Operations manifest printing
#operationspro
JMRI
Panel Pro Version 4.14 +Rd060e0b JAVA Version 1.8.0_241(en) PRINTER Canon TS6120? -? Wireless Have searched the problem below with no results. Cannot print manifest when ¡°Preview¡± is unchecked. Run build ¨C press print ¨C print window comes up ¨C press properties ¨C check ¡°preview before printing¡± OK my way out and ¡°Canon Preview window¡± shows.?? The window shows the Manifest page. Press ¡°Start Printing¡±????? Window disappears and nothing happens, computer just sits there with no error messages. Note ¨C 1? -? ¡°Use text editor¡± is checked in Manifest print options. 2? -? Print Queue shows that the printer is online and that ¡°it is printing¡±. 3? -? I can print the manifest if I check ¡°show preview¡± then go to preview and print it from there. 4? -? I am able to print all other pages. This seems very strange that having preview unchecked is the only place that causes this problem. Also strange that no errors are appearing and the computer is just sitting doing nothing. Anyone have any ideas.? Irvin |
Locked
Re: Econami and Tsunami2 Programming issue
#nce
#soundtraxx
No, it doesn't. The bug in the firmware applies only to the Power Pro system. The heading in Dave's post specifically states: "Power Pro CV Limitations".Does any of this carry over to CV writing and reading with PowerCab system. I use my PowerCab for only Program Track and the Pro system in the layout <<<< Best regards, Steve Steve Haas Snoqualmie, WA |
¿ªÔÆÌåÓýtylergrote, Seems like this is a newly common problem, but I cannot figure out what I'm doing. Help is appreciated! COM3 port is confirmed at 9600 baud in device manager (Windows 10). Confirmed same settings in DecoderPro Preferences.? What matters is that the JMRI baud rate and the NCE USB Jumper settings match.
This tells us that JMRI has been able to communicate with the NCE USB and it has reported that it is a V7 and all jumpers are off. These are correct settings. Do not change them under any circumstances. If you do, you will just make troubleshooting extremely difficult.
You seem to have tried the Power button. The Power Cab does not support that command so JMRI has blocked it.
The communication takes place on wires 3 & 4 of the Cab Bus cable. So check your connectors sockets and cables, try the NCE USB in the other available socket (rear or front right. If you have any spare cables, try swapping out cables. Let us know what you find. Dave in Australia |
Locked
Re: Two trains on Main line
#automation
Okay might have part of my problem solved. Managed to get the trains moving and one even stopped where I think it should have. Still need to figure out how to stop them from running in each?other. Phil |
Bob, The big problem right now is that I DO NOT get the warnings when I load your panel. The main difference is that I have a new profile to setup the test. After you start JMR and get the warnings, go to Help >> System Console, click on Copy to clipboard and paste the results in a reply. After you have done that, I will have another request which will depend on the system console content. ?I hope to re-create your environment as closely as possible. Dave Sand ----- Original message ----- From: rzeollaorcl <robert.zeolla@...> Subject: Re: [jmriusers] New JMRI Version breaks my panels #4-18 Date: Friday, February 07, 2020 6:55 PM For instance,? in an earlier post you said "The "not compatible" error occurs when the neighboring blocks are not consistent between two panels.".? What does that mean?? Can you give me an example? I see on the Conemaugh Layout panel I use crossovers, but on the individual CP panels, it looks like I use left and right hand turnouts.? But this can't be causing the problem because its the same on crossovers that are not throwing the warning message. And let's not forget, I've been running this panel for a few years without any issue.? This problem just came up when I installed the new version last week. |
Locked
Re: New Decoder definition file
Bob Z,
On 8 Feb 2020, at 12:06 PM, rzeollaorcl <robert.zeolla@...> wrote:No, the latest ESU decoders (Essential Sound Unit and LokSound 5) require new Java code in JMRI. Your way forward is to upload your broken panel to a folder with your name in Files Being Worked On, explain your problem, attach a JMRI System Console log and get help to fix your panel. Dave in Australia |
Locked
New Decoder definition file
Hello,
I recently purchased a ScaleTrains Operator locomotive with the ESU Essential Sound Decoder in it.? Unfortunately, the version of JMRI I was running did not include this decoder definition.? I upgraded to the latest version and got the decoder definition in DecoderPro.? Great!? Well not really.? The upgraded version of JMRI broke my panel.? I'm tempted to restore the backup of JMRI so that my panel works again.? But if I do that, is there a way to get the new decoder definition into it? Thanks, Bob Z |
For instance,? in an earlier post you said "The "not compatible" error occurs when the neighboring blocks are not consistent between two panels.".? What does that mean?? Can you give me an example?
I see on the Conemaugh Layout panel I use crossovers, but on the individual CP panels, it looks like I use left and right hand turnouts.? But this can't be causing the problem because its the same on crossovers that are not throwing the warning message. And let's not forget, I've been running this panel for a few years without any issue.? This problem just came up when I installed the new version last week. |
Locked
Re: Two trains on Main line
#automation
I don¡¯t have any signals. I am just on a test train trying to get things working better installing on the main layout. I have been looking at the dispatch panel and can not see how to start the trains moving. Phil |
Locked
Re: Panel Editor - Signal Heads not able to be Dragged and Dropped from Palette
#paneleditor
Bob England
Thanks Cliff
I uploaded the revised panel.? And if I am correct, the only changes as you suggest were done to the XML file was?to the URL pointers.? For example: url="program:resources/icons/_RJE/Signals/SearchErrorFlash.gif" gets changed to: url="preference:resources/icons/Signals/SearchErrorFlash.gif" Am I correct?? If so, how did you do that?? I assume it was something other than manually adjusting the XML coding. You also moved the icon files to the user resource folder (?) I opened your file with your configuration (have never tried the loconet simulator before so it took a second to get oriented.? I tried to place a edit the "X" signalhead with no luck, and also tried to place a new signalhead, and it again only placed an "X" no matter which iconset was selected. I've placed a screenshot file at: /g/jmriusers/files/ProblemsBeingWorkedOn/RJE/200207%20-%20Screen%20Shot%20-%20Panel%20Editor%20-%20Coombe%20Junction.zip To show what I am seeing in case it might be different than what you see.? Note the "X" on the UPPER BRIDGEBURY part of the panel.? This is a signal head icon, placed using ADD ITEMS, that I can't change to a working icon set. In answer to your questions:
Thanks again. BobE |
Locked
Re: Setting Max Speed on Broadway Limited & Digitrax N Scale Decoders
Robert Diepenbrock
Dear Alan and Marc,
toggle quoted message
Show quoted text
Are they slower than expected?- YES Are they slower than another loco?- YES Are they slower than another identical loco?- YES, To be accurate the decoders in question are slower than identical decoders in identical or similar locos, with the same JMRI Speed Control settings. Are they slower than a loco with a different decoder/motor/gear train ... ?- YES EXAMPLE: Digitrax DN166I1C Decoder (Intermountain F3 & F7). A-B-A set of "Black Widow F7s"- F7A, F7B, F7A runs at acceptable speed. Digitrax DN166I2 Decoder (Intermountain FP7)& DN166I1C Decoder (Intermountain F3 & F7) A-B-A set of "Black Widow F7s"- F7PA, F7B, F7PA runs slower at unacceptable speed EXAMPLE: Broadway Limited E6s A-A Paragon (UP & ATSF) both these Paragon sets run at similar (slower speeds) than Broadway Limited PA1s, PA2s (Paragon) and E8s (Paragon 2). I realize this is a moving target with probably too many variables to determine exactly the cause of the slower running. In the case of the Broadway Limited E6s A-A Paragon (UP & ATSF) These drive trains are the same and act the same. Probably mechanisms, rather than decoder. In the case of the Digitrax F7s & FP7s These drive trains are the same but act differently. Maybe mechanisms. I've had luck disassembling Intermountain F units and cleaning the factory installed grease out of the drive gears, which raises speed. I'm going to do this with these Intermountain units to see if it solves the slow running. In the case of the Broadway Limited units, I'm not sure of a solution. This may just we the way these older Paragon units were made. Regards, Robert Diepenbrock On 2/7/20 9:20 AM, Alan Pearce via Groups.Io wrote:
3-point speed table or the 28-point speed table can not make an engine go faster.Yeah, but he didn't say at any stage what they are slower than. |
Locked
Re: Two trains on Main line
#automation
If dispatcher is running the trains, it will (attempt) to obey signals. If it's not Dispatcher, then jmri can only set the signals to stop, but not force anything to stop at them. On Fri, Feb 7, 2020 at 7:28 PM Phil Law <tlcphil@...> wrote:
|
Locked
Re: Panel Editor - Signal Heads not able to be Dragged and Dropped from Palette
#paneleditor
Bob, A test config profile built from your original upload is now located at /g/jmriusers/files/ProblemsBeingWorkedOn/RJE/Bob_England_CA1.jmri.zip The folder has been stripped down to as close to minimal as I can safely execute using the LocoNet Simulator, but with the exception that a log subfolder is included with the zipped folder. The log of my most recent execution is there, just in case you are curious. Other than the heavy handed moving the resources folder structure, only the renamed "BOBsControlPanel 10r CA1.xml" file has been edited. Even so, I have attempted to ONLY edit the url descriptions to point to your icons. Perhaps I should have worked with the "Test01.xml" file instead? In case you are not familiar with the "Add Existing..." option provided with config profile usage, try what is documented at but you may still be in unfamiliar territory. That document is a little sketchy about the features you will need. It should be noted, that my style of using the config profiles evolved when the concept of profiles was still being developed and there is likely to be lots of different opinions as to what I should have done better in the uploaded config profile. As outlined in the files/ProblemsBeingWorkedOn/RJE/ description several questions now remain before progress can be made:
When you can confirm that I finally have a clean working copy of what you see on your computer, then I will also need further information. It is now abundantly clear that my attempts to duplicate your symptoms was done while working with a very simple panel that only had about ten blocks and maybe twenty signals. The fact that you have developed a very complex set of panels and only recently experienced a problem casts a completely different perspective on this discussion. Cliff in Baja SoCal |
Locked
Two trains on Main line
#automation
I am a new user of JMRI running 4.1 with a Digitrax DSC51 , SE8, two - four train detector, and a laptop running windows 10. I am trying to create blocking to prevent two trains from running into each other. Being a test track I have not created the graphic control panel, planning to do that later. Plus I have not been able to accomplish creating the background of the control panel. I have managed to create block, sensor, portal and transit tables. The trains will change the block colours as they travel around the loop. However they continue to run into each other. I have open a script the allowed me to open the Operation and Dispatcher panels not sure if was the right one or not. I would appreciate any assistance?you can provide. Phi |
Seems like this is a newly common problem, but I cannot figure out what I'm doing. Help is appreciated!
I just got back into model railroading. I purchased a NCE PowerCab starter set along with a NCE USB Interface. I'm trying to set Loco roster and some CV settings with JMRI. Took items out of package and plugged in per instructions. Downloaded JMRI after USB Driver was installed.? COM3 port is confirmed at 9600 baud in device manager (Windows 10). Confirmed same settings in DecoderPro Preferences.? Service Mode Programmer NCE Is Online. Operations Mode Programmer NCE Is Online.? Every time I try to communicate with PowerCab from computer/JMRI via the identify function,? I time out and nothing occurs.? It also says "Unknown Programming Mode" at the top of the screen.? 2020-02-06 23:13:29,893 util.Log4JUtil? ? ? ? ? ? ? ? ? ? ? ? INFO? - * JMRI log ** [main]
2020-02-06 23:13:29,901 util.Log4JUtil? ? ? ? ? ? ? ? ? ? ? ? INFO? - This log is appended to file: C:\Users\tyler\JMRI\log\messages.log [main]
2020-02-06 23:13:29,901 util.Log4JUtil? ? ? ? ? ? ? ? ? ? ? ? INFO? - This log is stored in file: C:\Users\tyler\JMRI\log\session.log [main]
2020-02-06 23:13:29,905 apps.AppsBase? ? ? ? ? ? ? ? ? ? ? ? ?INFO? - DecoderPro version 4.18+R37ad3d0 starts under Java 1.8.0_241 on Windows 10 x86 v10.0 at Thu Feb 06 23:13:29 CST 2020 [main]
2020-02-06 23:13:30,041 gui3.Apps3? ? ? ? ? ? ? ? ? ? ? ? ? ? INFO? - Starting with profile My_JMRI_Railroad.3e2624fc [main]
2020-02-06 23:13:30,164 node.NodeIdentity? ? ? ? ? ? ? ? ? ? ?INFO? - Using 97c2d6e1-b0b9-4e73-bad0-4c798080bcc3 as the JMRI storage identity for profile id 3e2624fc [AWT-EventQueue-0]
2020-02-06 23:13:30,257 xml.AbstractSerialConnectionConfigXml INFO? - Starting to connect for "NCE" [main]
2020-02-06 23:13:30,530 usbdriver.UsbDriverAdapter? ? ? ? ? ? INFO? - NCE USB COM3? port opened at 9600 baud [main]
2020-02-06 23:13:30,639 nce.NceConnectionStatus? ? ? ? ? ? ? ?INFO? - NCE EPROM revision = 7.3.0 [AWT-EventQueue-0]
2020-02-06 23:13:30,690 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path program: is C:\Program Files (x86)\JMRI\ [main]
2020-02-06 23:13:30,690 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path preference: is C:\Users\tyler\JMRI\My_JMRI_Railroad.jmri\ [main]
2020-02-06 23:13:30,690 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path profile: is C:\Users\tyler\JMRI\My_JMRI_Railroad.jmri\ [main]
2020-02-06 23:13:30,691 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path settings: is C:\Users\tyler\JMRI\ [main]
2020-02-06 23:13:30,691 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path home: is C:\Users\tyler\ [main]
2020-02-06 23:13:30,691 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path scripts: is C:\Program Files (x86)\JMRI\jython\ [main]
2020-02-06 23:15:03,285 nce.NceMessage? ? ? ? ? ? ? ? ? ? ? ? ERROR - attempt to send unsupported binary command KILL_MAIN_CMD to NCE USB [AWT-EventQueue-0]
2020-02-06 23:15:04,765 nce.NceMessage? ? ? ? ? ? ? ? ? ? ? ? ERROR - attempt to send unsupported binary command KILL_MAIN_CMD to NCE USB [AWT-EventQueue-0]
2020-02-06 23:15:21,693 jmrix.AbstractMRTrafficController? ? ?WARN? - Timeout on reply to message: A9 00 1D consecutive timeouts = 0 in nce.NceTrafficController [nce.NceTrafficController Transmit thread]
2020-02-06 23:15:23,951 jmrix.AbstractMRTrafficController? ? ?WARN? - timeout flushes receive buffer: 30 [nce.NceTrafficController Receive thread]
?
?
|
Locked
Re: Panel Editor - Signal Heads not able to be Dragged and Dropped from Palette
#paneleditor
Bob, I don't have any insight yet into the signal head issues. ?However, I recommend that custom components reside within the "user files location". This help page has a complete explanation of JMRI file structures: As indicated in the help page, the keyword for the user files location is "preference:". ?If you look at your xml files, you will see that you currently have your custom icons at "program:resources/icons/_RJE...". Since your zip file included the Wilbury_Spa profile, I am able to determine your some of your configuration. The profile.properties file has lots of information including some of the file location definitions:
The jython location is a default value, the user files location was set using "Preferences >> File Locations" and the roster location was set using Preferences >> Roster. ?I also set jython to be part of the user files location.? It appears that the custom icons are currently in their own J location. ?To facilitate automatic JMRI overrides they need to move to resources/icons within the user files J location. When you build image indexes you have a choice of Program Directory or Preferences Directory. ?Things selected from the program directory get the "program:" key while things selected from the preferences directory get the "preference:" key. The similar process works for icon sets. While migration is a one time event, it is a lot of work.
Make sure you have good backups. Dave Sand ----- Original message ----- From: Bob England <rje.bob@...> Subject: Re: [jmriusers] Panel Editor - Signal Heads not able to be Dragged and Dropped from Palette #paneleditor Date: Friday, February 07, 2020 7:59 AM Thanks Cliff ? I stored the files in the zip file under the same folder/sub-folders as they are under on my J: drive (where I keep copies of all my user modified files).? These same files are in the JMRI program directory on C:\Program Files (x86)\JMRI and in the C:\Uers\RJE\JMRI folder (note this is a Windows7 machine) ¨C all in the same folders.? I keep all altered files on my J: drive so I can back them up easily.? The custom icons (including panels icons I create in AutoCAD¨¤PDF¨¤JPG) that you see are manually copied to the appropriate icons subfolder in C:\Program Files (x86)\JMRI (under Resources I think(?) ¨C I¡¯m not at my layout computer at present) as I have no idea how to point to the J: drive to find these files. ? The scripts I have are to monitor the power setting and push its status into a sensor, to listen to my PM42 inputs, and to set my turnouts ¡°CLOSED¡± at start-up.? These are basically slight modifications to the canned scripts that come with JMRI.? The fourth script was my first attempt at writing my own script from scratch, and is intended to provide an interface between JMRI and a Walthers turntable I have ¨C it does not work properly.? I can send you copies of the script files if you think it would be helpful. ? All 4 Panel Editor files and the Layout Editor file automatically load when the program fires up; I don¡¯t have to load any manually.? I could not tell you which order they load in as JMRI loads the files.? I don¡¯t think it matters, as I created a new layout called ¡°TEST¡± and created a panel in it, and it exhibits the same difficulties as ¡°WILBURY SPA¡±. ? Sorry, I misunderstood your thought on ¡°copying mechanism¡±; I read ¡°coping¡± mechanism and thought it to be a special work-around process.? Yes, I do the copying mechanism thing you mention for all my user files, putting them in the three places noted above.? You mention that ¡°it is much safer to provide the start-up and file default portions of the Config Profile to consistently point to your locally modified files¡± ¨C do I do this by changing the default search location under ¡°Configuration¡± tab of ¡°Preferences¡±?? I tried this last night but it changed nothing, but I left the original JMRI program file folder on the list (with the box un-ticked). ? I hope this helps.? ? I¡¯d be interested in your thought on the error message I get when trying to change one of the bad signals to a different icon set: ? ¡°2020-02-05 19:09:54,619 ptionhandler.UncaughtExceptionHandler ERROR - Uncaught Exception caught by jmri.util.exceptionhandler.UncaughtExceptionHandler [AWT-EventQueue-0] ? I can¡¯t help but thinking this might point us in the right direction. ? Thanks for looking at this for me Cliff ! ? BobE ? From: [email protected] [mailto:[email protected]] On Behalf Of Cliff Anderson ? Bob, There is now a copy of your zip file on my computer, but I am having some difficulties unraveling how the files fit together. It appears from your file named "200206 - RJE - JMRI Files for Debugging\200206 - RJE - JMRI Files for Debugging\DRIVE J\RJE User Files\Wilbury_Spa\profile\profile.xml" that you execute several scripts during the startup process, but evidently load one or more of your panels manually after the startup process has completed. Or maybe one or more of those scripts load panel files. Please explain what is wrong with my summary. For the forensics activities, it is important for me to understand which panel file should be loaded or if multiple panel files are loaded, which order do you follow.
It is not likely that your signal icons problems are due to what you describe here, but the process does seem to allow for some ambiguity as to which of your versions might get left out or overwritten. Extra caution would be in order here.
There are numerous message threads on this groups messages record, but essentially the writers describe some kind of method for copying the folders with locally modified resources back into the "program:" folder. Some do it manually and some have developed elaborate batch or script files. It may take extra effort, but it is much safer to provide the startup and file default portions of the Config Profile to consistently point to your locally modified files.
It is entirely likely that we are looking at a symptom that is being caused by several small errors, rather than some big problem. Cliff |
Locked
Re: Setting Max Speed on Broadway Limited & Digitrax N Scale Decoders
3-point speed table or the 28-point speed table can not make an engine go faster.Yeah, but he didn't say at any stage what they are slower than. Are they slower than expected? Are they slower than another loco? Are they slower than another identical loco? Are they slower than a loco with a different decoder/motor/gear train ... ? we are attempting to guide a fix on an ill-defined problem. On Fri, 7 Feb 2020 at 05:16, <forfoum@...> wrote:
|