¿ªÔÆÌåÓý

Locked Re: Help with German Signals


 

FYI, with JMRI 4.8 or later the ESU SwitchPilot decoders have JMRI decoder definitions, are fully programmable on Program Track (read the ESU manual to see how to connect for Program Track Mode) and Program on Main (when fitted to layout).

Furthermore, the Single CV Programmer tool in JMRI can also be used. For Program on Main of these particular decoders with this tool, you need to select "Ops Accessory Byte", "Decoder Address" and use the decoder address (in the range 1-511) rather than the output address (in the range 1-2044).

Note that with SwitchPilot decoders, the usable range is limited to decoder addresses 1-510 and output addresses 1-2040 (commands to outputs 2041-2044 are ignored).
--
Dave in Australia

On 27 Jul 2017, at 7:12 AM, gratay@... [jmriusers] <jmriusers@...> wrote:

The signal is being driven by an ESU 51820 Accessory Decoder using 2 of the 4 outputs.

Join [email protected] to automatically receive all group messages.