¿ªÔÆÌåÓý

Date
Locked Re: JMRI Startup Errors in Eclipse
It looks like somehow the steps that create the ¡°version¡± code aren¡¯t being run. When you tell Ant to do the build, the ¡°update-template-code¡± step handles that. Do you have Eclipse
By Bob Jacobsen · #138793 ·
Locked Decoder Pro output for Team Digital BLOC8D
I am working on an installation of Team Digital BLOC8D for our club and would like some help on the readout I get when monitoring the LocoNet via Decoder Pro. This is the sequence I get when using the
By Jerry Michels · #138792 ·
Locked Re: Locobuffer locking up from data overload?
Ah, I must have missed that. Thanks! Sincerely, Steve
By Steve · #138791 ·
Locked Re: Trouble with Virtual Signals
Bob Z, One clue if you do use SSL is that to combine turnouts, you need to create virtual signals and then make the real one 'distant' to the virtual so it combines the logic results. When 'distant'
By Ken Cameron · #138790 ·
Locked Re: JMRI Startup Errors in Eclipse
I'm also Win10, Eclipse Oxygen 4.7.0, and doing fine with HEAD. I can run or debug just fine and not getting similar errors. -Ken Cameron, Member JMRI Dev Team www.jmri.org
By Ken Cameron · #138789 ·
Locked JMRI Startup Errors in Eclipse
I have a JMRI git repository on my Win 10 system. in Eclipse Mars 2, 4.7.1, 4.8 and 4.9.1 build correctly. 4.7.1 runs fine from Eclipse including Locobuf and CMRI interfaces. However, I get the
By saverinm@... · #138788 ·
Locked Re: Crossing in layout editor
The large majority of locos have all the wheels on each side directly electrically connected. So I am not sure how the frog voltage could ever be different from the track voltage? Andy
By Andy Reichert · #138787 ·
Locked New file uploaded to jmriusers
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the jmriusers group. File : /Bob Z Virtual Signals/SignalLogicKiskiiWest2.png Uploaded by
By jmriusers@... · #138786 ·
Locked Re: Trouble with Virtual Signals
Bob Z, Check out my web page http://quaker-valley.com/CTC/QV_CTCnew.html about mid way down is a picture of the layout editor panel with all of the intermediate internal signals revealed. I used SSL
By rbucklew · #138797 ·
Locked Re: Trouble with Virtual Signals
Please see the file "LayoutDiagram.png" in folder Bob Z Virtual Signals. I am wondering if Simple Signal Logic will meet my needs. I am trying to control the signals at CP Kiski westbound (to left)
By rzeollaorcl · #138785 ·
Locked Re: Help with German Signals
Gary Probably easiest to create a head using the Double Output driver. This will display correctly when you select Dark, Red or Green. Create a mast using this head as a head controlled mast and as
By Suzie Tall · #138784 ·
Locked Re: Crossing in layout editor
The current is limited to less than the short wants (very high current) but more than any loco would want otherwise a loco moving onto a frog set correctly would trigger it. The frog voltage will move
By Dave Pallant · #138783 ·
Locked Re: Help with German Signals
FYI, with JMRI 4.8 or later the ESU SwitchPilot decoders have JMRI decoder definitions, are fully programmable on Program Track (read the ESU manual to see how to connect for Program Track Mode) and
By Dave Heap · #138782 ·
Locked Re: Locobuffer locking up from data overload?
Steve, Since you are using direct connectivity, JMRI is providing the timing for your flashing reds. So, you should not need to change anything in CATS, but make your changes in JMRI, as you first
By rodneyblack2000 · #138781 ·
Locked Re: Help with German Signals
The German signals don't work that way. Depending upon which signal type they are more complex in that they show aspects and can show more than one aspect at the same time depending upon whether there
By Michael Piazza · #138780 ·
Locked Re: Volume Control
This can only be done if the decoder supports such an option. I know that ESU decoders can be configured so that a function key works as a combined Volume/Mute key; a single press mutes or unmutes,
By Dave Heap · #138779 ·
Locked Re: JMRI 4.8 is available for download
Hi Fraser, I looked at your XML panel file, but am pretty sure the structure of the matrix signal masts is ok despite being written in 4.6. After I deleted all the extra stuff, except for 1 matrix
By Egbert Broerse · #138778 ·
Locked Help with German Signals
I am trying to set up a basic Signal with 3 states Red, Green, and Dark. I have tried all of the various Signal Heads. The signal is being driven by an ESU 51820 Accessory Decoder using 2 of the 4
By fotobahn · #138777 ·
Locked Version 4.8
Thanks to all that worked to bring us Version 4.8. It installed with no serious concerns and seems to address the burning issues. Good Job! Walt
By [email protected] · #138776 ·
Locked Re: Locobuffer locking up from data overload?
Steve, They are indicated on the label on the top. Left is LocoNet termination, Right is Railsync power. Dick :)
By dick bronson · #138774 ·