Keyboard Shortcuts
Likes
- Jmriusers
- Messages
Search
Locked
Re: Exception and other errors? Blocks Signals
Steve,
toggle quoted message
Show quoted text
I have never needed to change signalspeeds.xml. ?I tweak speed assignments for turnouts and blocks to get the signal mast logic to work in special cases. ?For layouts I work with, I set the default diverging turnout speed to medium. Ken describes the logic process in the other response. I want to expand on that a bit. ?The basic signal mast logic concept is: ?The signal mast is Stop/Danger unless a route to a destination mast can be selected. ? Based on the ¡°path" speed and the indication on the next mast, an aspect is selected from the aspects.xml and appearance xml files. ?A key factor for the aspect determination is whether the route is normal or diverging. ?A route is normal if ¡°ALL¡± turnouts are normal. ?It is diverging if ¡°ANY¡± turnout is diverging. Dave Sand On Jul 23, 2019, at 6:04 AM, bluetobits <steve.lomax@...> wrote: |
Locked
Re: JMRI and NCE
What should happen is it shows green thinking there is a connection. Within
10 seconds, it probes the interface to see if it replies right. If that fails, the connection turns red. You should do a cut/paste of the console log again so we can see that the port opened ok. Typical issue at this point (assuming the open worked) is the baud rate doesn't match. Now my next question is to confirm which make of interface and command station you are using. That will help clue me as to the next things to try to explain. The current console log will tell me what you are trying, but that might not be the right match for the hardware you have. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.com www.syracusemodelrr.org |
Locked
Re: JMRI and NCE
Hello Ken C.,
toggle quoted message
Show quoted text
I double checked in Device Manager USB Interface using COMM4. When I start JMRI the Decoder Screen at bottom has NCE connected in green message. When I select a loco to program, the message changes to offline. How can I check that the USB Interface hardware connections are ok? Ken S. -----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Ken Cameron Sent: Tuesday, July 23, 2019 11:37 AM To: [email protected] Subject: Re: [jmriusers] JMRI and NCE Ken S, The cut/paste of the console log you sent shows JMRI asking for COM4, but the system saying COM4 not found. Insure everything is connected and powered up before starting JMRI. Also follow what I said before about using Windows Device Manager to confirm the hardware is really loading up at COM4 and no errors with drivers. We've found that Win10 updates sometimes disables drivers and they need to be loaded again. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.com www.syracusemodelrr.org |
Locked
Re: JMRI and NCE
Ken S,
The cut/paste of the console log you sent shows JMRI asking for COM4, but the system saying COM4 not found. Insure everything is connected and powered up before starting JMRI. Also follow what I said before about using Windows Device Manager to confirm the hardware is really loading up at COM4 and no errors with drivers. We've found that Win10 updates sometimes disables drivers and they need to be loaded again. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.com www.syracusemodelrr.org |
Locked
Re: JMRI and NCE
¿ªÔÆÌåÓýHello Marc, Here is screen I get. ? Ken ? From: [email protected] <[email protected]> On Behalf Of forfoum@... ? Ken, attachements are not permitted and will not come thru.? |
Thanks Paul,
I started this effort by reading the following section on the JMRI site ¡? If I understand correctly, I should be able to run one servo directly connected to the Arduino's 5V, GND and one digital port (mine is connected to port 7). Of the three methods available with the DCC++ sketch, only the third method using the base station "Output" approach should work. This is what I have done, and everything looks great in JMRI, but the servo never moves. But I get your concern about the PWM. As I watch the DCC++ traffic monitor I see only a "Low" then "High" state for the JMRI turnout. And when I hold the servo next to my ear, I hear a "click" when I send the command in JMRI to go "closed" or "thrown". Is there any way I can overcome this in the DCC++ sketch? Richard |
Locked
Re: Cantons / Stop trains in block with red signal
@Dennis
Thank's for your explain, but the question only for DecoderPro as you said : "Decoder Pro might give you the answer also if it has the feature for you to activate."
?
Can you explain to me how to check with DecoderPro,?in which tab ?
?
Thank's
|
Locked
Re: DP feature request
On Jul 23, 2019, at 2:56 AM, Jim Kirwan via Groups.Io <cact25@...> wrote:This is certainly possible, but It may not be very reliable. You are much more likely to change the consist address than the locomotive primary address, and there are many ways to change CV19 without JMRI¡¯s knowledge. In most of those cases, we have no means to verify the current contents of the CV without putting the decoder on the programming track. (The exception is if you have hardware installed that can read CV values on the main ( such as RailCom )). Paul |
Locked
Re: JMRI and NCE
¿ªÔÆÌåÓýHi Marc, ? I did a snip of the screen and I see it is now a jpeg in my Download folder. How do I upload it to the file section? ? Ken ? From: [email protected] <[email protected]> On Behalf Of forfoum@... ? Ken, attachements are not permitted and will not come thru.? |
Locked
Re: JMRI and NCE
¿ªÔÆÌåÓýHello Again, ? The NCE USB interface is connect through the COMM4 port. When I load DecoderPro following screen appears which I have attached. Prior to getting Windows 10 I had Windows 7 Pro and JMRI worked. What do I need to check? How do I determine if USB interface is working? ? Ken Skopp ? ? ? From: [email protected] <[email protected]> On Behalf Of Kenneth Skopp via Groups.Io
Sent: Tuesday, July 23, 2019 6:04 AM To: [email protected] Subject: Re: [jmriusers] JMRI and NCE ? Hello Marc, ? I found the System Console Log. I have attached it below. I now have only one NCE connection now. ? Ken Skopp ? From: [email protected] <[email protected]> On Behalf Of forfoum@... ? On Mon, Jul 22, 2019 at 04:04 PM, Kenneth Skopp wrote:
Do you have a good reason to have a second NCE connection ?? You believe you deleted NCE2(N2).?? Clearly it was not deleted as per this message. 2019-07-23 05:59:00,298 util.Log4JUtil??????????????????????? INFO? - * JMRI log ** [main] 2019-07-23 05:59:00,327 util.Log4JUtil??????????????????????? INFO? - This log is appended to file: C:\Users\Ken\JMRI\log\messages.log [main] 2019-07-23 05:59:00,327 util.Log4JUtil??????????????????????? INFO? - This log is stored in file: C:\Users\Ken\JMRI\log\session.log [main] 2019-07-23 05:59:00,327 apps.AppsBase???????????????????????? INFO? - DecoderPro version 4.16+R6f9aced starts under Java 1.8.0_181 on Windows 10 x86 v10.0 at Tue Jul 23 05:59:00 EDT 2019 [main] 2019-07-23 05:59:00,528 gui3.Apps3??????????????????????????? INFO? - Starting with profile My_JMRI_Railroad.3f3718c5 [main] 2019-07-23 05:59:00,809 node.NodeIdentity???????????????????? INFO ?- Using jmri-kyUuSdgurhNiaayakslegv-3f3718c5 as the JMRI storage identity for profile id 3f3718c5 [AWT-EventQueue-0] 2019-07-23 05:59:00,903 xml.AbstractSerialConnectionConfigXml INFO? - Starting to connect for "NCE" [main] 2019-07-23 05:59:01,278 usbdriver.UsbDriverAdapter??????????? ERROR - Serial port COM4 not found [main] 2019-07-23 05:59:01,278 jmrix.ConnectionConfigManager???????? ERROR - Unable to create jmri.jmrix.nce.usbdriver.configurexml.ConnectionConfigXml for [Element: <connection/>], load returned false [main] 2019-07-23 05:59:01,278 plementation.JmriConfigurationManager ERROR - Exception initializing jmri.jmrix.ConnectionConfigManager: Unable to create several of your connections. [main] 2019-07-23 05:59:01,987 jmri.InstanceManager?????????? ???????ERROR - Should not set default of type jmri.CommandStation to null value [main] 2019-07-23 05:59:01,987 managers.ManagerDefaultSelector?????? WARN? - SystemConnectionMemo for NCE (class jmri.jmrix.nce.NceSystemConnectionMemo) provides a null interface jmri.CommandStation instance [main] 2019-07-23 05:59:01,987 plementation.JmriConfigurationManager ERROR - Exception initializing jmri.managers.ManagerDefaultSelector: System connection NCE provides a null manager for interface jmri.CommandStation [main] 2019-07-23 05:59:02,096 plementation.JmriConfigurationManager ERROR - Exception initializing apps.StartupActionsManager: jmri.util.prefs.InitializationException: Unable to run startup actions due to earlier failures. [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path program: is C:\Program Files (x86)\JMRI\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path preference: is C:\Users\Ken\JMRI\My_JMRI_Railroad\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path profile: is C:\Users\Ken\JMRI\My_JMRI_Railroad\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path settings: is C:\Users\Ken\JMRI\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path home: is C:\Users\Ken\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path scripts: is C:\Users\Ken\JMRI\My_JMRI_Railroad\ [main] 2019-07-23 05:59:05,770 throttle.PowerManagerButton?????????? INFO? - No power manager instance found, panel not active [main]
|
Locked
Re: Exception and other errors? Blocks Signals
The way the masts and the speeds are supposed to work is the logic finds the
next signal. It then considers the speed (from the mast entry for that signal aspect), the speed limit for any blocks or turnout routes between this and that next signal. It then looks at the aspects available for this signal and the speeds and tries to find the best match. The downside is if the combination of paths and speeds don't find a match in the mast, it will pick the slowest/most restrictive aspect. Every now and then, somebody has a layout that finds a combination not matched in the masts and a quick edit is needed. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.com www.syracusemodelrr.org |
Bob:
There is a fix... thought I posted link to the Pi Forum page that lead to the link, now I can't quickly find the fix. I'll try to post photo later but I added a heat sink through the top of the online Pi cases. The heat with JMRI running seems to be under better control than before the fix. Hot to touch but not into the ouch range... It's a for sure that the Pi 4 was released ahead of the distro fully ready... Since the speed increase is noticeable it will be worth the wait for all the software to catch up. Jim Albanowski |
Locked
Re: JMRI and NCE
Ken W,
It is trying to open COM4 for the NCE connection. Use the Windows Device Manager to confirm which COM port it is using and that the driver is ok. Plugging and unplugging the connection at the computer should make it show up and go away from the 'Ports' list in the Device Manager. Right click on the COMx to see if it thinks the driver install is ok. That's in the properties. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.com www.syracusemodelrr.org |
Jim:?? i looked at the Pi 4 a few days ago, there still seems to be some thermal issues with overheating when the CPU gets to a high rate of utilization, it isn't helping that the Pi 4 case has inadequate ventilation.??
I too want to get my hands on one but I'll wait till the issue is resolved.?? There appears to be a firmware fix in the offing to address it.?? |
Locked
Re: Exception and other errors? Blocks Signals
Hi again Dave, Ken and all
Dave: I have tried your suggestion and this really helps to have a better understanding of signal mast logic. The strange routing behaviour issue at cuewait siding is still causing signal? problems, as is a similar the issue at slippery slope. This may be because I have not fully blocked the mine section and set up block occupancy sensors and signal masts for that section. I was hoping this would not be necessary. I have reverted to a earlier save of my layout which uses single head masts at the xovers and the aspects seem to function more predictably. I don't need double heads as I don't want to automatic trains to use the mining section in any event, but do need to stop auto trains from entering turning loops that are currently being used for manual mine traffic. I was using the double aspect signals to try to understand why the main line locos were reducing speed to 15 over the xover section despite green signals.? I'm not sure I have fully grasped the process behind the SML or built my layout to be compatible or at least "comfortable" with it but with help and advice from yourself and others, I'm on the way to gaining a basic understanding. Ken: I hadn't realised this. This is great and could be the root of my issues. I can set speeds for through and diverging turnouts as you suggest and set speeds for blocks.? ?If I understand correctly, JMRI uses some formula of these two? along with pre-set speeds for signal aspects? in the file "signalspeeds.xml" to determine some speed value displayed when editing logic in? signal mast? pairs. Presumably I can edit and copy this file and change it's location to user preferences.? I'm not sure how warrants and dispatcher integrate or share speed data and tables. I haven't got as far as Warrants yet. Perhaps this will make things clearer but I haven't created a control panel yet. Do I need to do this first?? I can also, of course, set speeds in the decoder chip CVs. Does this overrule or work in conjunction with JMRI speeds (How do I make the decoder programmers work from within PanelPro?) Are there any further methods of setting auto train speed?? Thanks for reading? I'll keep trying. Please anyone chip in with other suggestions. StevLomax Steve 009 in UK |
Locked
Re: JMRI and NCE
¿ªÔÆÌåÓýHello Marc, ? I found the System Console Log. I have attached it below. I now have only one NCE connection now. ? Ken Skopp ? From: [email protected] <[email protected]> On Behalf Of forfoum@... ? On Mon, Jul 22, 2019 at 04:04 PM, Kenneth Skopp wrote:
Do you have a good reason to have a second NCE connection ?? You believe you deleted NCE2(N2).?? Clearly it was not deleted as per this message. 2019-07-23 05:59:00,298 util.Log4JUtil??????????????????????? INFO? - * JMRI log ** [main] 2019-07-23 05:59:00,327 util.Log4JUtil??????????????????????? INFO? - This log is appended to file: C:\Users\Ken\JMRI\log\messages.log [main] 2019-07-23 05:59:00,327 util.Log4JUtil??????????????????????? INFO? - This log is stored in file: C:\Users\Ken\JMRI\log\session.log [main] 2019-07-23 05:59:00,327 apps.AppsBase???????????????????????? INFO? - DecoderPro version 4.16+R6f9aced starts under Java 1.8.0_181 on Windows 10 x86 v10.0 at Tue Jul 23 05:59:00 EDT 2019 [main] 2019-07-23 05:59:00,528 gui3.Apps3??????????????????????????? INFO? - Starting with profile My_JMRI_Railroad.3f3718c5 [main] 2019-07-23 05:59:00,809 node.NodeIdentity???????????????????? INFO ?- Using jmri-kyUuSdgurhNiaayakslegv-3f3718c5 as the JMRI storage identity for profile id 3f3718c5 [AWT-EventQueue-0] 2019-07-23 05:59:00,903 xml.AbstractSerialConnectionConfigXml INFO? - Starting to connect for "NCE" [main] 2019-07-23 05:59:01,278 usbdriver.UsbDriverAdapter??????????? ERROR - Serial port COM4 not found [main] 2019-07-23 05:59:01,278 jmrix.ConnectionConfigManager???????? ERROR - Unable to create jmri.jmrix.nce.usbdriver.configurexml.ConnectionConfigXml for [Element: <connection/>], load returned false [main] 2019-07-23 05:59:01,278 plementation.JmriConfigurationManager ERROR - Exception initializing jmri.jmrix.ConnectionConfigManager: Unable to create several of your connections. [main] 2019-07-23 05:59:01,987 jmri.InstanceManager?????????? ???????ERROR - Should not set default of type jmri.CommandStation to null value [main] 2019-07-23 05:59:01,987 managers.ManagerDefaultSelector?????? WARN? - SystemConnectionMemo for NCE (class jmri.jmrix.nce.NceSystemConnectionMemo) provides a null interface jmri.CommandStation instance [main] 2019-07-23 05:59:01,987 plementation.JmriConfigurationManager ERROR - Exception initializing jmri.managers.ManagerDefaultSelector: System connection NCE provides a null manager for interface jmri.CommandStation [main] 2019-07-23 05:59:02,096 plementation.JmriConfigurationManager ERROR - Exception initializing apps.StartupActionsManager: jmri.util.prefs.InitializationException: Unable to run startup actions due to earlier failures. [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path program: is C:\Program Files (x86)\JMRI\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path preference: is C:\Users\Ken\JMRI\My_JMRI_Railroad\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path profile: is C:\Users\Ken\JMRI\My_JMRI_Railroad\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path settings: is C:\Users\Ken\JMRI\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path home: is C:\Users\Ken\ [main] 2019-07-23 05:59:04,939 util.FileUtilSupport????????????????? INFO? - File path scripts: is C:\Users\Ken\JMRI\My_JMRI_Railroad\ [main] 2019-07-23 05:59:05,770 throttle.PowerManagerButton?????????? INFO? - No power manager instance found, panel not active [main]
|
Hi,
Are you sure that your servo is compatible with DCC++? A standard RC servo requires a pulse width modulated signal, which the arduino servo library will generate, if that's what you have used in your test sketch. ?I'm possibly wrong here but I suspect the DCC++ code just puts out a logic high or low depending on the turnout setting, which won't drive a standard RC servo. Regards Paul |
Locked
DP feature request
Is it possible to add a column/field on the roster sheet for a consist address and have DP fill it in if the loco has a consist address. Thanks.
Jim K |