Locked Re: DCS240 JMRI

 

My programing track is less than 3ft away. We upgrade from a dcs 200. But we also have 5 sections each control 30 ft at max. My DCS240 is the main and controls antennas, programing track, and a 2 track main roughly 8ft long.
Sent from Yahoo Mail on Android

On Mon, Aug 14, 2017 at 10:00 PM, afbombers1942@... [jmriusers]<jmriusers@...> wrote: ?
I would like to add some interesting observations here, I also hooked up a new dcs240 from a dcs 100.

Initially I had a 30 ft run from the command station on 12 gauge running to a dcc specialties programming booster with the laptop hooked up to a up5.

After hooking up the dcs 240 I first tried the locobuffer configuration with no luck kept getting a programmer was busy error. Next I removed the power booster and tried a 30ft usb cable with a repeater tied in to it with the same problem.

At the end of the day I has to use a short usb and a make shift programming track thst is now within 5 feet if the command station in order to not get a programmer busy error......tried just about every combination between the locobuffer and built in programmer in the command station.

Seems to be an issue with long runs of wire and the command station/Jmri being confused.

Tristan
#yiv7289096791 #yiv7289096791 -- #yiv7289096791ygrp-mkp {border:1px solid #d8d8d8;font-family:Arial;margin:10px 0;padding:0 10px;}#yiv7289096791 #yiv7289096791ygrp-mkp hr {border:1px solid #d8d8d8;}#yiv7289096791 #yiv7289096791ygrp-mkp #yiv7289096791hd {color:#628c2a;font-size:85%;font-weight:700;line-height:122%;margin:10px 0;}#yiv7289096791 #yiv7289096791ygrp-mkp #yiv7289096791ads {margin-bottom:10px;}#yiv7289096791 #yiv7289096791ygrp-mkp .yiv7289096791ad {padding:0 0;}#yiv7289096791 #yiv7289096791ygrp-mkp .yiv7289096791ad p {margin:0;}#yiv7289096791 #yiv7289096791ygrp-mkp .yiv7289096791ad a {color:#0000ff;text-decoration:none;}#yiv7289096791 #yiv7289096791ygrp-sponsor #yiv7289096791ygrp-lc {font-family:Arial;}#yiv7289096791 #yiv7289096791ygrp-sponsor #yiv7289096791ygrp-lc #yiv7289096791hd {margin:10px 0px;font-weight:700;font-size:78%;line-height:122%;}#yiv7289096791 #yiv7289096791ygrp-sponsor #yiv7289096791ygrp-lc .yiv7289096791ad {margin-bottom:10px;padding:0 0;}#yiv7289096791 #yiv7289096791actions {font-family:Verdana;font-size:11px;padding:10px 0;}#yiv7289096791 #yiv7289096791activity {background-color:#e0ecee;float:left;font-family:Verdana;font-size:10px;padding:10px;}#yiv7289096791 #yiv7289096791activity span {font-weight:700;}#yiv7289096791 #yiv7289096791activity span:first-child {text-transform:uppercase;}#yiv7289096791 #yiv7289096791activity span a {color:#5085b6;text-decoration:none;}#yiv7289096791 #yiv7289096791activity span span {color:#ff7900;}#yiv7289096791 #yiv7289096791activity span .yiv7289096791underline {text-decoration:underline;}#yiv7289096791 .yiv7289096791attach {clear:both;display:table;font-family:Arial;font-size:12px;padding:10px 0;width:400px;}#yiv7289096791 .yiv7289096791attach div a {text-decoration:none;}#yiv7289096791 .yiv7289096791attach img {border:none;padding-right:5px;}#yiv7289096791 .yiv7289096791attach label {display:block;margin-bottom:5px;}#yiv7289096791 .yiv7289096791attach label a {text-decoration:none;}#yiv7289096791 blockquote {margin:0 0 0 4px;}#yiv7289096791 .yiv7289096791bold {font-family:Arial;font-size:13px;font-weight:700;}#yiv7289096791 .yiv7289096791bold a {text-decoration:none;}#yiv7289096791 dd.yiv7289096791last p a {font-family:Verdana;font-weight:700;}#yiv7289096791 dd.yiv7289096791last p span {margin-right:10px;font-family:Verdana;font-weight:700;}#yiv7289096791 dd.yiv7289096791last p span.yiv7289096791yshortcuts {margin-right:0;}#yiv7289096791 div.yiv7289096791attach-table div div a {text-decoration:none;}#yiv7289096791 div.yiv7289096791attach-table {width:400px;}#yiv7289096791 div.yiv7289096791file-title a, #yiv7289096791 div.yiv7289096791file-title a:active, #yiv7289096791 div.yiv7289096791file-title a:hover, #yiv7289096791 div.yiv7289096791file-title a:visited {text-decoration:none;}#yiv7289096791 div.yiv7289096791photo-title a, #yiv7289096791 div.yiv7289096791photo-title a:active, #yiv7289096791 div.yiv7289096791photo-title a:hover, #yiv7289096791 div.yiv7289096791photo-title a:visited {text-decoration:none;}#yiv7289096791 div#yiv7289096791ygrp-mlmsg #yiv7289096791ygrp-msg p a span.yiv7289096791yshortcuts {font-family:Verdana;font-size:10px;font-weight:normal;}#yiv7289096791 .yiv7289096791green {color:#628c2a;}#yiv7289096791 .yiv7289096791MsoNormal {margin:0 0 0 0;}#yiv7289096791 o {font-size:0;}#yiv7289096791 #yiv7289096791photos div {float:left;width:72px;}#yiv7289096791 #yiv7289096791photos div div {border:1px solid #666666;min-height:62px;overflow:hidden;width:62px;}#yiv7289096791 #yiv7289096791photos div label {color:#666666;font-size:10px;overflow:hidden;text-align:center;white-space:nowrap;width:64px;}#yiv7289096791 #yiv7289096791reco-category {font-size:77%;}#yiv7289096791 #yiv7289096791reco-desc {font-size:77%;}#yiv7289096791 .yiv7289096791replbq {margin:4px;}#yiv7289096791 #yiv7289096791ygrp-actbar div a:first-child {margin-right:2px;padding-right:5px;}#yiv7289096791 #yiv7289096791ygrp-mlmsg {font-size:13px;font-family:Arial, helvetica, clean, sans-serif;}#yiv7289096791 #yiv7289096791ygrp-mlmsg table {font-size:inherit;font:100%;}#yiv7289096791 #yiv7289096791ygrp-mlmsg select, #yiv7289096791 input, #yiv7289096791 textarea {font:99% Arial, Helvetica, clean, sans-serif;}#yiv7289096791 #yiv7289096791ygrp-mlmsg pre, #yiv7289096791 code {font:115% monospace;}#yiv7289096791 #yiv7289096791ygrp-mlmsg * {line-height:1.22em;}#yiv7289096791 #yiv7289096791ygrp-mlmsg #yiv7289096791logo {padding-bottom:10px;}#yiv7289096791 #yiv7289096791ygrp-msg p a {font-family:Verdana;}#yiv7289096791 #yiv7289096791ygrp-msg p#yiv7289096791attach-count span {color:#1E66AE;font-weight:700;}#yiv7289096791 #yiv7289096791ygrp-reco #yiv7289096791reco-head {color:#ff7900;font-weight:700;}#yiv7289096791 #yiv7289096791ygrp-reco {margin-bottom:20px;padding:0px;}#yiv7289096791 #yiv7289096791ygrp-sponsor #yiv7289096791ov li a {font-size:130%;text-decoration:none;}#yiv7289096791 #yiv7289096791ygrp-sponsor #yiv7289096791ov li {font-size:77%;list-style-type:square;padding:6px 0;}#yiv7289096791 #yiv7289096791ygrp-sponsor #yiv7289096791ov ul {margin:0;padding:0 0 0 8px;}#yiv7289096791 #yiv7289096791ygrp-text {font-family:Georgia;}#yiv7289096791 #yiv7289096791ygrp-text p {margin:0 0 1em 0;}#yiv7289096791 #yiv7289096791ygrp-text tt {font-size:120%;}#yiv7289096791 #yiv7289096791ygrp-vital ul li:last-child {border-right:none !important;}#yiv7289096791


[Non-text portions of this message have been removed]


Locked Re: DCS240 JMRI

 

I would like to add some interesting observations here, I also hooked up a new dcs240 from a dcs 100.

Initially I had a 30 ft run from the command station on 12 gauge running to a dcc specialties programming booster with the laptop hooked up to a up5.

After hooking up the dcs 240 I first tried the locobuffer configuration with no luck kept getting a programmer was busy error. Next I removed the power booster and tried a 30ft usb cable with a repeater tied in to it with the same problem.

At the end of the day I has to use a short usb and a make shift programming track thst is now within 5 feet if the command station in order to not get a programmer busy error......tried just about every combination between the locobuffer and built in programmer in the command station.

Seems to be an issue with long runs of wire and the command station/Jmri being confused.

Tristan


Locked Re: DCS240 JMRI

 

I'm running 4.8..,

On Aug 14, 2017, at 9:28 PM, DAVID KLEMM davidklemm7511@... [jmriusers] <jmriusers@...> wrote:

What version of JMRI are you running? The 240 was addressed around 4.7.2.

David Klemm
Sent from my iPhone 7 Plus
________________________________
From: jmriusers@... <jmriusers@...> on behalf of ronmerrill69@... [jmriusers] <jmriusers@...>
Sent: Monday, August 14, 2017 7:12:32 PM
To: jmriusers@...
Subject: [jmriusers] DCS240 JMRI



I installed a DCS240 on our Club layout. I did my research on the new system, reading online that the DCS240 used the same drivers as the PR3, so I installed just prior to a week of vacation. the programing track was reading and operating normally, main line was operating normally, on my return fellow club members reported that programing track was not working. I rechecked configuration. all settings were as I had set them, it has done a couple of things, 1) it read each cv then stopped (306) then next cv, same thing. 2) it completely stopped reading (306). fixes uninstall/redo drivers. what does everyone else think







[Non-text portions of this message have been removed]



------------------------------------

------------------------------------


------------------------------------

Yahoo Groups Links



Locked Re: DCS240 JMRI

 

I get that error when the PR3 is in the wrong mode on my home set up with a DCS200.

Our club uses the 240 just for running the layout so we haven't run in to this with it. So not sure how to change modes like I can with a stand alone PR3.

David Klemm
Sent from my iPhone 7 Plus
________________________________
From: jmriusers@... <jmriusers@...> on behalf of Ron Merrill ronmerrill69@... [jmriusers] <jmriusers@...>
Sent: Monday, August 14, 2017 8:34:16 PM
To: jmriusers@...
Subject: Re: [jmriusers] DCS240 JMRI



Will need to get back with you, but I installed newest version that was not a test version, I think 4.8 production release

Sent from Yahoo Mail on Android

On Mon, Aug 14, 2017 at 9:28 PM, DAVID KLEMM davidklemm7511@... [jmriusers]<jmriusers@...> wrote: What version of JMRI are you running? The 240 was addressed around 4.7.2.

David Klemm
Sent from my iPhone 7 Plus
________________________________
From: jmriusers@... <jmriusers@...> on behalf of ronmerrill69@... [jmriusers] <jmriusers@...>
Sent: Monday, August 14, 2017 7:12:32 PM
To: jmriusers@...
Subject: [jmriusers] DCS240 JMRI

I installed a DCS240 on our Club layout. I did my research on the new system, reading online that the DCS240 used the same drivers as the PR3, so I installed just prior to a week of vacation. the programing track was reading and operating normally, main line was operating normally, on my return fellow club members reported that programing track was not working. I rechecked configuration. all settings were as I had set them, it has done a couple of things, 1) it read each cv then stopped (306) then next cv, same thing. 2) it completely stopped reading (306). fixes uninstall/redo drivers. what does everyone else think

[Non-text portions of this message have been removed]

[Non-text portions of this message have been removed]

------------------------------------

------------------------------------

------------------------------------

Yahoo Groups Links







[Non-text portions of this message have been removed]


Locked Re: DCS240 JMRI

 

Did you do the update v.3 on the DCs240?
On Aug 14, 2017, at 8:12 PM, ronmerrill69@... [jmriusers] <jmriusers@...> wrote:

I installed a DCS240 on our Club layout. I did my research on the new system, reading online that the DCS240 used the same drivers as the PR3, so I installed just prior to a week of vacation. the programing track was reading and operating normally, main line was operating normally, on my return fellow club members reported that programing track was not working. I rechecked configuration. all settings were as I had set them, it has done a couple of things, 1) it read each cv then stopped (306) then next cv, same thing. 2) it completely stopped reading (306). fixes uninstall/redo drivers. what does everyone else think

[Non-text portions of this message have been removed]


[Non-text portions of this message have been removed]


Locked Re: DCS240 JMRI

 

Will need to get back with you, but I installed newest version that was not a test version, I think 4.8 production release

Sent from Yahoo Mail on Android

On Mon, Aug 14, 2017 at 9:28 PM, DAVID KLEMM davidklemm7511@... [jmriusers]<jmriusers@...> wrote: What version of JMRI are you running?? The 240 was addressed around 4.7.2.

David Klemm
Sent from my iPhone 7 Plus
________________________________
From: jmriusers@... <jmriusers@...> on behalf of ronmerrill69@... [jmriusers] <jmriusers@...>
Sent: Monday, August 14, 2017 7:12:32 PM
To: jmriusers@...
Subject: [jmriusers] DCS240 JMRI



I installed a DCS240 on our Club layout. I did my research on the new system, reading online that the DCS240 used the same drivers as the PR3, so I installed just prior to a week of vacation. the programing track was reading and operating normally, main line was operating normally, on my return fellow club members reported that programing track was not working. I rechecked configuration. all settings were as I had set them, it has done a couple of things, 1) it read each cv then stopped (306) then next cv, same thing. 2) it completely stopped reading (306). fixes uninstall/redo drivers. what does everyone else think

[Non-text portions of this message have been removed]









------------------------------------

------------------------------------


------------------------------------

Yahoo Groups Links






[Non-text portions of this message have been removed]


Locked 'signalHeadManagerInstance' not found in 4.9.2?

 

Upgraded from 4.9.1 to 4.9.2 and now it does not like this line from jmridefaults.py and stops dead before showing any of my Layout Editor Panels. Any thoughts?
2017-08-14 21:18:35,692 script.JmriScriptEngineManager ERROR - Exception creating jython system objects [main]

javax.script.ScriptException: AttributeError: type object 'jmri.InstanceManager' has no attribute 'signalHeadManagerInstance' in <script> at line number 21


Randy


Locked Re: DCS240 JMRI

 

What version of JMRI are you running? The 240 was addressed around 4.7.2.

David Klemm
Sent from my iPhone 7 Plus
________________________________
From: jmriusers@... <jmriusers@...> on behalf of ronmerrill69@... [jmriusers] <jmriusers@...>
Sent: Monday, August 14, 2017 7:12:32 PM
To: jmriusers@...
Subject: [jmriusers] DCS240 JMRI



I installed a DCS240 on our Club layout. I did my research on the new system, reading online that the DCS240 used the same drivers as the PR3, so I installed just prior to a week of vacation. the programing track was reading and operating normally, main line was operating normally, on my return fellow club members reported that programing track was not working. I rechecked configuration. all settings were as I had set them, it has done a couple of things, 1) it read each cv then stopped (306) then next cv, same thing. 2) it completely stopped reading (306). fixes uninstall/redo drivers. what does everyone else think

[Non-text portions of this message have been removed]





[Non-text portions of this message have been removed]


Locked Re: DCS240 JMRI

 

no, I'm asking if its a valid fix


Locked Re: Importing Layout Scematic from Anyrail

 

Ray,

I believe AnyRail lets you export a layout to an image file (JPG, PNG?). If so, then the easiest thing to do would be to place that image onto your panel as an icon.


I've built schmatics of my layout in Microsoft PowerPoint. Then exported as a .PNG file and placed it on my panel as an icon. There's a picture of my CTC Panel in the folder Bob Z CTC Panel.


Bob Z


Locked Re: DCS240 JMRI

 

ronmerrill69
Am I reading this correct? You fixed the problem by uninstalling the driver and reinstalling it,
Walt


Locked DCS240 JMRI

 

I installed a DCS240 on our Club layout. I did my research on the new system, reading online that the DCS240 used the same drivers as the PR3, so I installed just prior to a week of vacation. the programing track was reading and operating normally, main line was operating normally, on my return fellow club members reported that programing track was not working. I rechecked configuration. all settings were as I had set them, it has done a couple of things, 1) it read each cv then stopped (306) then next cv, same thing. 2) it completely stopped reading (306). fixes uninstall/redo drivers. what does everyone else think


Locked Re: Slot monitor is blank

 

Terry: But when we ask a question about how something is set " No change" is not how it is set!


Locked Re: Importing Layout Scematic from Anyrail

 

On the PanelPro main menu, Panels menu, Load Panels... item. Then navigate to your XML file to select it and open.

The AnyRail process is a bit rough still. If you get any Really Obscure Errors, please
1) post the file so we can track those down and
2) Panels -> Run Script, select the TurnOffXmlValidation.py script, and run it; then try your XML file again.

Bob

On Aug 14, 2017, at 1:04 PM, raypurdy@... [jmriusers] <jmriusers@...> wrote:

Having designed my layout in Anyrail, I have now created a simlfied version and saved it as an XML document so I can import it into Panel Pro to use in Layout or Panel Editor


Locked Re: Slot monitor is blank

 

Bob, Walt, Peter et al. I admire your patience. It is my opinion that people who expect 'no charge' help of any kind should have an attitude that encourages people to provide that help.


Locked Re: Slot monitor is blank

 

Not so much that the entries get changed but how they affect the program can have changed.

As an former remote support computer maintenance person this is the first time I have had a user with a problem refuse to give information when asked for it. I have not responded after the refusal and do not plan on doing so.


I will keep monitoring this thread, hoping for a change in attitude.


Walt


Locked Re: Slot monitor is blank

 

Why would the developers make that possible ?
They'd be making their own problems

I've used JMRI Since
Release 1.8 and never made a preference change all the way up to 4.6
Nor did the new release make the change
Now with 4.8 i have problems ????????
I think the developers need to go back to the drawing board on 4.8




Terry
Visit My Web site@

-----Original Message-----
From: jawhugrps@... [jmriusers] <jmriusers@...>
To: jmriusers <jmriusers@...>
Sent: Mon, Aug 14, 2017 3:59 pm
Subject: Re: [jmriusers] Slot monitor is blank






What you might be missing, Terry, is that JMRI can, when moving from one JMRI version to another, make changes to the configuration profile.

So the fact that you haven't changed the file doesn't mean it isn't different, now, without your knowledge.

Regards,
Billybob











[Non-text portions of this message have been removed]


Locked Re: Slot monitor is blank

 

What you might be missing, Terry, is that JMRI can, when moving from one JMRI version to another, make changes to the configuration profile.

So the fact that you haven't changed the file doesn't mean it isn't different, now, without your knowledge.

Regards,
Billybob


Locked Re: Importing Layout Scematic from Anyrail

 

Ray,

This may be a problem, unless "Anyrail" produces an XML file that is compliant with JMRI's format. If "Anyrail" does provide an acceptable format, they you should be able to open it as a "panel file" under JMRI. If not, then JMRI will just give an error and/or fail to load the panel. I do not have any experience with "Anyrail", so cannot confirm or deny that this will work.

If you run JMRI DecoderPro3, you need to have a "Panel Pro" window open. Select the "File" pulldown menu. Select "Open PanelPro Window".

In JMRI PanelPro, select the "Panels" pulldown menu. Select "Open Panels". Choose the XML file you saved from "Anyrail". If it loads and creates a panel, great. Elsewise, look for a different solution.

Once you get your design loaded, you can modify it within JMRI and save it in JMRI's native panel format. Then go forward using JMRI's saved panel, instead of the "Anyrail" file.

If this doesn't work, then perhaps someone on this list has direct experience and can has different direction to offer...

Regards,
Billybob


Locked Having trouble starting DP with Sprog2v3

 

I have recently purchased a new computer, an iMAC running OS X 10.12.6. I plugged in my Sprog2v3 to the USB port (via a hub). According to the "about this Mac" screen, the computer sees the SPROG. I have also updated Java to the newest version. However, when I start Decoder Pro I get an error message that the program could not find the port. I am mystified as on my old MAC everything worked fine. That computer self-destructed and I lost whatever Decoder Pro files might have been on it. Any assistance would be much appreciated.
Thanks, Tom


Here is the error message:

Unable to create connection "SPROG Programmer" (S). Serial port (none selected) not found.Serial port (none selected) not found. System connection SPROG Programmer provides a null manager for interface jmri.ThrottleManager Unable to run startup actions due to earlier failures.