Re: Crestron App
Also check TIMEDATE / TIMEZ / SNTP settings on the PRO3 to ensure the time & date match the mobile device. If the PRO3 has AUTH+SSL ON (and SSL was enabled in CGo/CApp w/ the auth creds entered), then
By
Dave H - Crestron True Blue Tech Support Engineer Since 2014
·
#246130
·
|
Re: Alert! concerning the PC-350V power controllers
Yes, My initial tests show that things are good now...However, the nature of this issue (Floating Neutral, etc) is intermittent so I will report if any other problems occur. And of course I would hope
By
ckangis
·
#246129
·
|
Re: Crestron Home BACnet HVAC
Thanks for the tips, I've been looking at other BNE, yabe reports fine with Coolinkbridge ID64 with firmware 0.3.4 but nothing with new devices we have 3 off with firmware 0.3.8, just noticed this
By
Mark G
·
#246128
·
|
Re: LG Display IP Control WOL
Just wanted to share that I've discovered that Wired Wake On LAN can be changed without the remote control by sending the "fw id data" command, where data is 00(Off) or 01(On). For example, "fw 01
By
Savva
·
#246127
·
|
Re: Alert! concerning the PC-350V power controllers
So, going on UPS power worked now?
By
Michael Fletcher
·
#246126
·
|
Re: Alert! concerning the PC-350V power controllers
Just a follow-up. Today I updated my PC-350V's with the latest/new FW to resolve (Hopefully!) the issue noted in this thread. Obviously its too early to tell how things will go, but initial tests seem
By
ckangis
·
#246125
·
|
Re: Crestron App
also check on the iPad settings, scroll down to Crestron Go, make sure "use local network" is switched ON.
By
Michael Block
·
#246124
·
|
DM-NVX-E30 / D30 and Dolby Atmos
I have been unable to get Dolby Atmos to work from an Apple TV using NVX encoders / decoders.? Just updated NVX firmware to 7.0.? I've tested with both a McIntosh MX-180 and a Yamaha CX-A5200
By
plareeeiybusse
·
#246123
·
|
Re: Crestron Home BACnet HVAC
I had some issues with YABE, only one CMNgw at id 64, but yet not discovering, etc. I tried with also with BDT (bacnet discovery tool), and it reported the units fine. It didn't report the information
By
Martin Szmulewicz
·
#246121
·
|
Re: Crestron App
If authentication was enabled in the PRO3, check if IP got blocked. 'Remblockedip'
By
ZS
·
#246120
·
|
Crestron App
Greetings all .I had an app project working fine .it was local only .suddenly stopped. Says connection refused .I have updated firmware , all data bases still says the same .any ideas ? Its on a pro3
By
wartyhogus
·
#246119
·
|
Re: VS 2008 Can't Open Crestron Projects
Microsoft released an update which should fix the issue: 2022-05 Cumulative Update for .NET Framework 3.5 and 4.8 for Windows 11 for x64 (KB5013628) -- Crestron Service Provider - TBD Enterprises Inc.
By
Troy Garner
·
#246118
·
|
Re: CCDs and NVRAM
SIMPL+ NVRAM allocation was introduced in CCD Disp Eth v1.14. (F1 Revision History calls out "Added ability to page through more than 10 user attributes.") SIMPL compiler calls out max NVRAM
By
Dave H - Crestron True Blue Tech Support Engineer Since 2014
·
#246117
·
Edited
|
Re: CCDs and NVRAM
Well must be a hold over from 2 series in Simpl, crisis averted.? I checked the PRO4 and it actually has 3MB of NVRAM.
By
John Gabler
·
#246116
·
|
Re: QSX Keypad Buttons Presses
Hi there! You would use the feedback signals of the?Lutron HomeWorks QSX Button Control v1.1 module. The outputs of that module will go high when the corresponding physical Lutron keypad button is
By
@MikeSpadafora
·
#246115
·
|
CCDs and NVRAM
Learned a valuable less today.? I am using the Sony IP CCD modules for both TV and Receivers.? Apparently they are NVRAM hungry.? Each CCD allocates about 10KB of NVRAM.? I am just updating a
By
John Gabler
·
#246114
·
Edited
|
Re: Wake On LAN (WOL) Help!
Thanks for all the advice and suggestions! I ended up doing what Dave H suggested (one of his suggestions) and made my magic packet string in Notepad and copied/pasted into an SIO. I had to put a 1 on
By
David H
·
#246113
·
|
Crestron Home BACnet HVAC
Cool automation and Crestron Home BACnet, YABE We have 1 CoolinkBridge ID 64 showing a HVAC system detailed BACnet data for Thermostat - operation is good in Crestron home? YABE show all BACnet info
By
Mark G
·
#246112
·
|
Re: Wireless radiator valves (UK project)
I should also add that the Shelly TRV can be fully controlled through the Shelly app. Thanks Jay [email protected]> wrote:
By
jbasen
·
#246111
·
|
Re: Wireless radiator valves (UK project)
Correct. All Shelly devices communicate directly over WiFi so they don¡¯t require a hub And, the Shelly drivers I¡¯ve written will run on either a 3 or 4 series processor. All the source code is
By
jbasen
·