¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: NVX Switchingh in simpl
Is the switch on the same network as the processor or a separate vlan ? Regards Bruce
By pearce.bruce <bruceadsl@...> · #242365 ·
NVX Switchingh in simpl
Hi, First NVX install, and having a struggle switching from the program. Following on from the advice previously given here, I have installed a Luxul POE switch and added my E30 and D30 units. I have
By nick_masterson_uk · #242364 ·
Re: Simpl compiled zipped file is missing sgd
Yes I have seen this issue.? I try to remember to manually add the sgd files manual to the zip file but many times I forget.
By Steve Kuehn · #242363 ·
Simpl compiled zipped file is missing sgd
I seems like the compiled zip file generated by simpl windows does not include the smart graphics definition anymore... If I send the file to somebody, there will be a bunch of warnings popping up
By fabiodaubermann · #242362 ·
Re: RS-232 commands that only worked over an unconventional termination...
What pins were connected on each end? Was is really only the program that was changed, or was hardware changed as well? To answer some of your curiosity: As it happens, RS-232c voltage specifications
By MSTC · #242361 ·
Re: RS-232 commands that only worked over an unconventional termination...
Sounds like grounding/short issue of some sort.
By ZS · #242360 ·
Epiphan Livescrypt Integration?
I've been told to integrate this into a Council Chambers build. No published API or control inputs. All documented control is either from the local web interface, Epiphan Cloud, or the touchscreen
By Scott Pidzarko · #242359 ·
Re: RS-232 commands that only worked over an unconventional termination...
It wasn't that. The code worked perfectly once I routed it through a room controller, rather than the oddly run COM port coming out of the processor. I'm confident the Serial settings were set
Re: RS-232 commands that only worked over an unconventional termination...
And how many spaces may need to be in there . . .? that¡¯s why I only put the RSPW Their protocol designer is probably the same person that determines how much a traffic ticket costs in Ca.????
By MSTC · #242357 ·
Re: RS-232 commands that only worked over an unconventional termination...
Except for the versions that required RSPW 2\x0D and a few iterations 1 had to be used instead of 2 (instead of 2 being network + serial active, 2 seemed to be network only, 1 kept serial alive) --
By Lincoln King-Cliby · #242356 ·
Re: RS-232 commands that only worked over an unconventional termination...
Haven't you guys heard of RSPW2? ?\x0D?
By eagrubbs · #242355 ·
Re: RS-232 commands that only worked over an unconventional termination...
RSPW . . . Sharp! that's your problem!!...HaHa!! The old units that I dealt with had an issue where the serial port would turn off after the set was turned off, which would require IR to run it
By MSTC · #242354 ·
Re: Resi NVX install - cost effective compatible 24 port switch
I have had excellent results for small systems using Snap AV Araknis 310 series switches.? You need to set up IGMP querying as it is not ready to rock out of the box.? They have a white paper on
By MSTC · #242353 ·
Re: VTpro compiling project
Above is especially true if you are compiling for Crestron app with custom theme and using new PC that didn't have old AIR installed. Process Explorer is really helpful tool!
By ZS · #242352 ·
Re: VTpro compiling project
I've been tracking a few reports of this behavior in the last few months (hanging when compiling a project with a custom theme). Most recent case was solved by installing Smart Graphics 2.15.06.01
By Dave H - Crestron True Blue Tech Support Engineer Since 2014 · #242351 ·
VTpro compiling project
Hello, I am trying to do some changes in my old project, but Vtpro hangs when is compilied. Looks like a problem with .swf extension. I am using NTD EZ Theme Horizon. Tryed reinstall and upgrade all
By kamil.rukat@... · #242350 ·
Re: Alexa thermostat control
AVmaster, In debugger, are you seeing any commands triggered by the Voice modules when you try to set the mode to something other than OFF? I know that both the DIN-THSTAT and HZ-THSTAT have slightly
By ckangis · #242349 ·
How to get TSW-xx70 or TS-770 to use SRTP ?
Hi, I am trying to connect all my Crestron panels to a phonesystem 3CX on a Raspberry. I got a TSW-1060 and a TSW-1070? working but another TSW-1070 and a TS-770 can't call my 2N station and all
By stefan.mehre · #242348 ·
Re: Need help
Thank you all. I tried one shots and it has worked. Israel
By Israel Banini <ikbanini@...> · #242347 ·
Re: Carrier Infinity Thermostat Control through Crestron
Hopefully Lincoln your modules will be a bit less buggy than the old App Market ones for the SAM we have been using for years.