¿ªÔÆÌåÓý


Cannot change horn, no bell #esu

 

I am trying to set up an ESU Loksound 5 decoder programmed by my dealer.?
?
The prime mover sound works, I can change the master volume ok, the lights work, I can dim the lights ok in the Function Outputs tab, I try to change CV163 (horn) and CV164 (bell) but the horn sound does not change and it sounds like a plastic toy. It does respond to the master volume.? Default Sound slots 3 (horn) at 225 and 4 (bell) at 70. Changing these values does nothing.
?
The bell has never made a peep... it is like there are no sound files loaded. (I do not have a Loksound programmer).?
?
What am I missing?
Thanks for your help,
-Paul in Utah
?
?
Bulletin: EMD 16-567D3 T
Manufacturer: ESU, Item number: S0758, Version: V5-R5


Re: LogixNG table editor and CSV question #logixng

 

Erik,

Try renaming the .txt file as .csv.

Dave Sand


----- Original message -----
From: "Erik84750 via groups.io" <e.arckens=[email protected]>
Subject: Re: [jmriusers] LogixNG table editor and CSV question
Date: Monday, May 26, 2025 1:10 PM

On Mon, May 26, 2025 at 03:35 PM, Dave Sand wrote:
Erik,
?
Does Excel have an option to export using tabs?
?
Dave Sand
?
Yes, but resulting in a .txt file.


OperationsPro new trains log format #operationspro

 

Dan, thanks for the expanded information in the trains log.? However, I can't figure out how you calculate the "Partial 28/80 cars" numbers.? Can you enlighten me?
?
Example:
?
Jon in San Rafael
?


Re: OperationsPro New feature, Routes #operationspro

 

Yea, but: To prevent a local move for trains that do only drops/lifts I have to do an edit, since you defaulted to local moves 'yes.'? Nit, and I've already edited my stuff.
?
Thanks,
?
Jon
?


Re: LogixNG table editor and CSV question #logixng

 

On Mon, May 26, 2025 at 03:35 PM, Dave Sand wrote:
Erik,
?
Does Excel have an option to export using tabs?
?
Dave Sand
?
Yes, but resulting in a .txt file.


Re: LogixNG table editor and CSV question #logixng

 

On Mon, May 26, 2025 at 06:59 PM, danielb987 wrote:

Erik,

Which version of Excel do you have? I have Excel 2010 and it supports export to TAB separated CSV file

I have MS Office 2010.
Two versions of export to .csv are presented when using "save as":
1. CSV (MS-DOS) *.csv
2. CSV separated by list-separation sign *.csv
?
In both cases the exported .csv file uses semi-colon (";"), as described in my previous message. Summary: due to the fact that EU decimal (,) and thousands (.) separation is different from US separation, a semi-colon is used as record separation.
If I want to use tab-separated records I have to export as "Text (tab separated) *.txt".
Causing my file to loose any Excel link.
?
Hence my upcoming request to have this third option when retrieving .csv files, (besides "tab" and "comma" separation) for "semi-colon" separation.


Re: Keyboard Shortcuts for PC and/or Mac for PanelPro... are there any?

 

On Sun, May 25, 2025 at 06:44 PM, Ken Cameron wrote:

The usual cut, copy, paste for text works on Windows. Cntl-X, Cntl-C, and Cntl-V.

?

But it may also be a function of the ¡®look and feel¡¯ selected in the Preferences. I always pick ¡®Metal¡¯ for my systems. You may have to try a few combos. But do a Save and Restart of JMRI after making a change.

?

-Ken Cameron, Member JMRI Dev Team

?

Shortcut keys work after changing appearance to Mac OS X. ?Thanks for the suggestion.

?

Gopal


Re: Error trying to add a panel in #panelpro

 

Thanks so much!! Appreciate the help.?
--

Heath @ Human[c]ity



Re: LogixNG table editor and CSV question #logixng

 

¿ªÔÆÌåÓý

Erik,

Which version of Excel do you have? I have Excel 2010 and it supports export to TAB separated CSV file.

See this documentation for Microsoft 365, Excel 2024, Excel 2021 and older versions.

Daniel


On 2025-05-26 08:32, Erik84750 via groups.io wrote:

On Sun, May 25, 2025 at 05:04 PM, Dave Sand wrote:
When you do the Excel CSV export, specify comma for the separator. ?It looks like you used the semi-colon in the first export. ?
?
When you do the LogixNG import, select the proper separator.
Dave Sand
?
Hi Dave, I discovered why my .csv file uses a semi-colon. Please see my previous message.
?
The only solution (in light of what I described there) is for JMRI to allow a third option (besides tab and comma) namely a semi-colon.
I intend on submitting this request to the developpers.
?
Erik
?


Re: Error trying to add a panel in #panelpro

 

Heath,

Yes. ?The destination JMRI install needs to be updated.

Dave Sand


----- Original message -----
From: "Heath @ Human[c]ity Junction" <heath@...>
Subject: Re: [jmriusers] Error trying to add a panel in #panelpro
Date: Monday, May 26, 2025 11:29 AM

I just realized that I am running the latest version of JMRI, but the version I am trying to load the panel onto is really old.?

I am guessing this is the issue, yes?
--

Heath @ Human[c]ity



Re: Error trying to add a panel in #panelpro

 

I just realized that I am running the latest version of JMRI, but the version I am trying to load the panel onto is really old.?


I am guessing this is the issue, yes?
--

Heath @ Human[c]ity



Re: Error trying to add a panel in #panelpro

 

Heath,

The file is not valid. ?The first three lines should look like the following:

<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet href="/xml/XSLT/panelfile-5-5-5.xsl" type="text/xsl"?>
<layout-config xmlns:xsi="" xsi:noNamespaceSchemaLocation="">

Dave Sand


----- Original message -----
From: "Heath @ Human[c]ity Junction" <heath@...>
Subject: [jmriusers] Error trying to add a panel in #panelpro
Date: Monday, May 26, 2025 11:09 AM

I am hoping someone has a thought on this error.?
I built a panel for a friends setup. I am trying to load the panel and this is the error I get.?
It is a simple panel, so I can just rebuild it, but I don¡¯t understand why it¡¯s not importing. What space??
?

--

Heath @ Human[c]ity



Re: DCC-EX Voltage/current meter #dcc-ex

 

Thanks, Daniel.
?
If that used to work on your hardware, I'm guessing the DCC-EX devs have removed support for it. You'd need to ask them why.
Here's what I get with the same commands on my CSB1:
[c] ?TX: Read Track Current Cmd?
[c CurrentMAIN 4 C Milli 0 4998 1 4998] ? RX: Meter reply: name CurrentMAIN, value 4.00, type C, unit Milli, min 0.00, max 4998.00, resolution 1.00, warn 4998.00
[JI] ?TX: Unknown Message: 'JI'
[jI 4 53] ? RX: Unknown Message: 'jI 4 53'
?
The response to your <c> request is <X>, which is the unhelpful "error" response. My <c> request returns a number of useful values that JMRI uses to populate the meter.
?
I could add support for the JI syntax to JMRI, but your result would be the same.
Here are the docs for JI:
Response: Repeated for each Channel/Track: <j I track current>
?> track: channel/track
?> current: current in milliamps
?
So you are seeing 0 for track and current, where I am seeing 4 and 53.
?
--SteveT


Re: Keyboard Shortcuts for PC and/or Mac for PanelPro... are there any?

 

I would really like undo as I always make a mistake right before I make a big change and have not saved.?

But I understand undo is a lot more than just adding a keyboard shortcut.?
--

Heath @ Human[c]ity



Error trying to add a panel in #panelpro

 

I am hoping someone has a thought on this error.?

I built a panel for a friends setup. I am trying to load the panel and this is the error I get.?

It is a simple panel, so I can just rebuild it, but I don¡¯t understand why it¡¯s not importing. What space??
?
--

Heath @ Human[c]ity



Re: Keyboard Shortcuts for PC and/or Mac for PanelPro... are there any?

 

Gopal,

If you are using the Metal L&F, then you need to use the control key instead of the command key.

Dave Sand



----- Original message -----
From: "Gopal Patnaik via groups.io" <gopalpatnaik=[email protected]>
Subject: Re: [jmriusers] Keyboard Shortcuts for PC and/or Mac for Panel Pro... are there any?
Date: Monday, May 26, 2025 9:40 AM

On Sun, May 25, 2025 at 04:08 PM, Dave Sand wrote:
Gopal,
?
Have you tried using standard shortcuts to paste into text fields?
?
Dave Sand
?
Unfortunately cmd-x, cmd-c, cmd-v do not work. ?Right clicking does bring up a contextual menu which allows for cut/copy/paste. This works, but is slower and not as familiar as the keyboard shortcuts.
?
Gopal


Re: Keyboard Shortcuts for PC and/or Mac for PanelPro... are there any?

 

On Sun, May 25, 2025 at 04:08 PM, Dave Sand wrote:
Gopal,
?
Have you tried using standard shortcuts to paste into text fields?
?
Dave Sand
?
Unfortunately cmd-x, cmd-c, cmd-v do not work. ?Right clicking does bring up a contextual menu which allows for cut/copy/paste. This works, but is slower and not as familiar as the keyboard shortcuts.
?
Gopal


Re: LogixNG table editor and CSV question #logixng

 

Erik,

Does Excel have an option to export using tabs?

Dave Sand


----- Original message -----
From: "Erik84750 via groups.io" <e.arckens=[email protected]>
Subject: Re: [jmriusers] LogixNG table editor and CSV question
Date: Monday, May 26, 2025 1:32 AM

On Sun, May 25, 2025 at 05:04 PM, Dave Sand wrote:
When you do the Excel CSV export, specify comma for the separator. ?It looks like you used the semi-colon in the first export. ?
?
When you do the LogixNG import, select the proper separator.

Dave Sand
?
Hi Dave, I discovered why my .csv file uses a semi-colon. Please see my previous message.
?
The only solution (in light of what I described there) is for JMRI to allow a third option (besides tab and comma) namely a semi-colon.
I intend on submitting this request to the developpers.
?
Erik
?


Re: Ad Hoc Changing Block Alternate Colour - Means of Showing Cab Allocation with DC Cab Control

 

Oh and it is good to have seen that block managing script, where and how it is described and syntax. All part of learning.


Re: Ad Hoc Changing Block Alternate Colour - Means of Showing Cab Allocation with DC Cab Control

 

On Mon, May 26, 2025 at 12:20 AM, Dave Sand wrote:
Traditionally, cab control consists of a rotary switch that routes the power from a number of cabs to a section of track.
?
The goal is to have JMRI handle the power switching using some unspecified type of hardware. ?The power routing would be based on selecting a cab and then a NX route. ?When the NX route is activated, the hardware would be notified of the cab setting for each affected block and the NX route on the panel would have the allocated track color changed based on which cab was selected.
A pithy summation, yes it makes sense, thanks for getting into the depth of this user's head :)
A detail adjustment and splitting the last sentence if I may...
When a cab is selected the allocated track colour associated with that cab is selected for all unallocated blocks. When the NX route is activated, the hardware would be notified of the cab setting for each activated block and the NX route on the panel uses the now cab dependent allocated track colour.
?
I feel that reflects, clarifies and separates the selection of the alternate colour and the use of it. This in a similar way to the separation of alternate colour selection in the edit block dialog and use of the alternate colour in NX route setting. The end result is the same as your description, just a slightly different order of getting there.
Is there any advantage/disadvantage you see in either method?
?