Real Snow,



The MRC interfaces to JMRI ok. One issue to consider with signaling is the
need to have:

1. Some way to detect where trains are on the tracks.

2. Some way to know which direction the turnouts are set.

3. Some way to control some of the turnouts remotely.

4. Some way to set the signals.



I don't think MRC has anything for #1 and I'm not sure of #2. They do
directly support #3 and #4. So you may find you have to mix some other types
of interfaces to cover all the needs. One example would be a LocoBuffer and
some of the many interface boards from RR-CirKits. JMRI is just fine mixing
many different systems for different uses so this would work with your MRC
controlling the trains. There are a number of other systems out there for
the rest of your signaling needs and you should check around to see what
provides your needs bet.



-Ken Cameron, Member JMRI Dev Team

www.jmri.org

www.fingerlakeslivesteamers.org

www.cnymod.com

www.syracusemodelrr.org


Locked Anyone usings MRC with JMRI?

 

Hello, I've had my MRC Prodigy Advanced 'squared' system for 8 years now and have been very happy with it. However I've only ever used the one base station and a single tethered controller. I got it because I like the controller and programing with it is easy as can be. I am starting a new larger layout and will be needing more than a single power district, and several controllers. I would also like to use JMRI to setup an automated signaling system along with block detection. I know MRC recently got a computer interface capability but will I be able to do all these things with an MRC system or will I just be constantly beating my head against the wall? I know a lot of people badmouth the MRC system but those same people have never used one before either.

My local group of model railroaders all seem to use Digitrax, and I sure it does everything i need and more but I don't like their controllers as well and I guess I like to be different, ha


Locked Re: macOS High Sierra

Jim Albanowski
 

Bob:

Not yet, the only test was a pair of USB to 232 and 485 standard dongles and they were happy with stock macOS... I need to relocate some pieces and parts to be sure all is well.

Jim


Locked Re: New versions.

 

On Jul 1, 2017, at 11:15 AM, boomer1944@... [jmriusers] <jmriusers@...> wrote:

I take it that the Operations portion of JMRI has reached maturity with no new updates the last couple of years.
Not sure what you¡¯re actually asking.

There are still lots of changes being made to the operations code. Here¡¯s a list of what Dan Boudreau has been doing, for example:



Is there something specific you¡¯re looking for?

Bob
--
Bob Jacobsen
rgj1927@...


Locked Re: New versions.

 

Operations continues to be upgraded and improved with every release.

Peter


Locked New versions.

 

I take it that the Operations portion of JMRI has reached maturity with no new updates the last couple of years.


Gordon Spalty


Locked Latest test version isues

 

Hi guys, I loaded the test version 4.7.6+R570b2bc with Java 1.8.0_131 (en_GB), on Windows 10 64bit Version 1703 OS Build 15063.413.


Much improved in various ways, especially drop-down lists of objects from the editor in Panel Pro.


I do however have some problems.


1. Signal Mast orientation is getting lost over restarts.
1.1 Also, the default orientation on a crossover seems arbitraryily set.
1.2 Also right clicking on the mast icon to bring up the menu sometimes (often) doesn't work unless you avoid the light and click the leg...
2. I am getting flashing green/red mast aspects on a cross-over. I realize that there may be a conflict in the logic. What I had hoped was that if I could choose a route by setting a signal to green manually, but when it flashes, it seems the logic is not 'active' properly, nor can I click on it to set it to an aspect. Is there a way round this? Is there a definite reason for the flashing??
3. Had a problem loading panels after maybe adding logix or something in a test panel, but then worked ok - my layout also wont load....
4. I am not sure if I am saving properly - when I quit out it tells me to save configuration data... but doesn't saving panels do this anyway?? What is the correct procedure for updating configuration data please??
I think some logic is getting lost over saves probably as I am not doing this right. I will look at this further...


This all may not be the case in older versions...


I am very happy to test further updates / provide my panels (test ones are more useful - the larger layout may give people headaches!)


John


Locked Re: Panel file won't load

 

Running 4.7.6. I read a suggestion in another post to run
TurnOffXmlValidation.py before loading the panel and that works. Panel
will now load without the error.

Here are the offending lines:

<signalhead
class="jmri.implementation.configurexml.SE8cSignalHeadXml"
systemName="IH:SE8C:"LT419";"LT420"" userName="LH82">
<systemName>IH:SE8C:"LT419";"LT420"</systemName>
<userName>LH82</userName>
<turnoutname defines="low">LT419</turnoutname>
<turnoutname defines="high">LT420</turnoutname>
</signalhead>

On 6/30/2017 11:14 AM, dave@... [jmriusers] wrote:
Ken,

What version of PanelPro are you running?

The easiest way to diagnose this problem is for you to upload the XML file to the ProblemsBeingWorkedOn folder.

Dave Sand

------------------------------------
Posted by: dave@...
------------------------------------


------------------------------------

Yahoo Groups Links




Locked Re: macOS High Sierra

 

On Jul 1, 2017, at 3:39 AM, jimalbanowski@... [jmriusers] <jmriusers@...> wrote:


The public beta of the newest Mac OS came up Thursday. My "spare" Mac is now up on it and initial JMRI start is good, more as I test.
Thank you!

Did you need to (re-)load any hardware drivers before it would see the layout?

Bob
--
Bob Jacobsen
rgj1927@...


Locked Re: JMRI will not load

 

Richard,



First thing is to look at the log file from starting JMRI. Since you aren't
getting a screen to interact with, you go to the files. Off the JMRI
directory under your username, ex c:&#92;Users&#92;Richard&#92;JMRI and then look for
the 'log' directory. The file session.log is the results of the last attempt
to start JMRI. You can read it with a simple text editor like Notepad. Doing
a cut/paste from that into a message for us would help.



The files message.log are a sequence of all your prior runs of JMRI. There
may be further clues in there, but the current session is the starting
point.



-Ken Cameron, Member JMRI Dev Team

www.jmri.org

www.fingerlakeslivesteamers.org

www.cnymod.com

www.syracusemodelrr.org


Locked Re: JMRI will not load

 

Hi.
I had a similar problem with my 64bit Windows 10 laptop. It was something
related to Java I suppose. Just open the task manager and look for services
that start with "jogamp"+a series of numbers. If they are there, try to
terminate them and the jurisdiction startup should resume. Hope it helps.

Roberto

Il 01 Lug 2017 01:13, "richard@... [jmriusers]" <
jmriusers@...> ha scritto:




Is anyone else having this issue? After installing 4.7.5, I see the Java
logo, and then the JMRI logo, but then nothing. No error messages, nothing.
It just goes away.


So I tried 4.7.6, but get the same result. Then I tried 4.6 production
with same result. Next, I uninstalled Java and JMRI, wiped out the
directories, and rebooted. Installed 4.6 again but still no launch.


I am running Windows 10 Pro on a 64 bit machine, and I have had numerous
successful prior versions on this machine for years.


Any ideas?


Thanks,


Richard





Locked Re: How to use division and csv modules within a JMRI script

 

Hi,


I found the answer to importing division and csv modules in to JMRI script:


Place:


from __future__ import division
import csv



as the first lines in the script.




Regards


Nick


Locked Problem getting anything to work - JMRI V4.6

 

I have not used JMRI for several months and the only chnage to my layout since its last use is the introduction of NCE EB1 circuit breaker. ?Since fitting the EB1, I have been able to operate everything with my Power/Pro Cab and SB3a booster but now find that I cannot operate anything through JMRI. ?JMRI loads properly; there are no error codes or messages in red; I can display the panel and the roster but cannot get either the throttles or the points to work. ?On screen, the points change but nothing happens on the layout - equally, the throttle functions highlight and the slider works but nothing moves. ?Can anyone iddentify the problem and tell me how to overcome it pleas?
Harold.

[Non-text portions of this message have been removed]


Locked macOS High Sierra

 

Group:


The public beta of the newest Mac OS came up Thursday. My "spare" Mac is now up on it and initial JMRI start is good, more as I test.


Jim Albanowski


Locked How to use division and csv modules within a JMRI script

 

Hi,


As part of some tests I'm doing on RFID tag reading at speed I'd like to use the division and csv functions in my JMRI script.


Does anyone know how to import/ turn on these modules?.


Also which version of Jython does JMRI 3.8 and 4.6 use?.




Regards


Nick


Locked Operations - print manifest

 

With these steps the train's manifest appears in preview.
>Operations?>trains>build>preview>
Is it possible to print this preview manifest to file? If so how is this
done please?
James (Gil) Oakes


[Non-text portions of this message have been removed]


Locked JMRI will not load

 

Is anyone else having this issue? After installing 4.7.5, I see the Java logo, and then the JMRI logo, but then nothing. No error messages, nothing. It just goes away.


So I tried 4.7.6, but get the same result. Then I tried 4.6 production with same result. Next, I uninstalled Java and JMRI, wiped out the directories, and rebooted. Installed 4.6 again but still no launch.


I am running Windows 10 Pro on a 64 bit machine, and I have had numerous successful prior versions on this machine for years.


Any ideas?


Thanks,


Richard


Locked Re: Consist Settings

 

If the bell on 5629 was ringing or its headlight was on prior to selecting CON 5203, you will not be able to turn either off using CON 5203. You will need to select CON 5629, turn them off and then reselect CON 5203.

You can only operate switches in the loco cab you currently occupy (the CON xxxx you currently have selected), same applies to a real loco.

If all locos need to respond to the command (e.g. Sound On, Mute, Brake) that is when you set that F key bit in CVs 21/22)
--
Dave in Australia

On 1 Jul 2017, at 10:39 AM, znrauiufnjz2e6tsduf24xoihjbzwl5y3fdj7ebx@... [jmriusers] <jmriusers@...> wrote:

Something strange, when I select CON 5203, and ring the bell, it only rings once then shuts off. Loco 5629's bell continues to ring.


Locked Re: Consist Settings

 

Have you Read Sheets to confirm the CV21&22 settings?
--
Dave in Australia

On 1 Jul 2017, at 10:39 AM, znrauiufnjz2e6tsduf24xoihjbzwl5y3fdj7ebx@... [jmriusers] <jmriusers@...> wrote:

Nothing changed. All fields for both locos in JMRI Consist Tab, are set to "Locomotive Address Only. Wrote the sheets to both locos. And CV's 21 - 24 are all set to "0".


Locked Re: Consist Settings

 

Silly question, what consist address are you using?
Jay-AT&SF