Re: AnyCon Camera DVR/NVR recorders

 

Interesting, Lincoln! thanks, I chase this...


Re: DGE100 browser and touchpanel wake

 

I have done this for a dedicated browser only TSW as well as a panel that is just for the Sonos app. Once the panel boots up it goes right into the desired application. You can just have a blank first page, and under Transition Complete Digital Join just use the reserved join needed- for Open Browser it would be 28600. That way then the page is drawn it fires that join and opens the browser. If you add the browser embedded app to that page you can specify the File- Default Path which would be the browser home page.??


Re: D3 Multiple loads grouped as one

 

What are you using to "show" the D3 loads? Are you using a Simpl program to interface with D3 or are you using the UI generated from within D3 to a iPad or touch panel? If the latter, then you can edit the VTP from within D3 and on your buttons to control you can add the other lights to that button. At least last time I used D3 for generating a UI you used to be able to do that.?


Re: IR control thru DM RMC Weirdness

 





Get
On Feb 20, 2023, at 6:34 PM, Steve Kuehn <steve@...> wrote:

Wow!? I am shock that this is the first time you have ever seen this issue.? Yes this is a well known problem with the DM-RMC-100-C and I don't believe Crestron has ever come up with a fix for it.

The issue is the DM-RMC-100-C does not handle an IR codes properly that has both at header and a repeat section.??? LG uses header length of 34 and then a very short repeat section of length two.? Yamaha is similar.

Basically what you need to do is generate 2 IR codes each for functions like vol+, vol-, up, down, left, and right.? For example, for up you will have a Up-Pulse and a Up-Hold. For the Up-Pulse, you will remove the repeat section of the code so it? just sends out a single 34 length header IR pulse.? For the Up_Hold, you will take the 34 length header and replace the repeat section with it -- so in the end you have a 0 length header and a 34 length repeat section which used to be the header. Then in your SIMPL program send the header pulse when the client pushes a button.? If the client holds the button, then send out the repeat code.

Probably be best to use a program like VERT to convert Crestron codes into standard hex codes.? Then manually edit the hex codes and then import them back into Crestron.

Good luck,
Steve


Re: AnyCon Camera DVR/NVR recorders

 

¿ªÔÆÌåÓý

From Google I suspect you mean Avycon instead of AnyCon¡­ anyway, from what I¡¯ve noticed a healthy proportion of the better the ¡°random brand¡± NVRs are either Hikvision or Dahua OEM under the hood ¨C which may be a significant compliance concern if the client has contractual relationships with the US government or their first tier contractors, but I digress.

?

A lot of times the MAC will give the OEM away if you can get to that, or comparing pictures of back panels will confirm the suspicion (there¡¯s a lot more customization in front panels it seem ¨C probably because it just takes a quick plastic mold ¨C but back panels tend to maintain some family signatures) note that you might not find an exact match because Hikvision, at least, seems to heavily segment regionally so it¡¯s possible to find an ¡°QWE¡± brand device in North America where the Hik model it is based on is only available in China or the EU or ¡­

?

?

Lincoln

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of ckangis
Sent: Monday, February 20, 2023 4:28 PM
To: [email protected]
Subject: [crestron] AnyCon Camera DVR/NVR recorders

?

Hi All,
A dealer I work for has upgraded their older Digital Watchdog camera DVR which we had doing what we needed for control via IR.
They have changed this to an AnyCon?AVR-NT532C 32-ch DVR.?
I have never even heard of this product line. Tech support is very nice, but has no idea who Crestron is (no surprise). they've sent me an IR codes doc that is limited in both explanation and command set.

Any chance any of you have even heard of this, or better dealt with them??
TIA


AnyCon Camera DVR/NVR recorders

 

Hi All,
A dealer I work for has upgraded their older Digital Watchdog camera DVR which we had doing what we needed for control via IR.
They have changed this to an AnyCon?AVR-NT532C 32-ch DVR.?
I have never even heard of this product line. Tech support is very nice, but has no idea who Crestron is (no surprise). they've sent me an IR codes doc that is limited in both explanation and command set.

Any chance any of you have even heard of this, or better dealt with them??
TIA


IR control thru DM RMC Weirdness

 

Hi All,
In all my years, I don't remember seeing this issue, anyone seen this and have a fix?
I have an LG TV IR driver (I've actually tried a few) that need to control (3) little/cheapo LG panels in secondary bedrooms.
They are connected to the standard DM-RMC-100-C room boxes. DM8x8 and RMCs are all 1080p level video and have latest FW for their capabilities.
when firing any command, the command is latched for ~2 seconds (esp. bad for Vol +/-). I can tell by the function as well as my Xantech emitters having the talk-back LEDs flasshing for 2 sec.
When I try the same IR driver(s) on the CP3 ports they just pulse for ~ 0.05 sec like you'd expect.
I have tried applying the 'pulse IR' filter via the Device Learner tool, with identical results...

It seems that the RMCs 'don't like' this IR driver (I didn't have time to test another driver on the RMC).

Anyone seen this behavior, and have a fix for it??? TIA!


VKM-WIN with virtual controller?

 

hope all is good. I am first time working with virtual controller and wondering if anyone can help me here. I have been using VMK-WIN to shutdown remote PC with controllers like cp3 or cp4 and now since i am using Virtual controller so I am not sure if i can Use the VKM-Win or not. seems like remote PCs are not connecting to my virtual controller even though I can ping it and controller can ping the remote PC


Re: SkyVue TV Module

 

TV ON :?\xA0\xF0\x55\xFF\xAE\x51\r
TV OFF:?\xA0\xF0\x55\xFF\xAF\x50\r


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

mine is 4K, thats why telnet still work.?
4KZ will required custom program via third party controller.?


Re: IP Table Offline #simplwindows

 

Thanks guys.

I had loopback in the devices as well. What throws me off is that in toolbox when I use easy config cause it wont let me connect to the PRO3 with device discovery that it had 0 entries in the ip table. I loaded the program for the 8th time or so and now its populating. TSR is online and so is the switch.


Re: IP Table Offline #simplwindows

 

First off, I am assuming you are using SIMPL and not Crestron Home.

Like Phil said, when you load the PRO3 program, it will take care of the IP table in the PRO3.

But you don't use the 127.0.0.1 loopback address in the TSR-310.? Instead you need to manually set the address in the TSR-310 IP table to point to your PRO3.?

Also check if you have SSL enabled in the PRO3.? Open a console to the PRO3 and enter
SSL
That will tell you if SSL is enable or not.

If SSL is enabled on the PRO3, you also need to enable it on the TSR310.? Be default, authentication/SSH is enable on the TSR-310 but SSL is turned off.

Finally make sure neither the PRO3 or TSR310 is blocking any IP addresses.? Open a console on each and execute

listblocked

Use the

remblocked

to unblock any devices.

Good luck,
Steve


Corbin.Lovering@
" Made sure to use the 127.0.0.1 loopback on everything"


Re: DGE100 browser and touchpanel wake

 

Doesn?t work unfortunately - same issue. Really weird.
Another approach i wanted to follow is just to hardcode the URL into the VTPro-project.
I put an page on the project, then added the embedded browser object with a 0 visibility join, then filled in the desired URL into the object, hoping that this would just load the page and show the embedded browser.
Unfortunately, that doesn?t work, either. It shows just the empty page, but not the browser object...


Re: IP Table Offline #simplwindows

 

Don't do anything manual with the IP Table in the processor. The code will take care of that. Add the IP Table entries in your remote devices - have them point at the processor IP address or hostname if you have good DNS.?



On Sun, Feb 19, 2023, 10:53 AM <Corbin.Lovering@...> wrote:
Hello all,?
I'm a complete newbie with zero experience with Crestron products. I managed to crawl my way through P101 and 201 courses and was instructed to not go to 301 or masters without some real experience or I'll be lost and lost I am now.

I have a Pro3, CEN-SWPOE-16, TSR310 (wifi) and nothing else to play with. They all have current firmware, I've loaded my project file to the TSR and sent the compiled file to the Pro3. I've verified correct IPID's on all devices. Made sure to use the 127.0.0.1 loopback on everything. It still shows both the switch and the TSR are offline and I can clearly ping all three devices. I have a CP3 as well in case something is wrong with this processor and I was going to try both of my TSW-1060's to test with and see if I could get those online.

Is there something I can do, or possibly doing wrong?


IP Table Offline #simplwindows

 

Hello all,?
I'm a complete newbie with zero experience with Crestron products. I managed to crawl my way through P101 and 201 courses and was instructed to not go to 301 or masters without some real experience or I'll be lost and lost I am now.

I have a Pro3, CEN-SWPOE-16, TSR310 (wifi) and nothing else to play with. They all have current firmware, I've loaded my project file to the TSR and sent the compiled file to the Pro3. I've verified correct IPID's on all devices. Made sure to use the 127.0.0.1 loopback on everything. It still shows both the switch and the TSR are offline and I can clearly ping all three devices. I have a CP3 as well in case something is wrong with this processor and I was going to try both of my TSW-1060's to test with and see if I could get those online.

Is there something I can do, or possibly doing wrong?


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

On Thu, Feb 16, 2023 at 03:54 PM, <fujiakai@...> wrote:
if you have the unit, test with with Putty from you laptop.
?
the unit i have works on TCP port 23.
?
?This reply is for Fuiakai. Is your test device a 4K or a 4KZ? I tried a telnet connection port 23 on the 4KZ and the device rejected the connection.?


Re: DGE100 browser and touchpanel wake

 

¿ªÔÆÌåÓý

It¡¯s been a while but I¡¯m pretty sure there¡¯s a ¡°home page¡± serial which you can call the desired URL which won¡¯t instantiate another tab

Tim Greenbank

Control Systems Engineer


On 18 Feb 2023, at 23:06, Thorsten K?hler <thorsten.koehler@...> wrote:

?

Hi,

?

i?d like to have a DGE100 just display a single webpage.

I?ve designed a VTPro project consisting of just a single page with a browser embedded app in it.

I?m feeding the desired URL into the app and the webpage is showing up as it should.

I?ve tied the ¡°touchpanel sleep/wake¡± Manager for the DGE100 to a motion detector, so that everytime somebody enters the room, the ¡°wake¡± signal is triggered.

That works as well, the panel is waking up. However, in addition to waking up the panel, the embedded browser opens a new empty tab.

?

Any ideas why this is happening?

?

Thanks,

Thorsten


Re: Lutron Grafik Eye QS IR driver

 

Thanks Jay, but it was a false alarm. 30 seconds after I sent that post, the technician called and said they figured out the problem.

There was a serial adapter plugged into the Grafik Eye, that they later decided not to use. However, no one bothered to disconnect the un-used adapter, which apparently disables the IR jack and sensor. As soon as it was unplugged, the IR commands started working.

Hopefully this will save someone else some time in the future.

Thanks again.

--- On Saturday, February 18, 2023 at 6:12 PM, Jay Basen wrote:

Tony,

There are some Grafik Eye codes on Remote Central that might work for
you if someone doesn't have a ready made driver.



Hope this helps

Jay


On 2/18/2023 3:08 PM, Tony Golden wrote:

Does anyone have an IR driver for the Grafik Eye QS. All the ones I've found
are for the "original" Grafik Eye (not the QS) and don't seem to work.

I couldn't find an IR driver on Lutron's site, but I did find an Excel
spreadsheet with IR codes - however they're only for controlling shades, and
not lights.

The unit was previously controlled by an RTI system, but those converted
codes don't work either. I got a lot of error messages when copying the hex
codes to Deal, so I used Device Learner instead. Still didn't work...

Thanks in advance!


Re: Lutron Grafik Eye QS IR driver

 

Tony,

There are some Grafik Eye codes on Remote Central that might work for you if someone doesn't have a ready made driver.



Hope this helps

Jay

On 2/18/2023 3:08 PM, Tony Golden wrote:
Does anyone have an IR driver for the Grafik Eye QS. All the ones I've found
are for the "original" Grafik Eye (not the QS) and don't seem to work.

I couldn't find an IR driver on Lutron's site, but I did find an Excel
spreadsheet with IR codes - however they're only for controlling shades, and not
lights.

The unit was previously controlled by an RTI system, but those converted codes
don't work either. I got a lot of error messages when copying the hex codes to
Deal, so I used Device Learner instead. Still didn't work...

Thanks in advance!





Re: LCD Toshiba

 

receiving "FF" might be an indication for a wrong baud rate, maybe try different ones.

BTW: you mentioned CEC control earlier, any luck with that? Do you have something like a DM receiver that can insert CEC commands?
There are CEC modules in the database, just play with it

Best regards
Crestronfreak55