested the amplifier.? It still does not work.? So now I am thinking it is either the the LA-1K, my new Yaesu FT DX-10, the Palstar HF Auto, antenna, etc.

Special note: The Palstar HF Auto works perfect with my Yaesu FT DX-10 and tri-band dipole as well as with my other antenna, the Antron A-99.? My center-fed tri-band antenna is resonant on 20, 40 and 75.? The Antron A-99 is nearly flat for a large band width in 28 MHz.

Palstar informed me I can send the new LA-1K back if the cable did not work.? |

Before sending it back, is there anything I could be missing here?

For example: is it possible it is the Yaesu FT-DX-10 is not working properly with the LA-1K due to some type of missed settings?

What other tests could I do before shipping the LA-1K back to Palstar?

Thanks,


AJ6XW


Re: I need help making the cable that connects the Yaesu FT DX-10 to the Palstar LA-1K Amplifier

 

Yep, you’re correct there is no TX IN for the FTDX10.?

It’s actually TX Out (Pin 2 - Yellow) to Amp key In (Pin 7 - Yellow) on the LA-1K.?

In other words: FTDX10 output to LA-1K input.


Only 6 pins are used:

Blue wire from cable to Pin 1 of socket (Band data B)

Red wire from cable to Pin 2 of socket (Band data A)

Green wire from cable to Pin 6 of socket (Ground)

Yellow wire from cable to Pin 7 of socket (Amp key input)

Violet wire from cable to Pin 8 of socket (Band data D)

Blue wire from cable to Pin 9 of socket (Band data C)


Cable used: Yaesu SCU-28

Connector used: DB9 RS232 at: ?


I did continuity tests on the connections and used solder not the screw-downs to connect the wires.

This set up has worked perfectly with no problems at all.


Hope this helps


On Wed, Mar 22, 2023 at 9:27?PM David Campeau <davidc502@...> wrote:
That's an awesome resource! I knew there was someone like yourself that
had already done the work, so thanks for sharing.

Best Regards,

David Campeau ki4dra

On 3/22/2023 5:52 PM, Bill K3HZP wrote:
> David,
> You are on the right track.? The info on my website might help clarify the differences of the two modes of operation.
>
>? ? ? ? ? ?73
> .... Bill K3HZP
>
>
>
>
>
>