Re: USB Connection in Parallels on ARM MAC

 

Hey Hadley

I'm curious to learn more about how you set up your system to use Mac Terminal to work as a console through the USB RNDIS connection to a 4 series processor.? I'm familiar how to open up an SSH session with a processor and work that way, but using the USB connection from time to time is necessary from time to time.? What RNDIS driver did you use?? Anything else I should look for or know?? Thanks!


Re: CHV-TSTAT Cresnet Issue

 

If the Cresnet cable is only landed on the Cresnet connector, and they are properly assigned on both ends, I would say that there is an issue with your cable (nail or mouse chew causing a short) or something with the TStat Cresnet chip.
I would verify that there are no shorts on the cable and check all of your other connections.?
This vintage of Crestron Hardware (CHV) has been about as rock-solid as any product I have ever dealt with...


Re: CHV-TSTAT Cresnet Issue

 

Thank you both for the input.?

Disconnecting the 24v from the Cresnet wire lets the processor boot but the TSTAT is not discoverable then in CH.?

I have the jumper in the top position and R -> RH, W-> W1 & C -> 24(C). Thermostat works fine. Even if I disconnect all the other wires, simply plugging it into cresnet 4 wire trips the processor.?


Re: CHV-TSTAT Cresnet Issue

 

That depends...
If you're powering the TStat with the HVAC system, make sure that you have the 3-position jumper to the top or bottom position depending on whether you're using the RH or RC for the HVAC power and you will use the 24(C) terminal from the HVAC common. With this, You WILL USE (and MUST USE) the +24 DC from the Cresnet to power the Cresnet Communication terminals. I don't believe it will work otherwise.

In the above scenario, if you have the 3-position jumper in the Middle position ("Use ext. 24v supply) you are combining the Cresnet 24/G DC with the HVAC 24 AC Common....? The processor no likey!!...:)

In rare instances (I have one site in 20+ years), you'll not be able to reliably use the HVAC power for the Stats. in this case you can jump 24/G DC from the Cresnet connector to the 24(R) and 24(C) connectors and set the 3-position jumper to the middle position.


Re: CHV-TSTAT Cresnet Issue

 

Hi, please use 3 wires of Cresnet i.e (Y, Z, and Groud) and don't connect the +24V.


CHV-TSTAT Cresnet Issue

 

Hi All,

Having a strange issue with a CHV-TSTAT. ?Every time I connect it to the processor via cresnet, it reboots the processor constantly in 1-2 second intervals. ?Processor just blinks the green PWR button over and over. ?I've triple checked the wiring, even redone it to be on the safe side. ?The TSTAT itself actually turns on (powered from the HVAC unit) and works perfectly fine. ?Tried it with two different processors, CP4R and CP3, same behavior. ?Any ideas?

Thanks in advance.


Re: Crestron Home

 

That¡¯s one of the best parts of how Crestron implements the dual ports on the NAX.
By default, port 1 is the discovery/control port, and port 2 is the AES67 streaming port.
CH will discover it on the main VLAN while the NVX/NAX can stream on the AV VLAN.
Just don¡¯t plug in both ports until you have them configured for dual mode.

Also, the control port is where AirPlay lives, so that should be on your client VLAN.

Good Luck,
Brian


Re: Crestron Home

 

In answer to your question, yes we have successfully setup a Crestron Home system with NAX and Sonos on the same network.? While another member of our team set up Crestron Home, I did setup the network configuration.? The DM-NAX requires requires your switches be setup for IGMP snooping just like the DM-NVX.

I doubt that you could put either Sonos and/or NAX on a separate VLAN without doing some fancy network configuration mainly because Crestron Home normally cannot discover devices on other subnets.


Mark Wrote:Has anyone successfully setup a Crestron Home system with NAX and Sonos on the network? Running into issues, seemingly revolving around multicast, with NAX and Sonos being on the same Network/VLAN.


Re: Crestron Home

 

I had a similar issue - got around it via separate VLANs and firewall rules to limit the multicast traffic from overwhelming the network.?

On Fri, Dec 8, 2023 at 15:23 Mark via <mark.rubin=[email protected]> wrote:
Has anyone successfully setup a Crestron Home system with NAX and Sonos on the network? Running into issues, seemingly revolving around multicast, with NAX and Sonos being on the same Network/VLAN.


Re: Crestron Home

 

Would that not just flood network as well?

I should have mentioned, for this site, they are using the Araknis AN210SWR24POE switch.


Re: Crestron Home

 

It's best to use a secondary unmanaged switch for the Sonos.??


On Fri, Dec 8, 2023, 1:23?PM Mark via <mark.rubin=[email protected]> wrote:
Has anyone successfully setup a Crestron Home system with NAX and Sonos on the network? Running into issues, seemingly revolving around multicast, with NAX and Sonos being on the same Network/VLAN.


Crestron Home

 

Has anyone successfully setup a Crestron Home system with NAX and Sonos on the network? Running into issues, seemingly revolving around multicast, with NAX and Sonos being on the same Network/VLAN.


Re: Module Poly G7500

 

Hello, is it possible to have a copy of the poly G7500 module you used.....Thanks in advance


Re: Construct Headaches

 

I played with Construct for about an hour.? My main takeaway was "time to knock the dust off my HTML/CSS skills" and went down that avenue instead, although Crestron has issues there as well (specifically with their default template).? ??
??
? It's like Studio if tried to be a WYSIWYG HTML editor.? Has that same half baked feeling as Studio.


Re: HZ-THStat

 

I love this group!!!

BTW, I have already programmed/tested the User interface and that is the only part that I'm not concerned about...(Who knew!!)...
Though, As with every updated generation of Crestron devices, it would be nice if they kept to same/similar SMW interface and just added what they needed...


Re: Just add power module errors

 

There's some misinformation there. The long integer to integer warning is a genuine warning that you may be losing data due to downcasting from 32 to 16 bits. Whilst it's never normallly an "issue" persay, it can be rectified by casting the assignment. Casting in Simpl+ is done by surrounding the long with brackets, for example:


LONG_INTEGER myLongInt;
INTEGER myNormalInt;

myNormalInt = (myLongInt);

The #SYMBOL error is telling you that the 2 AVSwitch modules are symbol named as V3_04. #SYMBOL names should be unique to the file version.


Re: HZ-THStat

 

On Thu, Dec 7, 2023 at 03:08 PM, XSDS wrote:
1. Who designed these things?? clearly no one who has installed them or had to take one off its base to service it!!!
Seriously!! We were already planning to use retro back-boxes but I can't imagine mounting these with sheet-rock anchors-The first time an HVAC guy tries to remove it on a Saturday when he's trouble-shooting a No-Heat call from the client he would rip out half the wall!!!? I'm mean, is Crestron really concerned that a 'press-fit' mounting like the old CHV units would not hold this thing on??
NOTE: Though I found no info in the manuals (Ha!) and tech support had no idea as to the *Best Practice* for removing one after it is LOCKED onto its sub-base, we did figure out that if you put a tweeker at a 45 degree angle into the slots at the bottom right corner, you can use this to leverage on the back plate to pull that corner of the stat off its detent. then the tweeker can be used to pop off another detent and the unit comes off...Like I said, the uninitiated will be damaging something I'm sure....
Could not agree more.? Please have the engineer who did the industrial design retrofit 10 of these in a project and wire 5 of them with a 2 stage heat, 2 stage cool, with floor warming and a remote temp sensor and then ask him if he thinks he designed an installer friendly piece of hardware.

--Mounting options--
FAIL - base plate mounting holes too close to the margin of the drywall opening
Self drilling drywall anchors
Mollys
Plastic anchors
Toggles

MAYBE
Retro ring with wings - stat slightly proud of the wall depending on the make of the ring
Retro Carlon box with wings - have to "dado" the drywall paper and some plaster to get the stat to sit flush on the wall

WORKS
SG LV ring mounted horizontally
SG 4-square plaster ring mounted horizontally
Carlon SC100A (my favorite) -?

Jim Felderman

ControlWorks Consulting, LLC

Crestron Services Provider


Re: HZ-THStat

 

On Thu, Dec 7, 2023 at 03:08 PM, XSDS wrote:
Bonus/Easter Egg:
On the same project we have (8) HR-310s... Two of them are being advance replaced OOTB
One would *crash* whenever I tried to put it in acquire mode...
The crashing while trying to acquire I have seen in the field and in my case it was always due to the remote shipping with old FW.? I updated the FW to release and that issue went away.? Also for those who missed it in the release notes I should mention that you can change the RFID on an acquired 310 via the numpad and top hard buttons mapped to A-F.? Nice add.

Jim Felderman

ControlWorks Consulting, LLC

Crestron Services Provider


Re: Concord 4 Control

 

Yes, you can set the alarm via RS232, I do it every night. There is a keypad simulator, it works just like the panel keypad.


Re: HZ-THStat

Michael S Moran
 

¿ªÔÆÌåÓý

With respect to mounting and future service needs/requirements, we typically utilize a mud ring or back box, horizontally

Deployed/mounted.?

?

As an alternate approach, use an auger screw-type fixing anchor.? These devils have a far greater resistance

from being pulled out of drywall that is in relatively good condition¡­not damp or wet.?

?

Respectfully,

?

Michael? S. Moran

?

?

?? Office:? 561.391.1843

?

?

?

?

From: [email protected] <[email protected]> On Behalf Of XSDS
Sent: Thursday, December 7, 2023 3:08 PM
To: [email protected]
Subject: Re: [crestron] HZ-THStat

?

On Thu, Dec 7, 2023 at 02:56 PM, ckangis wrote:

So as not to keep my ardent fans waiting, I thought that rather than wait until the end, I'd post individual updates...:)

Today I started to *bench* the (7) units to get them ready - Wifi connect, FW, IP-ID, IP address...? Found two items:

1. Who designed these things?? clearly no one who has installed them or had to take one off its base to service it!!!
Seriously!! We were already planning to use retro back-boxes but I can't imagine mounting these with sheet-rock anchors-The first time an HVAC guy tries to remove it on a Saturday when he's trouble-shooting a No-Heat call from the client he would rip out half the wall!!!? I'm mean, is Crestron really concerned that a 'press-fit' mounting like the old CHV units would not hold this thing on??
NOTE: Though I found no info in the manuals (Ha!) and tech support had no idea as to the *Best Practice* for removing one after it is LOCKED onto its sub-base, we did figure out that if you put a tweeker at a 45 degree angle into the slots at the bottom right corner, you can use this to leverage on the back plate to pull that corner of the stat off its detent. then the tweeker can be used to pop off another detent and the unit comes off...Like I said, the uninitiated will be damaging something I'm sure....

2. Wifi Connection...
Yes, I set up a dedicated 2.4g SSID for the stats (See TStat website/Specs/Communications).? Four of the Stats connected and were able to be set up with reasonable ease apart from the really long reboot and file transfer times.
The other three stats would never see their SSID though they would routinely see the client's main and guess SSIDs and of course the ad-hoc SSID from the crappy HP ENVY printer sitting next to me - So I guess I could get the TStats to print...:)
Support and I tried a bunch of things including setting our special SSID to both 2.4 and 5g like the client SSIDs and doing Factory Resets but they would not see this SSID.
Result: Crestron is advance replacing 3 of 7 TStats...?? ?We'll see on the next round...

Bonus/Easter Egg:
On the same project we have (8) HR-310s... Two of them are being advance replaced OOTB
One would *crash* whenever I tried to put it in acquire mode...
And the other one was physically missing 2 of the 6 battery terminals...YES PHYICALLY MISSING 2 OF THE 6 BATTERY TERMINALS....WTbleep!!

Hope you all enjoyed this first message!? Love you all...:)


?Gonna be a lot longer list than this shortly!? Wait till you get to the programming part.