¿ªÔÆÌåÓý

Date
Locked Re: Support for higher speed step => lower speed
There¡¯s actually a bunch of complicated code in JMRI to _prevent_ what you want to do. The reason dates back 15 years to some NMRA dicta. It might be time to get past that and add a checkbox to the
By Bob Jacobsen · #130583 ·
Locked Support for higher speed step => lower speed
Hello all, It seems I want to do something that's not intended, and I'm wondering if there's a way to do this neatly. I'm trying to use JMRI (decoderpro) 4.0-r29647 to program a speed curve in a
By whmvd · #130582 ·
Locked Re: Track Power
Group: We've touched on the R-G issue with the track on the model board. While R-G is the most common color vision problem some have a total color identification problem. There is a test that an eye
By Jim Albanowski <jimalbanowski@...> · #130581 ·
Locked Re: Rotate whole panel
Ken Is there any form of textual table form of export and import for the information required? It occurs to me that if there was, one might be able to manipulate the info in a spreadsheet, or text
By Blair · #130580 ·
Locked Re: Track Power
It is a standard practice for panels with combined lamps and pushbuttons to have the lamp show the current status, or feedback from the controlled device, (Red = off, the abnormal state / Green = on,
By James Kelly <jwkelly_49@...> · #130579 ·
Locked Re: Track Power
In addition to Gerry¡¯s comments, hovering the mouse over button displays a tooltip ¡°Layout power On. Click to turn off.¡± if the power is on, and ¡°Layout power Off. Click to turn on.¡± if the
By Randall Wood <rhwood@...> · #130578 ·
Locked Re: Track Power
Peter, Red icon with the word OFF - means the power is off - Those who are colour blind cannot see the difference between red and green. So Green Icon with ON shows the power is ON. Say G'Day to
By Gerry <gerrymmr@...> · #130577 ·
Locked Re: Track Power
It does seem a little strange to have a Red Icon with the word Off to turn On the track power and then a Green Icon with the work On to turn Off the track power. I am afraid the logic beats this old
By Peter Prewett · #130576 ·
Locked Re: Add Loco to Roster with 2 decoders
Dave, Thanks for the trick with the long and short addresses for multiple decoders within one engine. I was fiddling with cumbersomely positioned jumpers all the time when I needed to program
By whmvd · #130575 ·
Locked Re: Sprog
Yes, known issue. I believe it is being addressed. - Nigel
By Nigel Cliffe · #130574 ·
Locked Sprog
Hi, Just upgraded JMRI to 4.5.4 with my old xp computer with a USB Sprog, never had a problem until now, I only use DecoderPro on this machine but since the upgrade I cannot use the built in
By bjw@... · #130573 ·
Locked Re: Multiple JMRI computers on one layout
Dale, That's a different situation than using the JMRIClient with the SimpleServer. In the JMRIClient/SimpleServer case, only one computer is actually connected to the layout and that connection is
By Paul Bender · #130572 ·
Locked Re: Mac OS upgrade now Decoder Pro not working
I just loaded latest version on to my MAC. No other version was installed. I have the latest version of JAVA installed. Nothing loads. Any suggestions?
By Albert Matzelle Jr · #130571 ·
Locked Re: Operations: Interchange Tracks & Car Movement
Hi Mike, Is your issue cars on interchange tracks that don't belong there, or cars on interchange tracks that don't move? More below. ---In jmriusers@..., <mcerpsligo@...> wrote
By Dan Boudreau · #130570 ·
Locked Re: Rotate whole panel
Sadly doing this is not easy. Each item needs to rotate 180 degrees. Then you need to translate every x and y top to bottom and left to right. I recall doing this sort of thing once but that was many
By Ken Cameron · #130569 ·
Locked Re: Add Loco to Roster with 2 decoders
Thank you all for your information and suggestions. I worked with the system today and just used the NCE D405SR as the roster listed decoder and ignored the sound decoder completely. I found that the
By Steve Mitchell · #130568 ·
Locked Re: Automation/Automatic running of Dapol seamphore signals
Hi Iain As long as you have your layout in a layout editor panel you just need to add the signals to anchor points and auto-discover the logic. As long as there is a path between signals on the
By Suzie Tall · #130567 ·
Locked Re: Multiple JMRI computers on one layout
I periodically run 2 layout attached computers with the exact same PanelPro panels and logic simultaneously without seeing any problems. I have the same Layout Editor panel open on both and can
By Dale Gloer · #130566 ·
Locked Rotate whole panel
So the layout owner has decided to move the main JMRI display screen to the opposite side of the room. This means that the layout editor panel is now upside down and back to front (ie: 180
By Pete Brownlow · #130565 ·
Locked Re: signal mast problem in latest test build
Robin, I confirmed what you see on macOS as well and created Issue #2058 https://github.com/JMRI/JMRI/issues/2058 for it on GitHub. Will look into it and hope we can fix this soon. Egbert