Re: Simpl compiled zipped file is missing sgd
Also seen this recently when getting files from our other programmer. He had to send me the SGDs manually. Why did they break this feature? Its getting ridiculous these days. I am on software and
By
@johnmax
·
#242370
·
|
Re: NVX Switchingh in simpl
Hmm, well I now have it working on a 2-series........ I have written a quick and dirty module to collect the input stream locations from the E30's and route to the D30's on receipt of an analogue
By
nick_masterson_uk
·
#242369
·
|
Re: NVX Switchingh in simpl
Single subnet flat network 192.168.1.0 (setup in my office and stand-alone from anything else). I should mention that the processor in use is a CP2E as this is what is currently installed on the site
By
nick_masterson_uk
·
#242367
·
|
Re: Resi NVX install - cost effective compatible 24 port switch
I have installed a Luxul 4424P and it was a breeze to set up. Also as its the AV version it looks really nice in the rack as the lights are on the front and the RJ45s on the back.
By
nick_masterson_uk
·
#242366
·
|
Re: NVX Switchingh in simpl
Is the switch on the same network as the processor or a separate vlan ? Regards Bruce
By
pearce.bruce <bruceadsl@...>
·
#242365
·
|
NVX Switchingh in simpl
Hi, First NVX install, and having a struggle switching from the program. Following on from the advice previously given here, I have installed a Luxul POE switch and added my E30 and D30 units. I have
By
nick_masterson_uk
·
#242364
·
|
Re: Simpl compiled zipped file is missing sgd
Yes I have seen this issue.? I try to remember to manually add the sgd files manual to the zip file but many times I forget.
By
Steve Kuehn
·
#242363
·
|
Simpl compiled zipped file is missing sgd
I seems like the compiled zip file generated by simpl windows does not include the smart graphics definition anymore... If I send the file to somebody, there will be a bunch of warnings popping up
By
fabiodaubermann
·
#242362
·
|
Re: RS-232 commands that only worked over an unconventional termination...
What pins were connected on each end? Was is really only the program that was changed, or was hardware changed as well? To answer some of your curiosity: As it happens, RS-232c voltage specifications
By
MSTC
·
#242361
·
|
Re: RS-232 commands that only worked over an unconventional termination...
Sounds like grounding/short issue of some sort.
By
ZS
·
#242360
·
|
Epiphan Livescrypt Integration?
I've been told to integrate this into a Council Chambers build. No published API or control inputs. All documented control is either from the local web interface, Epiphan Cloud, or the touchscreen
By
Scott Pidzarko
·
#242359
·
|
Re: RS-232 commands that only worked over an unconventional termination...
It wasn't that. The code worked perfectly once I routed it through a room controller, rather than the oddly run COM port coming out of the processor. I'm confident the Serial settings were set
By
musichascolors
·
#242358
·
Edited
|
Re: RS-232 commands that only worked over an unconventional termination...
And how many spaces may need to be in there . . .? that¡¯s why I only put the RSPW Their protocol designer is probably the same person that determines how much a traffic ticket costs in Ca.????
By
MSTC
·
#242357
·
|
Re: RS-232 commands that only worked over an unconventional termination...
Except for the versions that required RSPW 2\x0D and a few iterations 1 had to be used instead of 2 (instead of 2 being network + serial active, 2 seemed to be network only, 1 kept serial alive) --
By
Lincoln King-Cliby
·
#242356
·
|
Re: RS-232 commands that only worked over an unconventional termination...
Haven't you guys heard of RSPW2? ?\x0D?
By
eagrubbs
·
#242355
·
|
Re: RS-232 commands that only worked over an unconventional termination...
RSPW . . . Sharp! that's your problem!!...HaHa!! The old units that I dealt with had an issue where the serial port would turn off after the set was turned off, which would require IR to run it
By
MSTC
·
#242354
·
|
Re: Resi NVX install - cost effective compatible 24 port switch
I have had excellent results for small systems using Snap AV Araknis 310 series switches.? You need to set up IGMP querying as it is not ready to rock out of the box.? They have a white paper on
By
MSTC
·
#242353
·
|
Re: VTpro compiling project
Above is especially true if you are compiling for Crestron app with custom theme and using new PC that didn't have old AIR installed. Process Explorer is really helpful tool!
By
ZS
·
#242352
·
|
Re: VTpro compiling project
I've been tracking a few reports of this behavior in the last few months (hanging when compiling a project with a custom theme). Most recent case was solved by installing Smart Graphics 2.15.06.01
By
Dave H - Crestron True Blue Tech Support Engineer Since 2014
·
#242351
·
|
VTpro compiling project
Hello, I am trying to do some changes in my old project, but Vtpro hangs when is compilied. Looks like a problem with .swf extension. I am using NTD EZ Theme Horizon. Tryed reinstall and upgrade all
By
kamil.rukat@...
·
#242350
·
|