Locked Re: Caboose load status not printing
David, In the next test release 4.13.5, I've added check boxes to the "Manifest Print Options" window that will allow you to the show caboose and passenger car loads . Dan
By Dan Boudreau · #153770 ·
Locked Re: NCE GET Macro caused loss of existing Macros and loss of existing consists
Wain, It looks to me that the NCE command station crashed. Other than the Macro tool, was anything else communicating with the NCE command station?? The console shows a timeout to a valid macro
By Dan Boudreau · #153769 ·
Locked what is needed for seeing a train running on a physical layout through the computer?
Dave? I have been using JMRI for a while now, but I cannot seem to get where I want to be. I have a Digitrax system, DCS50, Windows Vista RR-Cirkits and loconet. I believe Dave has my layout (George
By george.pendergraft · #153768 ·
Locked Re: Problem exporting and importing the roster
Your fallback method (copying the "roster" folder) is the one I prefer. The Export Complete Roster option takes a long time to complete (with no busy/completed feedback) and actually produces a ZIP
By Dave Heap · #153767 ·
Locked Re: Caboose load status not printing
/g/jmriusers/message/153685 There are only 4 messages in the original thread. Your answer is in the second message. /g/jmriusers/message/153695 -- Peter Ulvestad JMRI
By Peter Ulvestad · #153766 ·
Locked Re: NCE AUI Sensors not detecting active or inactive - timeout message
Mike, Wouter is correct. I need to update this page: <http://jmri.org/help/en/html/hardware/nce/NCE.shtml#usblimitations> Also, as Wouter has said, ignore the el-cheapo RS232 to USB connectors you see
By Dave Heap · #153765 ·
Locked Re: Caboose load status not printing
Greetings all; My first note of this snag seemed to have been co-opted to the discussion of some other problem - so I'm re-printing it. ------------------------------------------------------ Another
By David Wakefield · #153764 ·
Locked Logix Change Doesn't Always Trigger Signal Head Change
I have numerous logix running on my layout and have for years.? I recently have added several signal heads and more logix to go with them.? Every once in a while, when the logix controlling a signal
By C Confair · #153763 ·
Locked Problem exporting and importing the roster
Hi, Today I attempted to export the roster from one computer to a new computer.? They are both Windows 10 and JMRI on both is 4.12. I used the "Export Roster" option and the "Import Roster" options.
By Marshall · #153762 ·
Locked Re: Is there any way to add time stamp to SensorLog.py? #scripting
Dave and Cliff, I was having some issues finding the lines you suggested Cliff, then saw Dave's suggestion and followed that.? It works as requested!!? Thank you for the quick reply and help, both
By Wain Schroeder · #153761 ·
Locked Re: Is there any way to add time stamp to SensorLog.py? #scripting
Wain, An alternate solution to Cliff¡¯s approach. Add "import time¡± Change the print line: print time.strftime("%Y-%m-%d %H:%M:%S"), mesg Dave Sand
By Dave Sand · #153760 ·
Locked Re: Is there any way to add time stamp to SensorLog.py? #scripting
The Preview seen on my screen prior to sending is not always in agreement with what is reported at the groups.io website 2018-11-21 09:24:41,939 script.SensorLog INFO - Sensor NS550 (East Yard) from
By Cliff Anderson · #153759 ·
Locked Re: Is there any way to add time stamp to SensorLog.py? #scripting
Wain, The modifications suggested here approximate what you asked for and were developed several months ago. The only tests that I have performed were on Digitrax DCS200 and NCE simulator. These
By Cliff Anderson · #153758 ·
Locked Re: Question about defining double crossovers
I may be totally off base since I am a newbie.? It was my understanding that (when using 4 motors) the "supporting turnout" was used to indicate the "pair" to select a route across the crossover.?
By Woody Hodge · #153757 ·
Locked NCE GET Macro caused loss of existing Macros and loss of existing consists
Hi, The use of macros in JMRI with the NCE PowerHouse command station has been a problem for several years and even as late as last year it was advised not to use the feature.? Last night, in
By Wain Schroeder · #153756 ·
Locked Re: NCE AUI Sensors not detecting active or inactive - timeout message
Wouter, thanks for the guidance. I will try that connection type. Mike Sent: Wednesday, November 21, 2018 7:13 AM To: [email protected] Subject: Re: [jmriusers] NCE AUI Sensors not detecting active
By michelplouffe4748@... · #153755 ·
Locked Re: Question about defining double crossovers
Jim, The advantage of throwing one pair or the other is that you have then defined the proper route through the turnouts so that you can set the proper polarity on the crossing rails. If you throw all
By dick bronson · #153754 ·
Locked Is there any way to add time stamp to SensorLog.py? #scripting
Hi, I have recently started using?SensorLog.py as a tool to validate block assignments on our layout and it works quite well, thank you.? The only change I would like to see would be to add a time
By Wain Schroeder · #153753 ·
Locked Re: NCE AUI Sensors not detecting active or inactive - timeout message
Hi Mike, Although I am not sure that this is the actual cause of what you are experiencing, the choice of using an NCE-USB with a PH-Pro is most definitely incorrect(*). That device is specifically
By whmvd · #153752 ·
Locked Re: Dispatcher - SML - auto-allocation problem
Mitchell, Following Steve's note above I've added the direction sensors to signal logic so that signals are set to danger when the section isn't allocated for my single track segments. ?It seems to
By paul@... · #153751 ·