Re: Sonos Unhandled Exception

 

Have seen these errors throughout the awesome Sonos "integration" years, and I know they disappeared with newer firmware. What FX are you running on this system??


Re: DGE100 browser and touchpanel wake

 

¿ªÔÆÌåÓý

OK, thanks.
I?m currently traveling, but i?ll give it a try when i?m back in the office.

That?s actually exactly the setup i?d like to go for.

?

Thanks,

Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von johnh via groups.io
Gesendet: Dienstag, 21. Februar 2023 14:55
An: [email protected]
Betreff: Re: [crestron] DGE100 browser and touchpanel wake

?

I have done this for a dedicated browser only TSW as well as a panel that is just for the Sonos app. Once the panel boots up it goes right into the desired application. You can just have a blank first page, and under Transition Complete Digital Join just use the reserved join needed- for Open Browser it would be 28600. That way then the page is drawn it fires that join and opens the browser. If you add the browser embedded app to that page you can specify the File- Default Path which would be the browser home page.??


Re: IR control thru DM RMC Weirdness

 

A trial version can be obtained here:


Geoff

On Tue, Feb 21, 2023 at 7:27 PM Tony Golden <mrgolden@...> wrote:
Geoff Reynolds wrote an IR utility several years ago, that could easily swap the one-time and repeat codes, in addition to a few other useful functions.

I no longer have the link, but maybe he'll chime in with it.



> --- On Monday, February 20, 2023 at 6:35 PM, Steve Kuehn wrote:
>
> Yes this is a well known problem with the DM-RMC-100-C and I don't believe
> Crestron has ever come up with a fix for it.
>
> The issue is the DM-RMC-100-C does not handle an IR codes properly that has
> both at header and a repeat section.? LG uses header length of 34 and then a
> very short repeat section of length two.? Yamaha is similar.
>
> Basically what you need to do is generate 2 IR codes each for functions like
> vol+, vol-, up, down, left, and right.? For example, for up you will have a Up-
> Pulse and a Up-Hold. For the Up-Pulse, you will remove the repeat section of
> the code so it? just sends out a single 34 length header IR pulse.? For the
> Up_Hold, you will take the 34 length header and replace the repeat section with
> it -- so in the end you have a 0 length header and a 34 length repeat section
> which used to be the header. Then in your SIMPL program send the header pulse
> when the client pushes a button.? If the client holds the button, then send out
> the repeat code.
>
> Probably be best to use a program like VERT to convert Crestron codes into
> standard hex codes.? Then manually edit the hex codes and then import them back
> into Crestron.
>
> Good luck,
> Steve







Re: IR control thru DM RMC Weirdness

 

Geoff Reynolds wrote an IR utility several years ago, that could easily swap the one-time and repeat codes, in addition to a few other useful functions.

I no longer have the link, but maybe he'll chime in with it.

--- On Monday, February 20, 2023 at 6:35 PM, Steve Kuehn wrote:

Yes this is a well known problem with the DM-RMC-100-C and I don't believe
Crestron has ever come up with a fix for it.

The issue is the DM-RMC-100-C does not handle an IR codes properly that has
both at header and a repeat section. LG uses header length of 34 and then a
very short repeat section of length two. Yamaha is similar.

Basically what you need to do is generate 2 IR codes each for functions like
vol+, vol-, up, down, left, and right. For example, for up you will have a Up-
Pulse and a Up-Hold. For the Up-Pulse, you will remove the repeat section of
the code so it just sends out a single 34 length header IR pulse. For the
Up_Hold, you will take the 34 length header and replace the repeat section with
it -- so in the end you have a 0 length header and a 34 length repeat section
which used to be the header. Then in your SIMPL program send the header pulse
when the client pushes a button. If the client holds the button, then send out
the repeat code.

Probably be best to use a program like VERT to convert Crestron codes into
standard hex codes. Then manually edit the hex codes and then import them back
into Crestron.

Good luck,
Steve


Re: IP Table Offline #simplwindows

 

FYI, for Crestron IP-controlled products, the Hardware device/IP connection uses only the IP-ID. The connection ip address is a loopback: 127.0.0.1 (except for a few maddening quasi-Crestron devices)
In fact you can't change this...
When using non-Crestron devices with for ex: the TCP/IP client symbol, you will need to add a specific IP address (or host name, though I don't recommend this) so that the processor knows who to talk to...


Re: IP Table Offline #simplwindows

 
Edited

When you create your SIMPL program, you'll define the various devices within the program. Each is assigned to an IPID. When you compile and load your code, the IP Table is automatically configured on the processor, based on your program. There's an option when loading to let the program update the IP Table, so make sure you allow that. So now, your processor knows what connections to expect (touchpanels and other Crestron devices, including Crestron Connected devices), and what connections to initiate (like TCP/IP connections to other controlled devices). For connections the processor is expecting, you'll need to set your touchpanels (for example) to use the same IPID you defined for them in the program, and point them at your processor's IP address. The touchpanel will initiate the connection, and when the processor sees a device connect on that IPID, it'll say "ah, I've been expecting you, and I know you're a touchpanel, and I'm already programmed to know what to do with each join number I might see from you."

--
Josh Winn
The LiquidPixel Group


Re: Sonos Unhandled Exception

 

Mmmm...Interesting!? We have 1052's (and 752's) and we've been having real issues with the 1052's - we just factory defaulted them!!? lets see...
Thanks for your input!!


Re: Sonos Unhandled Exception

 

From the error it looks like it's choking on data being sent from the media app to the sonos module, so I don't think it's related to S1/S2.

Maybe a touch panel is dropping offline with the media app open?


Re: TSR-310 Reset?

 

Hi Jason,
It would probably be better to start a separate thread for your questions, as I think they are more basic that this one has become, it might help others as well...
That said, the need to learn some of the fundamentals (like navigating Toolbox) is critical for someone who is going to manage Crestron systems, especially custom systems vs. Crestron Home, but even that as well...
I'd say basic training is probably not appropriate for this forum, though certainly basic questions are always welcome!!

Feel free to reach out to me if I can be of assistance


Re: TSR-310 Reset?

 

Hi guys, I'm new to Crestron and learning as I go, so go easy on me please! I am having problems with a new TSR-310 and getting it connected to my main WiFi network, so I searched and found this thread and figured I'd add to it instead of creating a new thread, if I should create a new thread just let me know.

I can't get my primary WiFi network to display so I can connect to it, it displays my guest network and I've connected to that, but my system is on my primary and so it can't find the system when on the guest network. I do have access to Toolbox, although I really have no idea how to use it, so I fumble through learning as I go, but I can't seem to connect to the remote with a USB cable. I followed the above instructions to reset the remote and I thought it did, but when it rebooted it still had my guest WiFi network locked in and connected, so I don't think it fully rebooted.

Can somebody please offer some guidance and help as to what I should try to do next to get this connected to my primary WiFi network? This looks to be a great remote but right now it's just a great paperweight, lol! Thanks!


Re: AnyCon Camera DVR/NVR recorders

 
Edited

Yes we work only with Avycon and Axis for several years now since I've tried to steer us away from Hik and Dahua.

The control is limited tho. There is no API, that comes directly from Alfred who is an engineer there who gives the best and most advanced support to us from time to time.?

Since we don't use external control for these, I'm sorry I don't have more relevant info...... But I would say that their onvif support is solid and if you are simply controlling cameras, not playback, you should absolutely try sending IP onvif commands directly to the cameras not the nvr.

Beyond that, ask for Alfred ..? and if you do get any updated NVR control please let me know !

C


Sonos Unhandled Exception

 

Hi All,
I'm seeing this Error Pair continuously on a site with an older Sonos Connect that is still on the 'S1' platform. It seems to work fine for the client, but I'm concerned that it will become an issue.
Is this anything that stands out to anyone as something specific, or could it be just the S1 legacy not playing nice with the v3.1.0 module?? I haven't integrated with S1 units for a few years...
I see that there's a v3.1.1 module, but the release note just indicates a change to some labeling in the S# side...

Anyone have any ideas??? TIA!

Error: splusmanagerapp.exe [App 2] # 2023-02-19 13:38:25? # Module S-4.1:S-1.1 : Sonos_Device_Engine_v3_1_0 at line 511: Unhandled Exception: System.Exception: Continue or End flag (E or E) not found
? ?at Crestron.CRPC.JoinTransportServerBase.OnJoinData(String pkt)
? ?at CRPCConnectionHelper.CRPCConnection.OnJoError: splusmanagerapp.exe [App 2] # 2023-02-19 13:38:25? # Module S-4.1:S-1.1 : Sonos_Device_Engine_v3_1_0 at line 511: Unhandled Exception: System.Exception: Continue or End flag (E or E) not found
? ?at Crestron.CRPC.JoinTransportServerBase.OnJoinData(String pkt)
? ?at CRPCConnectionHelper.CRPCConnection.OnJoError: splusmanagerapp.exe [App 2] # 2023-02-19 13:38:25? # inData(String packet)
? ?at SonosLibrary.SimplPlusInterfaces.Impl.MediaPlayerDeviceSimplPlusInterface.MessageIn(String pkt)
? ?at CrestronModule_SONOS_DEVICE_ENGINE_V3_1_0.CrestronModuleClass_SONOS_DEVICE_ENGINE_V3_1_0.FROM_MEDIA_PLAYER_OnChange_32(ObjeError: splusmanagerapp.exe [App 2] # 2023-02-19 13:38:25? # inData(String packet)
? ?at SonosLibrary.SimplPlusInterfaces.Impl.MediaPlayerDeviceSimplPlusInterface.MessageIn(String pkt)
? ?at CrestronModule_SONOS_DEVICE_ENGINE_V3_1_0.CrestronModuleClass_SONOS_DEVICE_ENGINE_V3_1_0.FROM_MEDIA_PLAYER_OnChange_32(ObjeError: splusmanagerapp.exe [App 2] # 2023-02-19 13:38:25? # ct __EventInfo__)
? ?at Amib.Threading.Internal.WorkItem.n()
? ?at Amib.Threading.Internal.WorkItem.Execute()
? ?at Amib.Threading.SmartThreadPool.f(WorkItem A_0)
? ?at Amib.Threading.SmartThreadPool.r()
?
Error: splusmanagerapp.exe [App 2] # 2023-02-19 13:38:25? # ct __EventInfo__)
? ?at Amib.Threading.Internal.WorkItem.n()
? ?at Amib.Threading.Internal.WorkItem.Execute()
? ?at Amib.Threading.SmartThreadPool.f(WorkItem A_0)
? ?at Amib.Threading.SmartThreadPool.r()


Re: TST-902 over wifi connection keeps disconnecting. #tst902

 

I forgot to mention that the WAPs are currently configured to be in 'access point mode'
- our network switch connects to the 'in' port on the WAP

Previously they were not set to 'access point mode' and they experienced the same problem.? Switching to 'access point mode' was a possible solution.


TST-902 over wifi connection keeps disconnecting. #tst902

 

Hey,? I have a building with 3 independent rooms.? Each room has a VC-4, a TST-902 and a wireless AP.? The GWEXERs are backordered, so we used wireless routers for connecting to the VC-4s.? The 902s have been setup to be wiif only, and have the master IPs set.? The VC-4s are running separate SIMPL programs, with the 902 wifi only version (different device IDs per program).

The 902s will occasionally disconnect from the VC-4, and sometimes even drop from the network.? The disconnects are intermittent.? I've also experienced the screen going black while I'm actively pressing buttons.? Sometimes the 902s will go for hours without issue, sometimes it's multiple times per minute.? Pushing a new or updated program file, or rebooting the 902 seems to help for a bit.? Wifi range is not an issue, one 902 is located 15ft from the WAP and still had issues.

I've spent countless hours working on this, and working with Crestron tech support.? Our setup is basically their testing ground, they're confused on what's happening and they all have different theories.? I was told they're monitoring our setup to use for future troubleshooting.

Here are some troubleshooting steps we've taken:
- put all devices on static
- put all devices on dhcp
- enable csauthentication
- disable csauthentication
- changed the 902 gateway to the VC-4 IP
- firmware updates across the board
- changed device IDs
- changed access points
- set access point to "preferred"
- increased standby timeouts
- tried using default dhcp dns and google dns?
- placed the 902 extremely close to the WAP to see if range was an issue.

Currently they're all set to dhcp.? 1 of them has csauthentication off and the other 2 have it turned on (tech support is testing to see which is more stable).

Has anyone else had similar issues?? Or does anyone have any ideas?? Our brains are shot!? Thanks in advance.


Re: AnyCon Camera DVR/NVR recorders

 

Interesting, Lincoln! thanks, I chase this...


Re: DGE100 browser and touchpanel wake

 

I have done this for a dedicated browser only TSW as well as a panel that is just for the Sonos app. Once the panel boots up it goes right into the desired application. You can just have a blank first page, and under Transition Complete Digital Join just use the reserved join needed- for Open Browser it would be 28600. That way then the page is drawn it fires that join and opens the browser. If you add the browser embedded app to that page you can specify the File- Default Path which would be the browser home page.??


Re: D3 Multiple loads grouped as one

 

What are you using to "show" the D3 loads? Are you using a Simpl program to interface with D3 or are you using the UI generated from within D3 to a iPad or touch panel? If the latter, then you can edit the VTP from within D3 and on your buttons to control you can add the other lights to that button. At least last time I used D3 for generating a UI you used to be able to do that.?


Re: IR control thru DM RMC Weirdness

 





Get
On Feb 20, 2023, at 6:34 PM, Steve Kuehn <steve@...> wrote:

Wow!? I am shock that this is the first time you have ever seen this issue.? Yes this is a well known problem with the DM-RMC-100-C and I don't believe Crestron has ever come up with a fix for it.

The issue is the DM-RMC-100-C does not handle an IR codes properly that has both at header and a repeat section.??? LG uses header length of 34 and then a very short repeat section of length two.? Yamaha is similar.

Basically what you need to do is generate 2 IR codes each for functions like vol+, vol-, up, down, left, and right.? For example, for up you will have a Up-Pulse and a Up-Hold. For the Up-Pulse, you will remove the repeat section of the code so it? just sends out a single 34 length header IR pulse.? For the Up_Hold, you will take the 34 length header and replace the repeat section with it -- so in the end you have a 0 length header and a 34 length repeat section which used to be the header. Then in your SIMPL program send the header pulse when the client pushes a button.? If the client holds the button, then send out the repeat code.

Probably be best to use a program like VERT to convert Crestron codes into standard hex codes.? Then manually edit the hex codes and then import them back into Crestron.

Good luck,
Steve


Re: AnyCon Camera DVR/NVR recorders

 

¿ªÔÆÌåÓý

From Google I suspect you mean Avycon instead of AnyCon¡­ anyway, from what I¡¯ve noticed a healthy proportion of the better the ¡°random brand¡± NVRs are either Hikvision or Dahua OEM under the hood ¨C which may be a significant compliance concern if the client has contractual relationships with the US government or their first tier contractors, but I digress.

?

A lot of times the MAC will give the OEM away if you can get to that, or comparing pictures of back panels will confirm the suspicion (there¡¯s a lot more customization in front panels it seem ¨C probably because it just takes a quick plastic mold ¨C but back panels tend to maintain some family signatures) note that you might not find an exact match because Hikvision, at least, seems to heavily segment regionally so it¡¯s possible to find an ¡°QWE¡± brand device in North America where the Hik model it is based on is only available in China or the EU or ¡­

?

?

Lincoln

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of ckangis
Sent: Monday, February 20, 2023 4:28 PM
To: [email protected]
Subject: [crestron] AnyCon Camera DVR/NVR recorders

?

Hi All,
A dealer I work for has upgraded their older Digital Watchdog camera DVR which we had doing what we needed for control via IR.
They have changed this to an AnyCon?AVR-NT532C 32-ch DVR.?
I have never even heard of this product line. Tech support is very nice, but has no idea who Crestron is (no surprise). they've sent me an IR codes doc that is limited in both explanation and command set.

Any chance any of you have even heard of this, or better dealt with them??
TIA


AnyCon Camera DVR/NVR recorders

 

Hi All,
A dealer I work for has upgraded their older Digital Watchdog camera DVR which we had doing what we needed for control via IR.
They have changed this to an AnyCon?AVR-NT532C 32-ch DVR.?
I have never even heard of this product line. Tech support is very nice, but has no idea who Crestron is (no surprise). they've sent me an IR codes doc that is limited in both explanation and command set.

Any chance any of you have even heard of this, or better dealt with them??
TIA