Re: RMS with ARDOP
My ARDOP port. PORT PORTNUM=7 ID=ARDOP DRIVER=ARDOP INTERLOCK=1 CONFIG ADDR 127.0.0.1 9515 ;custom port DEBUGLOG TRUE CMDTRACE TRUE CWID FALSE DRIVELEVEL 100 BUSYWAIT 20 MAXCONREQ 10 GRIDSQUARE GG87EA
By
Mauro Veiga
·
#41803
·
|
Re: RMS with ARDOP
Maybe if you posted your ARDOP Port configuration? Did you follow the example in the BPQ documentation?
By
Mark Taylor
·
#41802
·
|
Re: BPQ32.CFG Help required.
Oops.. Make the applications... APPLICATION 1,BBS,,GB7NFD-1,NFDBBS,255 APPLICATION 2,CHAT,,GB7NFD-4,NFDCHT,255
By
Mark Taylor
·
#41801
·
|
Re: BPQ32.CFG Help required.
Ok, did find something else... You are defining your node alias as NFDBBS. So, connecting to NFDBBS connects you to your node. Try these and restart... NODECALL=GB7NFD NODEALIAS=NFDNOD APPLICATION
By
Mark Taylor
·
#41800
·
|
Re: RMS with ARDOP
Hello Mark. I created an ARDOP port, but I can't access the Node/BBS or RMS through it. I did local tests with ARDOP Chat and the modems connect but I can't browse the Node or BBS, the BPQ doesn't
By
Mauro Veiga
·
#41799
·
|
Re: BPQ32.CFG Help required.
Not a reason for affecting your connections, but, there is normally no reason to be listening on two different UDP ports. What is your reason for that? Also, there is BTINTERVAL defined twice. Doesn't
By
Mark Taylor
·
#41798
·
|
Re: BPQ32.CFG Help required.
I connected to your node. Browsed your node. Connected to your node. Returned to your BBS Started a message to you. When ending the message your BBS stopped responding. I am assuming because your have
By
Mark Taylor
·
#41797
·
|
Re: BPQ32.CFG Help required.
You now have LINMAIL and LINCHAT duplicated in the config. Could it be that you have two instances of each started? Can you be more specific with what mode and connect to what, etc? Telnet is
By
Mark Taylor
·
#41796
·
|
Re: RMS with ARDOP
Yes, simply create an ardop port. If it shares a radio with the Vara HF port you will need to Interlock them with the same number. Make sure the port responds to any incoming winlink connections and
By
Mark Taylor
·
#41795
·
|
BPQ32.CFG Help required.
Hi All, I am still having trouble can anybody tell me if anything is missing from my BPQ32.cfg file as people are having trouble connecting, but everything works from a telnet connection Adrian de
By
Adrian Lane
·
#41794
·
|
RMS with ARDOP
Hi folks. My Winlink Gateway works fine with Packet and VARA HF but not with ARDOP. Is possible to setup BPQ32 to work RMS with ARDOP? TIA
By
Mauro Veiga
·
#41793
·
|
Re: Adding Users to BBS
Hi John, I fully understand now, using the default callsign for the node/bbs and the Sysop password got me in fine. Regards Adrian de 2e0sdr
By
Adrian Lane
·
#41792
·
|
Re: Adding Users to BBS
How are you adding a user? Is it via the Web interface? Login to the BBS Management Web pages uses the user/password in the Telnet Config. (SYSOP status is needed). If you access from a browser on the
By
John G8BPQ
·
#41791
·
|
Adding Users to BBS
When I go into add a user to the BBS, it simply throws me out to a login and does not accept any login info I enter. I also cannot login to Webmail. I was wondering if anybody could tell me how to add
By
Adrian Lane
·
#41790
·
|
Re: BBS Not working
A few comments. SIMPLE is primarily intended for use on systems without NETROM. Although I often use it from laziness I think it is better to explicitly set all the parameters, particularly when you
By
John G8BPQ
·
#41789
·
|
Re: BBS Not working
Hi Chuck, Thanks for that, I have updated the BPQ32.cfg accordingly. Much appreciated. Adrian de 2e0sdr
By
Adrian Lane
·
#41788
·
|
Re: BBS Not working
+1 with Mark. Especially no NETROM on HF. However, 'salt to taste'. I think QUALITY should be larger than MINQUAL. A QUALITY difference of +/- 10 or less might be sufficient to get the results you
By
Chuck Gelm
·
#41787
·
|
Re: BBS Not working
Cheers Mark
By
Adrian Lane
·
#41786
·
|
Re: BBS Not working
Many thanks John.
By
Adrian Lane
·
#41785
·
|
Re: Digipeater Setup Question
[email protected]> wrote: The method
By
Lee Bengston
·
#41784
·
|