Locked Issues with Pi-SPROG / JMRI setup
Hello- Not the most complex questions, but I cannot find answers to this anywhere. I have a Pi-SPROG and it returns 123 for almost every CV I read on any Locomotive/device. This CVs are right on my
By Nathan Tableman · #153424 ·
Locked How to install JMRI using OPENJDK
Greetings, I have installed JMRI 4.14.4 on my main computer running OpenJDK 11.0.1 and all is running fine. I have been using this computer for JMRI for several years.? I'm building a new computer
By Peter Jerkewitz · #153423 ·
Locked Re: UK 3 aspect signal with feather using NCE PowerCab and TrainTech signal
Hi Steve I haven't come across the video so will check it out. It's most likely that it is the Signal Mast Logic table that I haven't understood regarding feathers Thanks Torben
By Torben Cox · #153422 ·
Locked Re: UK 3 aspect signal with feather using NCE PowerCab and TrainTech signal
Hi Torben, If any of the conditional sensors to the logix are unknown, then it won't be able to calculate so worth checking the appearance in the Signal Mast Logic table, then in sensor table for any
By Steve Young · #153421 ·
Locked Re: Injecting a delay between turnout operations
David, Thank you very much.? What you suggest is achievable, but not using SP1a as it is used in many places and may be set in many instances (it is a part of a station platform - so a lot of
By Iain · #153420 ·
Locked Re: Mobile Control II and Side bottons
Matt: There is a difference in the two... Kernel on the early MCII is the same as you show. However the second is different with a #154 not #105. Build also has a difference 20160517 not 20150526.
By jimalbanowski · #153419 ·
Locked Re: Injecting a delay between turnout operations
Iain, After further review, it appears that things are working exactly as expected. As I mentioned before, each Action is performed in sequence with delayed Actions queued. From a Logix processing
By Dave Sand · #153418 ·
Locked Re: panel xml file corrupted
Thanks - code in and working - I'll do some testing over the weekend and let you know how it has gone. It's a steep learning curve for me at the moment soI really appreciate all your help.
By James Anderson · #153417 ·
Locked Re: Injecting a delay between turnout operations
David,? Sorry the two early signals are 36 and 38!? Don't think that matters really but it does now tie up with the NCE output! Iain
By Iain · #153416 ·
Locked Re: Injecting a delay between turnout operations
David, Thank you.? Browse as requested - another thing I didn't know about!? Comments in square brackets - this is the same as the NCE Command Monitor output I put in the last message.
By Iain · #153415 ·
Locked Re: Injecting a delay between turnout operations
Iain, The Select menu for a Logix contains a Browse option under the Edit option. This will display the Logix in a separate window. The text in the window can be selected and copied. If you post the
By Dave Sand · #153414 ·
Locked Re: Adding new "info" field to the Cars and Loco tab in Oospore
Well, as we're " spot the 'givens and druthers' of the ideas" .... Car inventory can have a picture on it like the "media loco roster" for Decoder-pro ? Adding columns can be great so one can add
By Enzo Fortuna · #153413 ·
Locked Re: UK 3 aspect signal with feather using NCE PowerCab and TrainTech signal
Thanks Ken Sticking to the numbering of my points 2. I've tried Start of Day to the relevant board, with both 'No Action' or 'Saved Position' - with no success - still the red X on switch on 3. Re the
By Torben Cox · #153412 ·
Locked Re: Injecting a delay between turnout operations
Dave, Thank ycallinou very much for persevering with me.? Where I am at is as follows - I cannot find how to print out a Logix as you have so you will have to take my words for this.? The times are
By Iain · #153411 ·
Locked Re: panel xml file corrupted
Jim, Based on your use of the sensor Property, I concluded that you were avoiding setting up a structure to keep track of the application specific listeners. There is an alternate form for adding a
By Dave Sand · #153410 ·
Locked Re: Dispatcher - SML - auto-allocation problem
Thanks Steve, is there any particular program I can use on Windows to edit the file? I seem to remember notepad gives a very weird format. I will take out all the stop sensors from the sections and
By Mitchell · #153409 ·
Locked Re: Injecting a delay between turnout operations
Iain, Sounds like you have something else happening. Here is a simple Logix with the delay settings: IX:AUTO:0001C1 Delay Turnout Test [x] R1 IF Sensor "Reset" state is "Sensor Active" THEN On Change
By Dave Sand · #153408 ·
Locked Trainfest Milwaukee This weekend
Good Morning All Are there any planned meetings for JMRI users this weekend in Milwaukee at trainfest? Paul V
By Paul V · #153407 ·
Locked Re: UK 3 aspect signal with feather using NCE PowerCab and TrainTech signal
Torben, A couple of points. 1. If you get a red X or non-icon on the panel, that means the sensor or turnout has not been set. Meaning it is UNKNOWN, so no icon. So it seems that you would need to
By Ken Cameron · #153406 ·
Locked Re: Added sensors and logix to panels. The sensors and logix have disappeared
When I open PanelPro with a different profile, everything is fine. So it's something in that profile -- that's easy enough to fix. So it was a false alarm after all. Thanks all. Scott Walton
By Scott Walton · #153405 ·