Re: Adding new "info" field to the Cars and Loco tab in Oospore
Well, as we're " spot the 'givens and druthers' of the ideas" .... Car inventory can have a picture on it like the "media loco roster" for Decoder-pro ? Adding columns can be great so one can add
By
Enzo Fortuna
·
#153413
·
|
Locked
Re: UK 3 aspect signal with feather using NCE PowerCab and TrainTech signal
Thanks Ken Sticking to the numbering of my points 2. I've tried Start of Day to the relevant board, with both 'No Action' or 'Saved Position' - with no success - still the red X on switch on 3. Re the
By
Torben Cox
·
#153412
·
|
Locked
Re: Injecting a delay between turnout operations
Dave, Thank ycallinou very much for persevering with me.? Where I am at is as follows - I cannot find how to print out a Logix as you have so you will have to take my words for this.? The times are
By
Iain
·
#153411
·
|
Locked
Re: panel xml file corrupted
Jim, Based on your use of the sensor Property, I concluded that you were avoiding setting up a structure to keep track of the application specific listeners. There is an alternate form for adding a
By
Dave Sand
·
#153410
·
|
Locked
Re: Dispatcher - SML - auto-allocation problem
Thanks Steve, is there any particular program I can use on Windows to edit the file? I seem to remember notepad gives a very weird format. I will take out all the stop sensors from the sections and
By
Mitchell
·
#153409
·
|
Locked
Re: Injecting a delay between turnout operations
Iain, Sounds like you have something else happening. Here is a simple Logix with the delay settings: IX:AUTO:0001C1 Delay Turnout Test [x] R1 IF Sensor "Reset" state is "Sensor Active" THEN On Change
By
Dave Sand
·
#153408
·
|
Locked
Trainfest Milwaukee This weekend
Good Morning All Are there any planned meetings for JMRI users this weekend in Milwaukee at trainfest? Paul V
By
Paul V
·
#153407
·
|
Locked
Re: UK 3 aspect signal with feather using NCE PowerCab and TrainTech signal
Torben, A couple of points. 1. If you get a red X or non-icon on the panel, that means the sensor or turnout has not been set. Meaning it is UNKNOWN, so no icon. So it seems that you would need to
By
Ken Cameron
·
#153406
·
|
Locked
Re: Added sensors and logix to panels. The sensors and logix have disappeared
When I open PanelPro with a different profile, everything is fine. So it's something in that profile -- that's easy enough to fix. So it was a false alarm after all. Thanks all. Scott Walton
By
Scott Walton
·
#153405
·
|
Locked
Re: Mobile Control II and Side bottons
Jim and Roland, Could you verify the Kernel version and Build number of your devices to see if there's something different there? You can find these out via the standard Android Settings 'app' and
By
Matthew Harris
·
#153404
·
|
Locked
Re: UK 3 aspect signal with feather using NCE PowerCab and TrainTech signal
Hi Steve This thread has been v. useful in getting my N gauge BR2003 feather signal working - I too am using CBUS and turnout commands.? Having to use a 2nd turnout command to switch to Zero aspect
By
Torben Cox
·
#153403
·
|
Locked
Re: Injecting a delay between turnout operations
Yes I plan to make up some thin (2") modules to insert between main modules with a pair of signals on. These will either provide signals for unsignalled modules or intermediate between modules. These
By
Mike
·
#153402
·
|
Locked
Re: Injecting a delay between turnout operations
Thank you David.? Tried extending the times and setting them to cascade. Good idea, but it doesn't work for me.? Got up to 20, 40,60 and it still all goes immediately in a rush.
By
Iain
·
#153401
·
|
Locked
Re: panel xml file corrupted
Many thanks ¨C great support from the team once again Sent from Mail<https://go.microsoft.com/fwlink/?LinkId=550986> for Windows 10 ________________________________ Sent: Friday, November 9, 2018
By
James Anderson
·
#153400
·
|
Locked
Re: panel xml file corrupted
Jim, I have created a solution that appears to work. I will post it with an explanation in the (US) morning . Dave Sand
By
Dave Sand
·
#153399
·
|
Locked
Re: panel xml file corrupted
Hi I created the code if that helps and can hopefuly test any changes you sugest.
By
James Anderson
·
#153398
·
|
Locked
Re: NCE not reading AIU
Michael, Use the Show Cabs command from the NCE menu to see if your Power Pro can see the two AIUs and if so at what cab bus addresses. AIU 50: NS784 to NS797. DIP Switches 1-6: on,off,on,on,off,off
By
Dave Heap
·
#153397
·
|
Locked
Re: Layout Editor, too much for RPi3?
ugh. I figured it out. It's nothing interesting and I'm sorry I wasted everyone's time on it. I appreciate some of the tips along the way for reducing the included anyrail elements. I think some
By
josh bernardini
·
#153396
·
|
Locked
Re: NCE not reading AIU
Michael, It is very important to check the return values from the queries to your AIUs. Make sure you tick the "Show Raw Data" checkbox in the Command Monitor. Please tell us what return values you
By
Dave Heap
·
#153395
·
|
Locked
Experts requested
Are there any experts in the Oklahoma City area?? How about any experts coming to the Oklahoma City Train Show on Dec 1st and 2nd? We are looking for someone to give a clinic at the National N Scale
By
Bruce Alcock
·
#153394
·
|