Locked
Re: DCS240 JMRI
Further to Mick's point number 4: " If you get a 302 programmer busy error that won't go away (the DCS240 programmer is prone to crashing), just power off the DCS240, wait 15 seconds and power on
By
billybob experimenter
·
#139204
·
|
Locked
Re: Consist lights, CV21 and CV22 values. Reminder please.
While the NMRA standards define the bit mappings of CVs 21 & 22, various manufacturers have modified and extended these, so you need to rely on the Consist pane for each roster entry. The overall
By
Dave Heap
·
#139203
·
|
Locked
Consist lights, CV21 and CV22 values. Reminder please.
Hi All, Just need a reminder for CV setting for intermediate units within a consist. I know I have it somewhere, just can't find it! Many thanks, Mike.
By
MICHAEL PAYNE
·
#139202
·
|
Locked
Re: DCS240 JMRI
Having had a lot of trouble myself with a DCS240, and long chains of discussions here and with Digitrax, I'd suggest to you from bitter experience: 1. Ensure that the DCS240 is at the latest firmware
By
Mick Moignard
·
#139200
·
|
Locked
Re: Test version 4.9.2 problems under Windows 7
Hi Bob Some more info about what I've done using current 4.9.2: After removing the previous decoderindex.xml from my user's folder (created with 4.9.1 when I updated the Zimo V36 Plus profile), and
By
alain c
·
#139199
·
|
Locked
Re: 'signalHeadManagerInstance' not found in 4.9.2?
Bob: I don't see where I have made any script references to jmridefaults.py, but renaming jmri_bindings.py to that name resolved my issue. Thank you (again). I had to change some script references to
By
randomburnout@...
·
#139198
·
|
Locked
Re: Having trouble starting DP with Sprog2v3
You need to go to Preferences->Connections and select a valid serial port from those available. The valid name for a SPROG connection will be something like cu.usbmodemxxxx (not the tty.usbmodemxxxx).
By
Dave Heap
·
#139201
·
|
Locked
Re: Test version 4.9.2 problems under Windows 7
Bob, I installed 4.9.2 again. Then I checked for the decoderindex.xml file and I did have that file under My_JMRI_Railroad. I moved it out of there then launched DecoderPro. I put it through lots of
By
5i5kb4wwnc2tul2puyiz46rnzqoc733wbkjzio4p@...
·
#139197
·
|
Locked
Re: Test version 4.9.2 problems under Windows 7
Might be more than one problem. Could you try the #1765 (or later) installer from http://jmri.tagadab.com/jenkins/job/Development/job/Packages/ please? It¡¯s building now, should be done in about 20
By
Bob Jacobsen
·
#139196
·
|
Locked
Re: DCS240 JMRI
Will look tomorrow when I get to club Sent from Yahoo Mail on Android
By
ronmerrill69
·
#139195
·
|
Locked
Re: DCS240 JMRI
User with problems with a DCS240 and a locobuffer. I would like to know what the version number of the loco buffer is.. Its the first number when you select Loconet>LoconetStats. Walt
By
walter.stanley.thompson.3@...
·
#139194
·
|
Locked
Re: 'signalHeadManagerInstance' not found in 4.9.2?
If you have scripts referring to ¡°jmridefaults.py¡±, please replace that with a reference to ¡°jmri_bindings.py¡±. Or you could copy the ¡°jmri_bindings.py¡± file to be named
By
Bob Jacobsen
·
#139193
·
|
Locked
Re: DCS240 JMRI
My programing track is less than 3ft away. We upgrade from a dcs 200. But we also have 5 sections each control 30 ft at max. My DCS240 is the main and controls antennas, programing track, and a 2
By
ronmerrill69
·
#139192
·
|
Locked
Re: DCS240 JMRI
I would like to add some interesting observations here, I also hooked up a new dcs240 from a dcs 100. Initially I had a 30 ft run from the command station on 12 gauge running to a dcc specialties
By
Tristan Dwyer
·
#139191
·
|
Locked
Re: DCS240 JMRI
I'm running 4.8..,
By
Richard Neibert
·
#139206
·
|
Locked
Re: DCS240 JMRI
I get that error when the PR3 is in the wrong mode on my home set up with a DCS200. Our club uses the 240 just for running the layout so we haven't run in to this with it. So not sure how to change
By
David Klemm
·
#139190
·
|
Locked
Re: DCS240 JMRI
Did you do the update v.3 on the DCs240? [Non-text portions of this message have been removed]
By
Richard Neibert
·
#139189
·
|
Locked
Re: DCS240 JMRI
Will need to get back with you, but I installed newest version that was not a test version, I think 4.8 production release Sent from Yahoo Mail on Android On Mon, Aug 14, 2017 at 9:28 PM, DAVID KLEMM
By
ronmerrill69
·
#139188
·
|
Locked
'signalHeadManagerInstance' not found in 4.9.2?
Upgraded from 4.9.1 to 4.9.2 and now it does not like this line from jmridefaults.py and stops dead before showing any of my Layout Editor Panels. Any thoughts? 2017-08-14 21:18:35,692
By
randomburnout@...
·
#139187
·
|
Locked
Re: DCS240 JMRI
What version of JMRI are you running? The 240 was addressed around 4.7.2. David Klemm Sent from my iPhone 7 Plus ________________________________ Sent: Monday, August 14, 2017 7:12:32 PM To:
By
David Klemm
·
#139186
·
|