Keyboard Shortcuts
Likes
Search
Disconnect between signal aspect showing on JMRI and ACTUAL signal aspect on layout
#nce
Hi JMRI user group, This little black duck in St. Clair, Sydney, finally got some signalling up & running, sort of... Is there any known issue[s] with JMRI and NCE that would cause JMRI to correctly show? the aspect? of a given [3 aspect] signal, BUT have the equivalent physical signal on my layout inconsistently update [or not] its aspect?? Note I said 'inconsistently', because some of the time a given signal will update correctly, another time not. [And it is not always the same signal that fails to update; it all appears rather random.] ? SOME DETAILS Simple loop running at present under test. Approximately 15 signals in the? large-ish loop. Currently running LOGIX programmed to have one signal RED, one signal AMBER, the remainder GREEN. Logix operates correctly 'on screen' or 'virtually'. I have tried various ways of programming the signal sequence, but always run into the same problem of inconsistent updating of aspects. ? HARDWARE - all NCE NCE PowerPro, NCE BD20 sensors [all track 'sensed'], NCE AIUs, their channels switched via the sensors. Each signal is connected to an NCE 'Light-it' stationary decoder acting as its driver. ? ADDITIONAL OBSERVATIONS Signals, when manually operated from the PC [JMRI signal table] update as directed 'on screen' & 'on layout', no failures. AIU on board channel indicators [LEDs] operate correctly and cause JMRI sensor table to shown sensors as 'active' or 'inactive' as expected. At one point I thought there may be data loss occurring through the 'bus' between the NCE system and the signal drivers, but this doesn't appear to be the case. I say this because I have one of the signals connected to the 'track bus' within 6 inches of the NCE box - and it still fails to update at times. I can't take the project any further until reliability of correct aspect be attained. ? I can supply more detailed info to anyone who thinks they can help. Regards, Nimble |
¿ªÔÆÌåÓýNimble, ? Only think I¡¯ve heard that might fit this is that if the commands to the Light-It come too fast, it will see the first command and miss the second command. I¡¯ve not seen it myself but have heard it happen to so. There were comments, either here or on the NCE list, and I recall some solution was found. Around six months ago, I think. ? -Ken Cameron, Member JMRI Dev Team
? ? |