¿ªÔÆÌåÓý

Date
Locked WiThrottle Questions.
Background: We have a large O Scale club using NCE for our DCC. We have several people now who use their phone or tablet to run trains using the JMRI WiThrottle feature. Some use the Apple WiThrottle
By yooper_from_49827 · #137980 ·
Locked Re: Problem programming higher CVs
Just to be clear. If you have NCE Power Pro system, and want to program Tsunami or any other decoder with CV numbers above 255 (Except ESU Loksound) you will need do one of the following: 1. Switch
By thomasmclae · #137978 ·
Locked Re: Z21 Users Please test
Tim, I see two addresses being operated there, 837 and 2203, were those both being operated by Engine Driver? At the end of the log, the last operation request for each locomotive was properly
By Paul Bender · #137979 ·
Locked Re: Operations: No space despite cars to be pulled
Ooops. Your question made me realize that I was having this conversation after apparently being misled by someone (maybe the engineers) into believing this is a problem. It appears now that I am
By Phil in gorgeous Young Harris · #137977 ·
Locked Re: Z21 Users Please test
You will need to be more specific. What error are you getting? Paul
By Paul Bender · #137976 ·
Locked Re: Z21 Users Please test
That is a difference in interpretation of the XPressNet protocol, and has been a long standing issue when mixing hardware from Lenz and Roco. We have always used the Lenz interpretation of the
By Paul Bender · #137975 ·
Locked Re: Z21 Users Please test
Paul as requested. Tim XPressNet Tunnel Message: Mobile Decoder Operations Request: Set Address: 837 To Speed Step 70 and direction Forward In 128 speed step mode. XPressNet Tunnel Reply: EF C3 45 04
By Tim Venton · #137974 ·
Locked Re: Z21 Users Please test
Trying out this nightly build version, I get a problem opening my panel. I'm using the Z21 for loco control and point control, plus MERG Cbus to control more points. Using the production version,
By Tim Venton · #137973 ·
Locked Re: help required to configure JMRI for DIY controller interface
What you do internal to your node is separate from the protocol on the line. For example, you could keep the current status in memory, then compare it when something new is written over the line. That
By Bob Jacobsen · #137972 ·
Locked Re: Car Location Printout
Regarding car locations, I use Excel (older version, 2000) to import the car roster export. Before pre-building any trains for an Ops Session, I do this (Export) then create a spreadsheet with two
By Phil in gorgeous Young Harris · #137971 ·
Locked Re: Z21 Users Please test
Ok, so the question we need to answer with that problem is where are we loosing the connection. It could be between the PC and the Z21, but it could also be between the PC and Engine Driver. One thing
By Paul Bender · #137970 ·
Locked Re: Operations: No space despite cars to be pulled
Phil Is this the build report that works, or the one that fails? Dan
By Dan Boudreau · #137969 ·
Locked Re: JMRI in edit only mode
Sudden memory: Go to Preferences->Defaults and check that NCE is selected for everything, rather than Internal. -- Dave in Australia
By Dave Heap · #137968 ·
Locked Re: Car Location Printout
Norman, Instead of sending the file to the printer, try the "Microsoft XPS Document Writer" and send the output to me to review. You might have a printer that doesn't quite work right with JMRI. Dan
By Dan Boudreau · #137967 ·
Locked Re: JMRI in edit only mode
The "nce.NceConnectionStatus INFO - NCE EPROM revision = 7.3.0" in the log below indicates your drivers, jumpers, baud rate and JMRI settings are correct and that JMRI can communicate with your NCE
By Dave Heap · #137966 ·
Locked Re: help required to configure JMRI for DIY controller interface
Geoff CMRI communication is well defined in this document: https://www.nmra.org/sites/default/files/standards/sandrp/Other_Specifications/lcs-9.10.1_cmrinet_v1.1.pdf There are four special characters
By Blair · #137964 ·
Locked Re: Problem programming higher CVs
Due to a firmware problem, the NCE Power Pro is incapable of correctly programming CVs>256 in Program Track mode (a CV<256 will be reprogrammed instead of the correct one). However you can program
By Dave Heap · #137965 ·
Locked Re: Z21 Users Please test
Update, tried WiThrottle (Android), starts loco going, but loses it, no control at all. Tim
By Tim Venton · #137963 ·
Locked Re: Z21 Users Please test
OK thanks Paul. Throttle works, as I would expect it too. I am unable to test any programming as I don't use the Z21 for that purpose. Now onto the next but minor problem. I have done a workaround,
By Tim Venton · #137962 ·
Locked JMRI 4.7.6 and apologies
First apologies for my tirade about the new version. I could have been more tactful. As for 4.7.6, after about a day of testing and tries, I have given up on it, and gone back to 4.6.0, and all is