DM-NVX-360 - USB Routing (NUX)
8
Hello Crestron Family, I have an NVX system here where we are now trying to implement NUX (USB-Over-IP) as well. The layout looks a little something like this: IFP110 Viewsonic Smartboard USB-B -> USB-A DM-NVX-360 Decoder -> Aruba CX-6100 PoE switch -> DM-NVX-360 Encoder USB-C -> USB-A Client OFE Computer Basically we are trying to get a ViewSonic touch screen display to act as another mouse on the client's computer via NVX USB routing. I have the NVX routing working fine and I manually route USB via layer 2 transport mode, and both NVX-360's say "Paired" and act like the USB is connected and will work, but my touch screen is not controlling the computer on the far end at all. I get the same reslult with layer 3 transport mode as well. I have tried both the HOST port and HID port on the touch screens decoder, but I get the same result. "Paired" but doesn't control anything. Perhaps someone has done this before and can tell me what I am missing? Thanks in advance for any input. -- Stephen H Programmer / Installation Technician
|
LightShark module
Hi, Has anyone ever worked with LightShark lighting setup (LS-1 console and LS-Node-4 DMX/ethernet node). Are there any crestron modules for LightShark? I couldn¡¯t find any in the usual places. Thanks!
|
Topics in Home Automation - New Article in Residential Tech Today
13
Smart motorized shades are a valuable addition to a smart home. However, a consumer has only had two choices when choosing shades: 1) Off-the-shelf shades that have limited options and typically won't fit your window. 2) Custom shades that include a wide range of fabric choices, are custom cut to exactly fit your window, and come with a premium price tag. SwitchBot's new Roller Shade bridges the gap between these 2 choices. While SwitchBot currently only offers their Roller Shade with a single fabric choice, the shade can be custom fit by the homeowner to exactly fit their window. My latest article looks at this new shade option for smart home owners in detail. You can find the article here: https://restechtoday.com/reviewing-the-switchbot-smart-roller-shades/ For those interested in earlier articles that I've written, you can find those here: https://restechtoday.com/author/jaybasen/ For these interested in even earlier content that I wrote, you can find it all here though older content has formatting issues due to a transfer from blogspot to wordpress. https://topicsinhomeautomation.wordpress.com/ Thanks
|
Sensibo and crestron stopped working
12
I am hoping that @jbasen will see this. I have been using your sensibo module for a few years and it has been working fantastically well. Today the module has started erroring. Seems to be an SSL issue. The error is: 00:20:29.047: [Console Data] : Sensibo_Air - Refresh - Error Sending Device Command: Crestron.SimplSharp.Net.Https.HttpsException: Peer certificate cannot be authenticated with given CA certificates 00:20:29.047: [Console Data] : at Crestron.SimplSharp.Net.Https.HttpsClient.ProcessInternalError(HttpsClientResponse response) 00:20:29.047: [Console Data] : at Crestron.SimplSharp.Net.Https.HttpsClient.d(HttpsClientRequest A_0, Boolean A_1) 00:20:29.047: [Console Data] : at Crestron.SimplSharp.Net.Https.HttpsClient.TryDispatch(HttpsClientRequest aRequest) 00:20:29.047: [Console Data] : at Crestron.SimplSharp.Net.Https.HttpsClient.Dispatch(HttpsClientRequest aRequest) 00:20:29.047: [Console Data] : at Sensibo_Air_Integration.Sensibo_Air.Refresh() 00:20:29.047: [Console Data] : at Sensibo_Air_Integration.Sensibo_Air.Initialize(String Device_ID, String API_Key, Int16 Default_Target_Temperature, String Default_Temperature_Unit, Int16 Debug) 00:20:29.047: [Console Data] : at UserModule_SENSIBO_AIR_V1_6.UserModuleClass_SENSIBO_AIR_V1_6.INITIALIZE_OnPush_0(Object __EventInfo__) 00:20:29.047: [Console Data] : at Amib.Threading.Internal.WorkItem.o() 00:20:29.047: [Console Data] : at Amib.Threading.Internal.WorkItem.Execute() 00:20:29.047: [Console Data] : at Amib.Threading.SmartThreadPool.e(WorkItem A_0 Thanks
|
Alternativce SACN module
7
Hi, I?m using the ?SACN SenderDirectSockets¡± module from the SIMPL device database to control an Enttec Ethergate Artnet/SACN to DMX gateway. In general, it works. However, it seems as if the module sends out all 512 channels, even if I change only one of them. This is very unfortunate, as I?m using an Enttec S-Play mini to send out prerecorded scenes to my fixtures via the Ethergate in parallel to the Crestron processor. Is there any alternative to SACN module (Artnet would be OK as well) available that sends out only the values for the DMX channel that has actually changed? Thanks, Thorsten
|
DSC Neo Pro
Has anyone tried to use the DSC Neo IP modules with DSC Neo Pro? Thanks
|
Topics in Home Automation - New Article in Residential Tech Today
Aqara has just announced significant new support for the Matter Smart Home Standard. My latest article explores the details of this announcement. You can find the article here: https://restechtoday.com/aqara-announces-new-support-for-the-matter-smart-home-standard/ For those interested in earlier articles that I've written, you can find those here: https://restechtoday.com/author/jaybasen/ For these interested in even earlier content that I wrote, you can find it all here though older content has formatting issues due to a transfer from blogspot to wordpress. https://topicsinhomeautomation.wordpress.com/ Thanks
|
TST-1080 (html5 Construct) Subpage and text punch-through
2
In VT-Pro, overlaying text or a subpage over a button enables you to interact with controls underneath. This no longer appears to be the case in Construct. I have two instances in this particular project: * I have a footer menu subpage with a clear background - I'm using a Div (border) to form a background image with a button acting as a tab to hide or show this menu |--tab--| |--------------| | menu | |--------------| The area each side of the tab is clear. One of the buttons in the menu slides up a wireless mic list from the bottom of the page (under the menu) and then appears on the main page. The bottom mic in the list cannot be controlled because the menu clear space sits over it. I can't change the UI as this is a pre-agreed UI based on an existing TSW VTP project and I'm not allowed to deviate. * I have a button in a widget list that has 3 text objects over it containing event information This takes the form of: number - event name - event time Placing the text straight on the button just looks like shit as the placement gets messed up with the List header and it's impossible to get the text to line up correctly. In VTP, this works perfectly, in Construct, it appears that you can't pass a press event through a text object. Anyone know if it's possible to enable press-through?
|
TST-1080 image resource path
5
I did ask this on the Crestron Discussions forum, but it seems to take days to get a response there. So posting here in the hope that you guys can help out. On a TSW panel, I can send an image to the panel like this: \images\icon - camera 100px wht.png The actual location on the panel is in: /display/swf/images On a TST, sending \images\icon - camera 100px wht.png does not work. The location on the TST where this graphic is stored appears to be: /display/app/project/assets/img Attempting to send: \display\app\project\assets\img\icon - camera wht 100px.png Yields no image What is the correct path to retrieve an image from the TST? I've tried a few combo's but nothing seems to work.
|
How to control DT8 driver in Crestron DIN-Dali2
16
Hello everyone, I want to control DT8 driver using DIN-Dali2 module. I have already controlled DT6 drivers. My issue is when I add DT8 driver, it takes one address. How I can control a CCT led strip using simpl program. Currently I have CP3 processor and up to date firmware and database. Needs help/guidance to configure DT8 drivers. Thanks in advance for support.
|
question about using ODT censor to turn on/off TV
Hi all, For a newly installed Flex Teams room, the client wish to turn on / off the TVs (2 x LG) automatically based on occcupancy. aside form the MX70 kit, I'm using an RMC4 and CEN-ODT-POE. I basically have the ?Room_Occupied / Room_Vacant? going to ?Multiple One shot? then to ?Crestron Connected ?. A senior programmer suggested i insert a ?Toggle? between the ?One Shot? and ?Crestron Connected?. Any reasons/advantages doing it this way? Thanks,
|
Taurus UCX Series Module or TCP/IP Control
3
Hi All, Has anyone controlled the Lightwave Taurus UCX series device from the Crestron processor? If anyone shares the module or direct commands, it would be very useful for me. Thanks Bharath B
|
Autonomic M5Pro Integration
6
Is anyone aware if these new autonomic media servers integrate as seamlessly as the old ones? Do we still access the web gui and enter IPID and processor information to connect and get online, then just use CRPC joins on media object? I do not see the specific device to add to my program, wondering if I can just add it as an MMS-5? Or do these not integrate the same way the E series did? Thanks in advance.
|
UMC Creation issue
2
I'm wondering if anyone has started to see this lately. It's been pinching me this week... When making or updating .UMCs I will often have version as the suffix. ex: Module v1.0.1 Historically when I SaveAs, the Windows SaveAs dialog has the .umc type already selected and everything is good, like for decades... This week I noticed that when I update/save a module ending in a dot-#, even though Windows dialog has the type, the module gets saved WITHOUT the .umc extension. It will be saved as file name - Module v1.0 (Not Module v1.0.1.umc) and of course has no file reference. This is an easy fix, except for the wasted time and process workflow, but just wondering if others have seem this. Not sure if this is SMW, Windows or general digital crap...but I've only just started seeing this. It could be my PC, Windows 11...
|
NAX/AES67 Streams disappearing from some NVX devices
3
We have over 60 NVX endpoints installed in a building and a few weeks ago the audio streams stopped working on the NVX-351 and NVX-360 units, but still work on the E20 units. Video streams still work on all the units, but the audio streams just disappear from the stream list in Q-SYS Designer (the cores do the audio routing and processing for the building). If we subscribe to video and audio on a decoder connected to a TV via HDMI there is video but no audio as well. A reboot brings the stream back for 3-5 minutes and then poof! Gone again. IGMP snooping is enabled on all the switches, as is QoS, and no changes were made recently on the network configuration or other devices, so we're all a little baffled.
|
CP3 FW
6
Hi All, I have not been updating CP4's to the latest FW versions as, though I don't use the HomeKit features, I have no confidence that there will be other issues related to the HK/OpenSSL that will bite me... Thus I've paused at the xxx_2.8003.00056.01.puf firmware for 4-series. Regarding 3-series (CP3 primarily) I have paused at the xxx_1.8001.0251.puf Firmware. The latest 3-series version is xxx_1.8001.0295.puf. release notes don't mention anything about the HK/OpenSSL issue so I'm assuming that this is not an issue with this platform. Can others chime in about your use/dis-use and experience with this FW version? TIA!
|
Lutron QSX firmware update broke modules?
8
I'm going on hearsay here but I was told Lutron recently pushed from the cloud an update to their QSX processors. I didn't know this was a thing but apparently it is. Coincidentally, around the same time a system we have stopped being able to control shades. This is using the Simpl module "Lutron HomeWorks QSX Command Processor v1.3" which is in the Crestron module store, but I know it's written by Control Concepts. Has anyone heard of this or has systems that have stopped working? if I turn on the debug option I get a lot of CP4>[FAh][E0h][01h]LutronLeapCommLib1[ Reconnect!!! ] [FBh][FAh][E0h][01h]LutronLeapCommLib1[ Connecting to: 192.168.1.112 ] [FBh][FAh][E0h][01h]LutronLeapCommLib1[ SocketStatusChange: SOCKET_STATUS_NO_CONNECT ] [FBh][FAh][E0h][01h]LutronLeapCommLib1[ Reconnect!!! ] [FBh][FAh][E0h][01h]LutronLeapCommLib1[ Connecting to: 192.168.1.112 ] [FBh][FAh][E0h][01h]LutronLeapCommLib1[ SocketStatusChange: SOCKET_STATUS_NO_CONNECT ] [FBh][FAh][E0h][01h]LutronLeapCommLib1[ Reconnect!!! ] [FBh][FAh][E0h][01h]LutronLeapCommLib1[ Connecting to: 192.168.1.112 ] The QSX processor is absolutely at the correct address and pingable from my processor. So we're curious if something they did broke this module's ability to communicate, or something with their authentication, or maybe it's some unrelated issue unique to this site. Rebooting both ends etc all tried. TIA OP
|
Programmatic Control of Reserved Joins
13
I'm pretty sure that the answer is no, but is there any way to trigger a reserved join number programmatically? EX: I want to launch the App Setup screen (res.Join 17242) from a running VTP project, but I want to make it a P+H instead of just a press on a button. TIA!
|
Crestron Home RAVA issues
12
Hello, I'm coming from an AP3 system and just finished setting up Crestron home OS 4. I'm facing two major issues between the 2N and the TSW-1070: 1- Whenever a call is issued from 2N the touch screen will only display the outdoor camera with action buttons as long as the call is still ongoing so panel needs to keep ringing otherwise it's not possible to see who's outside 2- It seems that it's impossible to change the ringtone of the touch panel and I must admit I can't stand it. With the AP3 it was a bit more complicated but one a call is initiated a 3 seconds ringtone is enough to display the RTSP page with the action button until I open the door or reject. Also I was able to play any ringtone using http commands... All this seems impossible with OS4 or I'm missing something? Thanks.
|
Lumens VC series camera control lost after web page login
camera works fine with IP connection (UDP) after logging into cameras webpage, crestron control is lost requires client reboot of processor to get control back
|