hello Steve,

First of all thanks for your hard work. I downloaded your early January 2019 version. I'm having a Lenz LZV100 and normally use my Lenz 23150 Li-USB to connect with a WIN10 to my central station. That works. But now I would like to switch to the RPI approach.
What doesn't work for me is the Auto Identify of the Lenz LIUSB (23150, not the newer 23151). I looked in your script whereyou grep the lsusb output. My Lenz LIUSB is recognized as "Bus 001 Device 005: ID 1111:1234 Pandora International Ltd." I modified the SH script to start the right profile. That works now but I now get the error message "Serial Port ttyACM0 not found". From where does JRMI get this ttyACM0 serial port config ? I only have a ttyS0 and ttyAMA0 available but none of them are talking with the Lenz USB interface.

Looking in /var/log/messages I found:

Jan 13 11:58:00 RPi-JMRI kernel: [? ? 2.191535] usb 1-1.1.3: new full-speed USB device number 5 using dwc_otg
Jan 13 11:58:00 RPi-JMRI kernel: [? ? 2.335924] i2c /dev entries driver
Jan 13 11:58:00 RPi-JMRI kernel: [? ? 2.338990] usb 1-1.1.3: New USB device found, idVendor=1111, idProduct=1234
Jan 13 11:58:00 RPi-JMRI kernel: [? ? 2.339006] usb 1-1.1.3: New USB device strings: Mfr=1, Product=2, SerialNumber=0
Jan 13 11:58:00 RPi-JMRI kernel: [? ? 2.339015] usb 1-1.1.3: Product: LI USB
Jan 13 11:58:00 RPi-JMRI kernel: [? ? 2.339027] usb 1-1.1.3: Manufacturer: Lenz

Jan 13 12:43:16 RPi-JMRI kernel: [ 2713.359458] usb 1-1.1.3: USB disconnect, device number 5
Jan 13 12:43:19 RPi-JMRI kernel: [ 2716.216244] usb 1-1.1.3: new full-speed USB device number 9 using dwc_otg
Jan 13 12:43:19 RPi-JMRI kernel: [ 2716.364524] usb 1-1.1.3: New USB device found, idVendor=1111, idProduct=1234
Jan 13 12:43:19 RPi-JMRI kernel: [ 2716.364532] usb 1-1.1.3: New USB device strings: Mfr=1, Product=2, SerialNumber=0
Jan 13 12:43:19 RPi-JMRI kernel: [ 2716.364538] usb 1-1.1.3: Product: LI USB
Jan 13 12:43:19 RPi-JMRI kernel: [ 2716.364541] usb 1-1.1.3: Manufacturer: Lenz
Jan 13 12:43:19 RPi-JMRI mtp-probe: checking bus 1, device 9: "/sys/devices/platform/soc/3f980000.usb/usb1/1-1/1-1.1/1-1.1.3"
Jan 13 12:43:19 RPi-JMRI mtp-probe: bus: 1, device: 9 was not an MTP device
?
The device is recognized but seems not be mapped to anything in /dev

Any clues how to solve this ? I assume, first by adding a new udev rule.

regards, Bruno (JMRI user from Belgium)


Locked Re: Cannot read, but can write, with Decoder Pro

 

Cant seem to edit the last post and both links go to the same image - if you scroll back you can see the default preferences also

/g/jmriusers/photo/81943/1?p=Name,,iain,20,1,0,0

Might be the right link?


Locked Re: Cannot read, but can write, with Decoder Pro

 

Thanks for the reply and suggestion.

I have checked that and everything says that it is set for the Z21 :(

I have placed 2 screenshots in an album for you to see

Defaults

Main Screen

Any other ideas?

Iain


Locked Re: Cannot read, but can write, with Decoder Pro

 

Check the Preferences, Defaults? if they are all on Z21 and not on Internal or some other option.

I do not own a ROCO system but I played around with PREFERENCES and can replicate the issue (greyed out buttons) and correct them in DEFAULTS.

Marc


Locked Re: Operations Pro Roster

 

Not sure if this page helps.


--
Peter Ulvestad

JMRI Users Group Moderator - ( )
Tam Valley Group Moderator - ( )
Sprog-DCC Group Moderator - ( )
Edmonton Model Railroad Association -


Locked Re: Operations Pro Roster

 

Jerry,

Better off using the CSV file format.? One trick is to do a file export and you'll get a CSV file with all of the fields labelled for you.? Enter your data in the appropriate columns and then do an import to pull your data into the program.

Dan


Locked Re: Lights

 

Hi folks,

Just to clarify,
Variable light intensities are NOT available for MERG CBUS at present, the only valid intensity values are 1 and 0

I've got some notes ready to go if / when someone wants to pursue this on the MERG forum, however I've got no immediate use case and?
AFAIK there hasn't been a request to add a light specific or general purpose intensity scale event.

As Dave's found,?x.setState(ON)?should work just fine, along with the 0 and 1 setIntensity values,

Steve.


Locked Re: Turnouts (not) updating on Panel

 

Hi Tim,

If the turnout table is changing to the correct state when messaged from the CAB then that's good :-)

This sounds similar to?/g/jmriusers/topic/28956227#155651
( Changing the Turnout Control to Direct in LE ) ?

Steve


Locked Re: Laptop Suggestions

 

Thanks for all your suggestions:

I will explore some more of the suggested options in the future.
I purchased a new HP Laptop today for less than $400.00 it has all the options I was looking for. the OS is windows 10
I will be loading JMRI and some of my other software give it a test run.
A few of the programs I have been running on XP could no longer be updated. so this should allow me to get up to date on some other things as well.

Thanks again

Chuck
Brick NJ


Locked Operations Pro Roster

 

I read that you can develop the Operations Pro roster either as a space- or comma-separated vale file.? With all the categories that can be entered, how does the space-separated file distinguish between the categories?? I take it that in the CSV file, two commas in a row would act as a place-holder?

Jerry Michels
Amarillo Railroad Museum


Locked Re: Programming locos with Fleischmann Twin-Center sw ver. 2.000 and DecoderPro 4.14

 

Ok so I downgraded the Twin-Center to version 1.100 of the software, here are the results after some testing. The issue with the scrolling text when starting DecoderPro with track power off remained. Stopping it is still possible by toggling the power on/off switch. Running locomotives with the JMRI throttle works as expected.
Reading CVs from JMRI worked once! The relay clicked and after some reading DecoderPro came up with a list of possible detected decoders (some M?rklin and Trix models, which is ok since the locomotive I'm using for testing is equipped with a Minitrix 14 pin decoder). This is what appeared on the LocoNet window:

00:37:58.016: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] ?Byte Read in Paged Mode on Service Track: CV8.
00:37:58.066: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] ?Byte Read in Paged Mode on Service Track: CV8.
00:37:58.066: [B4 6F 01 25] ?LONG_ACK: The Slot Write command was accepted.
00:38:05.522: [E7 0E 7C 23 00 00 20 07 02 07 03 7F 7F 68] ?Programming Response: Read Byte in Paged Mode on Service Track Was Successful: CV8 value 131 (0x83, 10000011b).
00:38:05.550: [EF 0E 7C 23 00 00 00 00 00 06 00 7F 7F 47] ?Byte Read in Paged Mode on Service Track: CV7.
00:38:05.606: [EF 0E 7C 23 00 00 00 00 00 06 00 7F 7F 47] ?Byte Read in Paged Mode on Service Track: CV7.
00:38:05.614: [B4 6F 01 25] ?LONG_ACK: The Slot Write command was accepted.
00:38:07.402: [E7 0E 7C 23 00 00 20 07 00 06 03 7F 7F 6B] ?Programming Response: Read Byte in Paged Mode on Service Track Was Successful: CV7 value 3 (0x03, 00000011b).
00:38:08.058: [EF 0E 7C 23 00 00 00 00 00 1C 00 7F 7F 5D] ?Byte Read in Paged Mode on Service Track: CV29.
00:38:16.062: [EF 0E 7C 23 00 00 00 00 00 00 00 7F 7F 41] ?Byte Read in Paged Mode on Service Track: CV1.
00:38:24.083: [EF 0E 7C 23 00 00 00 00 00 10 00 7F 7F 51] ?Byte Read in Paged Mode on Service Track: CV17.
00:38:32.103: [EF 0E 7C 23 00 00 00 00 00 11 00 7F 7F 50] ?Byte Read in Paged Mode on Service Track: CV18.
00:38:32.166: [EF 0E 7C 23 00 00 00 00 00 11 00 7F 7F 50] ?Byte Read in Paged Mode on Service Track: CV18.
00:38:32.166: [B4 6F 01 25] ?LONG_ACK: The Slot Write command was accepted.
00:38:33.936: [E7 0E 7C 23 00 00 20 07 00 11 00 7F 7F 7F] ?Programming Response: Read Byte in Paged Mode on Service Track Was Successful: CV18 value 0 (0x00, 00000000b).
00:38:33.965: [EF 0E 7C 23 00 00 00 00 00 12 00 7F 7F 53] ?Byte Read in Paged Mode on Service Track: CV19.
00:38:51.961: [83 7C] ?Set Global (Track) Power to 'ON'.
00:38:51.985: [83 7C] ?Set Global (Track) Power to 'ON'.

I noticed that the programming track was never turned off at the end of the reading though, unless I turned it off manually by resetting the command station. Sadly this was only a one-time success since I couldn't manage to make it work anymore; all the other times I tried reading I got the same timeout error and the same output on the LocoNet window:

00:46:30.286: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] ?Byte Read in Paged Mode on Service Track: CV8.
00:46:38.302: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] ?Byte Read in Paged Mode on Service Track: CV8.
00:46:46.323: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] ?Byte Read in Paged Mode on Service Track: CV8.
00:47:04.318: [83 7C] ?Set Global (Track) Power to 'ON'.
00:47:04.337: [83 7C] ?Set Global (Track) Power to 'ON'.

Another time I got the click and it started reading but eventually it hanged again without completing, throwing the timeout error and giving this output on the Monitor:

00:52:14.545: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] ?Byte Read in Paged Mode on Service Track: CV8.
00:52:22.561: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] ?Byte Read in Paged Mode on Service Track: CV8.
00:52:22.618: [EF 0E 7C 23 00 00 00 00 00 07 00 7F 7F 46] ?Byte Read in Paged Mode on Service Track: CV8.
00:52:22.618: [81 7E] ?Master is busy.
00:52:22.629: [B4 6F 01 25] ?LONG_ACK: The Slot Write command was accepted.
00:52:30.063: [E7 0E 7C 23 00 00 20 07 02 07 03 7F 7F 68] ?Programming Response: Read Byte in Paged Mode on Service Track Was Successful: CV8 value 131 (0x83, 10000011b).
00:52:30.091: [EF 0E 7C 23 00 00 00 00 00 06 00 7F 7F 47] ?Byte Read in Paged Mode on Service Track: CV7.
00:52:38.112: [EF 0E 7C 23 00 00 00 00 00 06 00 7F 7F 47] ?Byte Read in Paged Mode on Service Track: CV7.
00:52:46.132: [EF 0E 7C 23 00 00 00 00 00 06 00 7F 7F 47] ?Byte Read in Paged Mode on Service Track: CV7.
00:53:04.128: [83 7C] ?Set Global (Track) Power to 'ON'.
00:53:04.149: [83 7C] ?Set Global (Track) Power to 'ON'.

I tried resetting the Twin-Center and restarting JMRI multiple times but it didn't work.
On the other hand, reading CVs from the TC's keypad of course works and the output on the LocoNet monitor seems unchanged (it still states "IB-COM/Intellibox II"):

00:57:24.859: [E5 07 01 49 42 41 56] ?Uhlenbrock IB-COM / Intellibox II Start Programming Track.
00:57:36.218: [ED 1F 01 49 42 71 72 01 00 00 70 00 00 00 00 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00 65] ?Read CV in Direct Byte Mode from PT for Uhlenbrock IB-COM / Intellibox - CV: 1.
00:57:36.218: [81 7E] ?Master is busy.
00:57:36.224: [B4 6F 01 25] ?LONG_ACK: The Slot Write command was accepted.
00:57:39.558: [E7 0E 7C 00 00 00 72 07 00 07 2C 7F 7F 34] ?Programming Response: Uhlenbrock IB-COM / Intellibox II Programming Read Was Successful: CV8 value 44 (0x2C, 00101100b).
00:57:50.101: [E5 07 01 49 42 40 57] ?Uhlenbrock IB-COM / Intellibox II Stop Programming Track.

This is all the information I could gather. I hope it helps.
Good night,
Marco


Locked Re: Laptop Suggestions

PennsyNut
 

As for IBM/Lenovo. Doesn't every computer manufacturer peek at us? Doesn't HP? Or Dell? How can anyone be sure.
Now, I own 2 Lenovo desk tops. Well, my wife owns one. Both have AMD. I also got a Dell laptop to use just for JMRI when I get around to it.
So, not having personal experience to share. Let me state. The Dell has INTEL and I suppose it's because it's a laptop, even plugged in, is slow. But I did manage to download JAVA on both my desktop and on the laptop. Downloading JMRI is ? The laptop got v4.12 but hasn't been used. The desktop got v4.15 and I tried DecoderPro with no layout and quite frankly, got so frustrated and confused, I feel like I best wait until a kind guru living near me can help. My point in writing is that using a laptop for JMRI is IMHO a great idea. You can have it set up in one room and when needed, move it to the layout - if it's in another room. Or such. As for capacity, that's a personal decision. Yes, Microsoft is grabbing huge amounts every update, but ? My Lenovo is over 5 yrs old with W 10 and I have had no problems with it. You want problems, go W ME or W Vista. When they stopped supporting XP, I decided to just keep up with the updates on W 10.
Now all this is meant to be helpful. In no way, do I intend to insult anyone.
Morgan Bilbo, PRR fan


Locked Turnouts (not) updating on Panel

 

Hi,

Not sure if this is a stupid question or not, but I have a MERG CBUS system, I have a panel set up that can throw / close turnouts. When i use the CAB to change the point (using Short Addressing) the point changes, the turnouts table "State" changes but the point does not show the updated position / change.

Is there a way to get the Panel to update the position of the turnout, when the turnout is changed outside of JMRI?? (when manually clicking on the state button in the turnout table, this does update the panel)

Any pointers would be greatly appreciated.
Cheers
Tim


Locked Re: Blocks not working properly

 

Alberto,

Sounds like the sensors in the sensor table are not matching the BDL and the
LT5 indication. So if you only have one thing on the track (loco) and it is
moving, do you get a change in the sensor table (click on the column header
for active/inactive, it will sort them so any active move up) by seeing a
sensor change to active when it enters and leaves the block?

Next trick is to open the LocoNet->LocoNet Monitor, it will show the
traffic. To simplify things, slide the loco between two blocks, this should
give messages of a sensor going active and inactive. Let's use this to
figure out which sensor should be changing.

-Ken Cameron, Member JMRI Dev Team
www.jmri.org
www.fingerlakeslivesteamers.org
www.cnymod.com
www.syracusemodelrr.org


Locked Re: JMRI RailDriver In Cab Video #raildriver

 

¿ªÔÆÌåÓý

Thanks

?

Jay Beckham

?

Building a large O Scale layout in Berkeley Springs, WV.

?

Our Yahoo Group: Join: jaysoscalelayout-subscribe@... (The model railroad)

?

View my Blogs:

?

83 Pounds and Counting!

?

?

?

?

?

?

?


Locked Re: JMRI RailDriver In Cab Video #raildriver

 

There are two RailDriver items in the "Debug" menu: "RailDriver (built in)" and "RailDriver". The 2nd one is the original¡­ it doesn't work with macOS; the 1st one doesn't want to work with Windows. Try ether on Linux.


Locked Re: Throttle operating in reverse

 

Norb,

On 13 Jan 2019, at 7:58 AM, Norb Schertzer via Groups.Io <schertn@...> wrote:

I'm currently operating 5 engines on my railroad using JMRI 4.14, NCE SB5 USB interface v 7 and lastest java release. Added a new engine, but for some reason the JMRI throttle doen't work as expected. When I select forward the train actually goes in reverse and visa versa. The other 5 engineer behave properly ..throttle selection forward - train goes forward.
Do you have an NCE throttle (Power/Pro Cab, Cab04/5/6) you can connect to the SB5?

If so, do you see the same behaviour with the NCE throttle?
--
Dave in Australia


Locked Throttle operating in reverse

 

Hi All, before changing motor wires find out how the real railroad ran their Diesels. For instance I have a Milwaukee Road SD 7 which came from Proto 2000 wired to run long hood forward which is how the railroad ran it.

Al Babinsky


Sent from Xfinity Connect Application


Locked Re: Blocks not working properly

 

¿ªÔÆÌåÓý

No joy Ken all that happens is that it just switches around or stays active, I even tried playing around with the active inactive button, I basically have to manually turn active and inactive depending on what block it is in.

The only thing that works is assigning the block in the layout according to which block lights up, when the train is in the block that does not.

I don¡¯t know how that will work when I do my signal logics.

Sent from for Windows 10

?

From: Alberto Allen via Groups.Io
Sent: Saturday, January 12, 2019 2:10 PM
To: [email protected]
Subject: Re: [jmriusers] Blocks not working properly

?

Exactly Ken let me give it a shot, although I might had tried that and did not work, if I remember correctly

?

Sent from for Windows 10

?

From: Ken Cameron
Sent: Saturday, January 12, 2019 12:41 PM
To: [email protected]
Subject: Re: [jmriusers] Blocks not working properly

?

Alberto,

?

When looking at the sensor table, are you saying the sensors show the

opposite state, meaning active when there isn't a train and inactive when

there is? The cure for that is the 'Invert' checkbox, if checked, uncheck

it, if unchecked, check it. That will reverse the state.

?

-Ken Cameron, Member JMRI Dev Team

www.jmri.org

www.fingerlakeslivesteamers.org

www.cnymod.com

www.syracusemodelrr.org

?

?

?

?

?

?

?


Locked Re: Throttle operating in reverse

 

On Sat, Jan 12, 2019 at 03:58 PM, Norb Schertzer wrote:
I've even tried to reset the CVs to factory settings.. no dice. Other than reversed throttle direction, the engine behaves as it should. Any suggestions?
If you reset to factory defaults AND TESTED BEFORE ANY OTHER CV CHANGES ? and issue still present then the motor is wired wrong.
Invert connections to motor.

Marc