¿ªÔÆÌåÓý

Date   
Locked Sticky ADMIN: Use of the groups "Files" area #admin
This is a place for temp files, other than administrative files. Either they are to be added to the next release, added to the Documents or will have a short life span. Groups.io has free subscription storage limit of 1 GB! The following are counted towards the storage limits for the group: - Files - Photos - Images in databases - Images in wiki pages - Message attachments 1. Please put files into the correct folders. - If there is not an appropriate folder, feel free to create one. 2. If you are working on a problem and want to load info for others to look at, create a folder within the 'Problems Being Worked On' folder using the Msg number or you name as the folder name. When the problem is resolved please delete the folder. 3. All files and photos are subject to removal at the moderators discretion. Your Moderators -- Peter Ulvestad JMRI Users Group Moderator - http://www.jmri.org ( http://www.jmri.org ) Tam Valley Group Moderator - https://tamvalleydepot.com/ ( http://tamvalleydepot.com/ ) Sprog-DCC Group Moderator - http://www.sprog-dcc.co.uk/ ( http://www.sprog-dcc.co.uk/ ) Edmonton Model Railroad Association - http://www.emra.club/
Started by Peter Ulvestad @
Locked Sticky ADMIN: >>HOW TO ASK YOUR QUESTION<< - A general reminder for everyone #admin
====================== HOW to ask your question ====================== One of the most common questions about JMRI is "How do I get it to work?". This isn't really a problem with JMRI itself in most cases, but there are HUGE numbers of possible configurations for DCC systems, and Windows, Linux, and Mac computers out there. Just asking "How do I get it to work" is NOT going to get you any useful help. When asking ANY question, you should >>>utilize a meaningful subject line<<< that indicates the problem and include the following information in the body of the message: + If JMRI has started copy and paste the System Console into the body. (its under help on the start screen) + Has JMRI worked before on this computer? + JMRI version + Previous version if you just upgraded + Java version + Previous version if you just upgraded + Computer make and model + if you have just upgraded, from which version + Any other DCC devices in use + Specific details of your difficulty including error messages if any, or what you would like to do with JMRI. Decoder Programming, Signals, Automation, etc. Depending on the nature of the problem, you may need to supply even more information, but this is the absolute required for anyone to give you accurate answers. Signing you post helps keep the group friendly and personable! Your moderators and trouble shooters.
Started by Peter Ulvestad @
Locked Sticky Please use "meaningful subject lines" when starting topics #admin
Please use "meaningful subject lines" when starting topics. We are getting lots of subject lines that don't give much if any idea of what the topic is about. By providing a meaningful subject line you may get the attention of someone that can provide you assistance with your issue. It also give others the chance to skip the topic if it is not of interest to them. -- Peter Ulvestad JMRI Users Group Moderator - https://www.jmri.org ( http://www.jmri.org ) Tam Valley Group Moderator - https://tamvalleydepot.com/ ( http://tamvalleydepot.com/ ) Sprog-DCC Group Moderator - http://www.sprog-dcc.co.uk/ ( http://www.sprog-dcc.co.uk/ ) Edmonton Model Railroad Association - http://www.emra.club/
Started by Peter Ulvestad @
Locked Sticky ADMIN: PERMITTED TOPICS - A general reminder for everyone #admin
We would like to point out that this list is for discussions related to JMRI, and is intended to be a place that people, particularly beginners, can turn to for help with their JMRI problems from more experienced JMRI users. General DCC and model railroading topics should be taken to a more appropriate forum and NOT be posted here. SPAM of any kind, politics, legal issues, and other off-topic matters should NOT be posted to the list and will be subject to deletion by the moderators, as will any responses to such off-topic matters. New members still on moderated status will find that off-topic posts will not be approved for posting, and old members making such posts may find themselves back on moderated status. BUY / SELL and ADVERTISING is NOT PERMITTED Let's keep things simple for all of us, and keep the discussion here on-topic. Your moderators
Started by Group Moderator @
Calculating speed changes in automation 5
? Dear Steve or anyone else who can help You said ¡° in the selection box at the bottom, enter jmri.jmrit.dispatcher Select TRACE from the level selector, Click Set new logging level. View the output in the main JMRI console.¡± You said this will tell me how the speed changes are being calculated. Which i did. But if you check the system console you will see when i did as you said but after that message there is nothing coming from the dispatcher telling me about speed changes. Exactly where is the info? If you check the monitor data , which apparently has lost the data at the startup and the creation of the trains, the train t4912 in slot 13 which had its max speed set to 100 at creation is being assigned a speed of 61 on restarts and t53 in slot 8 which had its max speed on creation set to 40 is running at speed 51 on restarts. I assume its suppose to be assigned a normal speed on startup with warrants normal set at 100% throttle and warrants slow at 50% throttle. So why is the speed of t53 ¡®51¡¯ greater than normal on restart (40 max on creation) while the speed of t4912 about correct if its set to slow. I have no idea what¡¯s happening and the system console has no information which you implied it would Please explain whats going on The data below is not for analysis but to be used to explain what i am doing wrong Also please explain how to read the few warnings that is telling me about the blocks and sensors which constantly repeat. Tony Begin forwarded message: From: TONY BBC <TONY_BBC@...> Date: April 24, 2025 at 3:37:00 PM EDT To: ANTHONY DALILEO <bklyns_baseball_club@...> Subject: info ? Loconet monitor 15:30:04.342: [D0 00 2C 26 30 15] Transponder address 4912 absent at LR45 () (BDL16x Board ID 3 RX4 zone G or BXP88 Board ID 6 section 5 or the BXPA1 Board ID 45 section). 15:30:06.893: [B2 14 60 39] Sensor LS42 (SENSOR B42) is Low 15:30:07.274: [B2 16 40 1B] Sensor LS45 (SENSOR B45) is Low 15:30:07.594: [B2 15 50 08] Sensor LS43 (SENSOR B43) is High 15:30:07.651: [A0 0D 00 52] Set speed of loco in slot 13 to 0. 15:30:07.651: [A0 0D 00 52] Set speed of loco in slot 13 to 0. 15:30:07.651: [D0 20 2A 26 30 33] Transponder address 4912 present at LR43 () (BDL16x Board ID 3 RX4 zone F or BXP88 Board ID 6 section 3 or the BXPA1 Board ID 43 section). 15:30:08.205: [A0 0D 40 12] Set speed of loco in slot 13 to 64. 15:30:08.392: [B2 16 70 2B] Sensor LS46 (SENSOR B46) is High 15:30:08.455: [A0 08 00 57] Set speed of loco in slot 8 to 0. 15:30:08.455: [A0 08 00 57] Set speed of loco in slot 8 to 0. 15:30:08.596: [A0 08 33 64] Set speed of loco in slot 8 to 51. 15:30:08.924: [BB 7B 00 3F] Request Fast Clock information. 15:30:08.924: [E7 0E 7B 01 0F 09 60 07 77 18 00 00 00 62] Response Fast Clock is Synchronized, Running, rate is 1:1. Day 24, 15:29. Last set by ID 0x00 0x00 (0). Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available. 15:30:09.518: [B2 05 50 18] Sensor LS11 (B11 SENSOR) is High 15:30:09.815: [D0 00 2B 26 30 12] Transponder address 4912 absent at LR44 () (BXP88 Board ID 6 section 4 or the BXPA1 Board ID 44 section). 15:30:11.019: [B2 05 40 08] Sensor LS11 (B11 SENSOR) is Low 15:30:11.112: [B2 14 40 19] Sensor LS41 (SENSOR B41) is Low 15:30:13.840: [B2 15 60 38] Sensor LS44 (SENSOR B44) is Low 15:30:14.105: [B2 16 50 0B] Sensor LS45 (SENSOR B45) is High 15:30:14.166: [A0 08 00 57] Set speed of loco in slot 8 to 0. 15:30:14.166: [A0 08 00 57] Set speed of loco in slot 8 to 0. 15:30:15.145: [A0 08 33 64] Set speed of loco in slot 8 to 51. 15:30:16.302: [B2 14 70 29] Sensor LS42 (SENSOR B42) is High 15:30:16.667: [D0 20 29 26 30 30] Transponder address 4912 present at LR42 () (BXP88 Board ID 6 section 2 or the BXPA1 Board ID 42 section). 15:30:16.979: [BB 07 00 43] Request data/status for slot 7. 15:30:16.995: [E7 0E 07 13 6D 01 00 07 00 30 00 71 02 2A] Report of slot 7 information: Loco 6253 is Not Consisted, Common, operating in 128 SS mode, and is moving Forward at speed 1, F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off Master supports LocoNet 1.1; Track S
Started by AD @ · Most recent @
JMRI PANEL PRO STARTUP FAILURE
using jmri 5.10 i open panel pro which ,on startup, opens system console, loconet monitor, slot monitor , 4 speedoipmeters,clock,dispatcher, then opens default throttles-10 throttles, 8 set with decoder numbers and the last 2 without any engine selected. everything opens properly until the last throttle when i get message window saying ¡°failed to create throttle¡± . The panel pro window opens last but is empty of information as the error window. i can control the cursor but cannot close any windows. Except for cursor movement the computer does not respond to any click. i force shut off the computer and restart when everything loads fine. this happens every time the computer is turned on for the first time. its a dell laptop running windows 11. Dell just reinstalled the bios and a bunch of other things. this happened both before and after the bios updates. any idea what could let the software not create a new throttle and then freeze. tony
Started by AD @
Traversing Blocks too quick or too slow - Dispatcher vs Warrants 2
I know with Warrants, it can take action if an autotrain is not traversing blocks at the appropriate duration (described in the doco as...) Warrant dynamic speed profiling, measurements are made over straight level track, but also upgrade, down grade, curved gently or severely, running light or pulling 30+ cars. The track speeds are not going to be all the same for a given throttle setting When merging, new values are averaged with the old, with the intention of a composite speed profile that reflects average use. Does Dispatcher have such functionality or an equivalent? -- H.O. Australia (Layout in Progress) Digikeijs DR5000 LocoNet JMRI v5.10 DecoderPro/Warrants/CPE/SML/LogixNG Java: OpenLogic jre-17.0.12.7 Windows 10
Started by Nags @ · Most recent @
Full write of stored CVs to restore corrupted decoder 4
I returned to my layout after a lengthy vacation and attempted to Start running a pair of locomotives that I had successfully speed managed to speed match, and found that neither loco would move. The track and wheels are not dirty. The start-up sounds work, and lighting, horn, and bell commands all work. I am wondering if I can over write motor and speed settings stored in decoder pro. If so, what is the process? -- Neil of Bird Town Minnesota - Coffeeville Line
Started by Neil Kryder @ · Most recent @
Disconnect between signal aspect showing on JMRI and ACTUAL signal aspect on layout 6 #nce
Hi JMRI user group, This little black duck in St. Clair, Sydney, finally got some signalling up & running, sort of... Is there any known issue[s] with JMRI and NCE that would cause JMRI to correctly show the aspect of a given [3 aspect] signal, BUT have the equivalent physical signal on my layout inconsistently update [or not] its aspect? Note I said 'inconsistently', because some of the time a given signal will update correctly, another time not. [And it is not always the same signal that fails to update; it all appears rather random.] SOME DETAILS Simple loop running at present under test. Approximately 15 signals in the large-ish loop. Currently running LOGIX programmed to have one signal RED, one signal AMBER, the remainder GREEN. Logix operates correctly 'on screen' or 'virtually'. I have tried various ways of programming the signal sequence, but always run into the same problem of inconsistent updating of aspects. HARDWARE - all NCE NCE PowerPro, NCE BD20 sensors [all track 'sensed'], NCE AIUs, their channels switched via the sensors. Each signal is connected to an NCE 'Light-it' stationary decoder acting as its driver. ADDITIONAL OBSERVATIONS Signals, when manually operated from the PC [JMRI signal table] update as directed 'on screen' & 'on layout', no failures. AIU on board channel indicators [LEDs] operate correctly and cause JMRI sensor table to shown sensors as 'active' or 'inactive' as expected. At one point I thought there may be data loss occurring through the 'bus' between the NCE system and the signal drivers, but this doesn't appear to be the case. I say this because I have one of the signals connected to the 'track bus' within 6 inches of the NCE box - and it still fails to update at times. I can't take the project any further until reliability of correct aspect be attained. I can supply more detailed info to anyone who thinks they can help. Regards, Nimble
Started by Nimble Knumblebum @ · Most recent @
LogixNG class based show/hide and enable/disable for Senor icons requires web page refresh 3 #layouteditor #logixng
I'm using Class based control of layout editor panel icons. In particular show/hide but have also tried enable/disable. e.g. 1: LogixNG: DisableYardRoutes 2: ConditionalNG: EF-L2 ::: Startup 3: ! A 4: Many 5: ! A1 6: If Then Else. Execute on change 7: ? If 8: Sensor TD-EF-L2-Stop is Inactive 9: ! Then 10: Set icon/label by class "DisableableEFL2Sensor" on panel "Exeter Yard Control" to "Hide" 11: ! Else 12: Set icon/label by class "DisableableEFL2Sensor" on panel "Exeter Yard Control" to "Show" 13: ! A2 Whilst the function seem to operate successfully my problem is with display refresh. On the 'native' JMRI panel refresh is delayed until the mouse is moved into panel window. On web browser the situation is worse in that the panel needs a refresh (F5) before the updates take effect. I was hoping to use the method for dynamic control of sensor icon visibility (or to disable sensor), but the web issue especially make me wonder if I'll have to think of another method. I was hoping to use the method to display available options for controlling train movements into and out of fiddle yards. I'm using jmri 5.11.5 with java 21.0.6 under Ubuntu 24.04.2 LTS Thanks Andy
Started by Andy Brown @ · Most recent @
HELP! Power unknown issue with JMRI - Trying to use wifi throttle with JMRI and NCE power cab 10
I was able to get the interface to be seen by the computer when running it through the cobalt power box. I could see it through the DecoderPro but when trying to use PanelPro for the wireless throttle i ran into an issue. The button to turn the server on was yellow and i was unable to turn it on or off. It gave me a message saying that power was unknown and to click to turn it off, but that didn't work. I then tried to use the interface normally through just the NCE powerCab and to my surprise the same issue was happening. DecoderPro could see it but i noticed that the power button located on the top right was also yellow. My goal is to get WiFi throttle to work but i was unable to even turn on the server through PanelPro and I'm unsure of what the issue is Essentially I've hit a wall where I can't seem to power on or see the power status of my NCE when working with the application. I need to find out how to be able to turn this on to see if i can get the WiFi to work with just the NCE System itself.
Started by UP-Railroad 844 @ · Most recent @
Multiple RFID tags in one block 7
I must admit I am having a hard time grasping all the options available for RFID, reporters and block tracking. Is there a way to handle more than one RFID tag in a block? If I had RFID tags on all units, and RFID readers on all block borders, I would have a train of tags moving around. A double reader could indicate the direction of travel. On my 1:8 scale garden railroad this is quite feasible. A Cbus node with an arduino nano and 2 cheap readers on every block border could do the job. A tag should be in only 1 block - when a it enters a block it should be removed from any previous block. Block occupancy is based on at least 1 tag in the block, to be shown on the panel. But how can I do this in JMRI? Regards, Torgrim
Started by Torgrim Gjelsvik @ · Most recent @
Reading CVs 15 #zimo #mxulf
Hello, and thank you for accepting me into the group. I live in Stockholm, Sweden, and play around with a variety of digital equipment from ESU, M?rklin, and Zimo. I came across JMRI app because I am looking for the decoder reader of the settings of PIKO and D&H. Equipment seems to work, as it is reading out the CV, but the problem is that it comes in the random order, for example it returns different numbers even with the same CV input. JMRI version 5.11.5+R6be2a2b4e8 Java version 17.0.12 MXULF 00.84.112 / COM port 3 Is this common issue in this version, that MXULF is not supported, or is this the case of something else? Best regards Jonas
Started by jonas_sth @ · Most recent @
Ghost Block Issue? 3 #signalmasts #autotrain #blocks
I have an issue I can't track down and think it might have something to do with ghost block. It's repeatable. Every car in both trains is detectable. (I use BDL716 and tests show it very sensitive and reliable.) Amtrak (top left in screenshot), FEC (bottom right in screenshot) Amtrak has higher priority Waits about half a block west of the turnout for it to close before proceeding thru eastbound FEC stops at beginning of block Turnout closes and Amtrak proceeds eastbound Dispatcher throws turnout as soon as preceding block clears and before last passenger car clears causing short Here's a screenshot and some logs: Dispatcher allocated the turnout and threw it while a car was on the turnout. It shouldn't matter for this but my blocks are all longer than the train and have accurate dimensions as well as the train has accurate dimensions. I also check full train in autotrain. I don't believe an intermittent bounce would matter since the BDL716 has debounce and I've never seen the test LEDs on BDL flicker. Here's a log snippet of the action. DEBUG - FEC: handleBlockStateChange to OCCUPIED section B10:B10 (IY:AUTO:0030), block B10 (IB:AUTO:0010), length 1117 [Allocated Section Block Change on B10] DEBUG - FEC: new current signalmast B10-B16 (IF$vsm:basic:one-low($0076))(Approach) for section B10:B10 (IY:AUTO:0030) [Allocated Section Block Change on B10] DEBUG - FEC: B10-B16 (IF$vsm:basic:one-low($0076))(Approach) Medium(50), Dest: T6TD-B2 (IF$vsm:basic:one-low($0037)), path max: 100 [Allocated Section Block Change on B10] DEBUG - FEC: Signal B10-B16 (IF$vsm:basic:one-low($0076)) setting speed to 50.0 for next [Allocated Section Block Change on B10] DEBUG - FEC: setTargetSpeedValue: Speed[50.0] [Allocated Section Block Change on B10] DEBUG - setTargetSpeed: Set Speed[0.5] adjusted to TargetSpeed[0.5] [Allocated Section Block Change on B10] DEBUG - RampToTarget[0.5]current[0.5] [Allocated Section Block Change on B10] DEBUG - Remove TransitSection[IY:AUTO:0007( B11:B11 )] [AWT-EventQueue-0] DEBUG - FEC: releasing section [B11:B11 (IY:AUTO:0007)] [Auto Allocator ] DEBUG - FEC: handleBlockStateChange to UNOCCUPIED - Section B11:B11 (IY:AUTO:0007), Block B11 (IB:AUTO:0011), speed 0.5 [Allocated Section Block Change on B11] DEBUG - Remove TransitSection[IY:AUTO:0008( T4:T4 )] [AWT-EventQueue-0] DEBUG - FEC: handleBlockStateChange to UNOCCUPIED - Section T4:T4 (IY:AUTO:0008), Block VBT4 (IB:AUTO:0016), speed 0.5 [Allocated Section Block Change on VBT4] DEBUG - FEC: releasing section [T4:T4 (IY:AUTO:0008)] [Auto Allocator ] DEBUG - Adding TransitSection[IY:AUTO:0034( B16:B16 )] [AWT-EventQueue-0] DEBUG - FEC / B10Loop:Next Section Expected[true] [AWT-EventQueue-0] DEBUG - FEC: handleBlockStateChange to OCCUPIED section B16:B16 (IY:AUTO:0034), block B16 (IB:AUTO:0026), length 914 [Allocated Section Block Change on B16] DEBUG - FEC: new current signalmast T6TD-B2 (IF$vsm:basic:one-low($0037))(Stop) for section B16:B16 (IY:AUTO:0034) [Allocated Section Block Change on B16] DEBUG - FEC: StopInCurrentSection called for B16:B16 (IY:AUTO:0034) task[0] targetspeed[0.5] [Allocated Section Block Change on B16] DEBUG - FEC: train will fit in [B16:B16 (IY:AUTO:0034)] (914>=609), stop when prev block clears. [Allocated Section Block Change on B16] DEBUG - setTargetSpeed: Set Speed[0.0] adjusted to TargetSpeed[0.0] [Allocated Section Block Change on B16] DEBUG - RampToTarget[0.0]current[0.5] [Allocated Section Block Change on B16] DEBUG - FEC / B10Loop:Set Stop [Allocated Section Block Change on B16] DEBUG - Adding TransitSection[IY:AUTO:0004( B2a:B2a )] [AWT-EventQueue-0] DEBUG - Amtrak / B3Loop:Next Section Expected[true] [AWT-EventQueue-0] ERROR - [Amtrak / B3Loop]direction[false] Section[B15Crossing (IY:AUTO:0006)]Error in turnout check/set request - initial Block[B1] and Section[B1 (IB:AUTO:0001)] mismatch [Auto Allocator ] DEBUG - Amtrak: handleBlockStateChange to OCCUPIED section B2a:B2a (IY:AUTO:0004), block B2a (IB:AUTO:0028), length 1117 [Allocated Section Block Change on B2a] DEBUG - Amtrak: Allocated section [B15Crossing (IY:AUTO:0006)]
Started by stevemac @ · Most recent @
automation run 2
Begin forwarded message: From: TONY BBC <TONY_BBC@...> Date: April 22, 2025 at 3:07:32 PM EDT To: ANTHONY DALILEO <bklyns_baseball_club@...> Subject: automation run ? if there is someone who can read system console and loconet monitor data and has some time to take a look at a few things and can tell me how to find them. i run t103 -slot 5 in automation and it goes from b39-b33-b34-b35-b36 where it stops. this is proper as b35 & b36 turns red on the layout panel as thats where the train is. i then run t150-slot6 in automation and it properly stops in b34. 1.i entered jmri.jmri.dispatcher and change to trace and clicked set button at bottom of window you told me to go to. i dont see anything in system console showing me the speed calulations as you indicated i would. can you show me where they are and what they say? 2. after t103 enters b36 it turns red with the train stopped. but a few seconds later it turns yellow which should have caused the train to startup again but it doesnt. Did the program tell it to run at spped 0 or another speed and the engine just physicall didnt respond which happens with this european engine at low speeds? 3. After t150 cleared b38 then t103 starts running. what did the program do to now get it moving? Is the trace working If so how do i find and understand it Is there anything else you can tell me about all the warnings. Ignore switch warnings. The switches on the panel are not used and are for information only to show all the other parts of the layout. This panel only uses the 5 loops-no interconnection. tony system console 14:39:10,909 apps.util.Log4JUtil INFO - * JMRI log ** [main] 14:39:10,925 apps.util.Log4JUtil INFO - This log is stored in file: C:\Users\TONY_\JMRI\log\session.log [main] 14:39:10,925 apps.util.Log4JUtil INFO - This log is appended to file: C:\Users\TONY_\JMRI\log\messages.log [main] 14:39:10,987 apps.Apps INFO - PanelPro version 5.10+Rca461bd266 starts under Java 17.0.11 on Windows 11 amd64 v10.0 at Tue Apr 22 14:39:10 EDT 2025 [main] 14:39:11,208 t.permission.DefaultPermissionManager INFO - Permission file: C:\Users\TONY_\JMRI\.permissions.xml [main] 14:39:11,224 t.permission.DefaultPermissionManager INFO - Permission system is enabled: no [main] 14:39:14,124 apps.Apps INFO - Starting with profile JMRI_5_10_2025_N_SCALE_MAIN_8X8_LAYOUT_NOSW_SML_wLEN.3f47d6ef [main] 14:39:14,314 jmri.util.node.NodeIdentity INFO - Using 95f457ac-783f-4dfc-ac13-ccc5031b3a30 as the JMRI storage identity for profile id 3f47d6ef [AWT-EventQueue-0] 14:39:14,501 xml.AbstractSerialConnectionConfigXml INFO - Starting to connect for "LocoNet" [main] 14:39:14,537 onet.locobufferng.LocoBufferNGAdapter INFO - Connecting LocoBuffer-NG via COM3 CDC ACM SERIAL DEVICE [main] 14:39:14,552 .loconet.locobuffer.LocoBufferAdapter INFO - LocoNet: Port USB Serial Device (COM3) opened at 57600 baud, sees DTR: true RTS: true DSR: false CTS: false DCD: false flow: RTSCTS [main] 14:39:14,651 jmri.jmrix.loconet.LnPacketizer INFO - lnPacketizer Started [main] 14:39:15,064 jmri.jmrit.roster.Roster INFO - Reading roster file with rootFromName(C:\Users\TONY_\JMRI\JMRI_5_10_2025_N_SCALE_MAIN_8X8_LAYOUT_NOSW_SML_wLEN.jmri\roster.xml) [main] 14:39:18,018 jmri.util.startup.PerformFileModel INFO - Loading file C:\Users\TONY_\JMRI\N_SCALE_2025_JMRI_5_10_LAYOUT_PANELS_REF\N_SCALE_2025_8X8_LAYOUT_PANEL_MAIN & CTC_NOSW_SML_LTS_REF.xml [main] 14:39:27,036 t.display.layoutEditor.BlockValueFile INFO - 8 of 8 block values restored. Rule=RESTOREONLYIFALLOCCUPIED, Power=ON [Thread-6] 14:39:27,352 jmri.util.FileUtilSupport INFO - File path program: is C:\Program Files (x86)\JMRI\ [main] 14:39:27,353 jmri.util.FileUtilSupport INFO - File path preference: is C:\Users\TONY_\JMRI\JMRI_5_10_2025_N_SCALE_MAIN_8X8_LAYOUT_NOSW_SML_wLEN.jmri\ [main] 14:39:27,353 jmri.util.FileUtilSupport INFO - File path profile: is C:\Users\TONY_\JMRI\JMRI_5_10_2025_N_SCALE_MAIN_8X8_LAYOUT_NOSW_SML_wLEN.jmri\ [main] 14:39:27,353 jmri.util.FileUtilSupport INFO - File path settings: is C:\Users\TONY_\JMRI\ [main] 14:39:27,354 jmri.util.FileUtilSuppo
Started by AD @ · Most recent @
Nce power cab issue 10
I have two Nce power cabs. Both with upgraded chips. Both work perfect on my programming track as well as on the main . The challenge I am having is that only one of the Pcabs works with Jmri as in being able to program my decoders. The other one just will not . The message i get on the system console as per attached screenshot. As far as I know they both have the equivalent settings.
Started by Peter @ · Most recent @
Invisible pop ups 3
I have a regular problem with pop-ups from JMRI not being visible, which then renders JMRI unusable until restarted. This is on a raspberry pi originally built using the image provided. Access is via VNC. I have version: PanelPro version 5.10+Rca461bd266 starts under Java 17.0.14 on Linux aarch64 v6.6.74+rpt-rpi-2712 at Mon Apr 21 08:52:21 BST 2025 [main] The display is wayland, and the hardware is an 8g Rasberry PI 5 (but I also saw this on my old rasberry pi 4) The behaviour appears to be random, I just had it when trying to write this by going to "Help -> About PanelPro" but on restart it's fine. I see it most when editing LogixNG when it's popping up a warning that I need to complete editing a logixng before exiting that edit. Any ideas? Thank you Chris
Started by Chris Gerhard @ · Most recent @
WiFi Throttle Handset 8
I¡¯m looking for a handheld physical throttle for use on a WiThrottle/JMRI/NCE system. I¡¯m pretty sure I saw information on here about a sleek device with buttons down the sides and a narrow screen down the middle showing the functions allocated, but I can¡¯t find it now. I¡¯d welcome any or all suggestions. I¡¯m experimenting with an old iPhone at the moment, but I¡¯m not keen on touch screens for this role. thanks
Started by Matthew Reed @ · Most recent @
Backups 5
in previous versions of jmri i got hundreds of backups of panels automatically without me doing a backup. using jmri 5.10 i open a profile which opens a layout panel. The panel had a table of switches in which i mistakenly erased the switches and saved the tables. i want to remove the latest panel and restore the panel with the switches table in it. i cannot find where the backup was stored. How do i find the panel with the table that existed before the erasure? I checked very directory and suspect this version of jmri does not automatically back up. Tony
Started by AD @ · Most recent @
SPEED used by train in automation 18
can anyone tell me how the speed of a train traveling in automation is determined as it entered each section when using sml virtual signals on a layout panel. there is the speed set in block tables, there is the speed definitions and their speeds and there is the max speed set when creating a train. what is their relationship to each other. in preference /warrents page what is %script mean, what is %throttle mean? tony
Started by AD @ · Most recent @
Current Image
Image Name
Sat 8:39am