Welcome to the YaMoRC/Digikeijs English Forum
?
This Table of contents provides information about the YaMoRC and Digikeijs products in US English and JMRI.
Click on the "Read More" to see all the information.
Legal notice:
All instructions are written to the best of our knowledge and belief of the respective authors.
Nevertheless, no liability for any errors or omission in the Documentation is intentional!
?
General:
The Main website of the manufacturers YaMoRC and Digikeijs can be reached via the following link:
- Link to the
- YaMoRC Support for Documents. TBD
- Link to the Digikeijs Firmware:?The latest firmware for each product will be in its respect file directory if we have the latest firmware.
- This is an archive that was made and will have documents in other languages. Check before you download.
?
US Dealers:
- for YaMoRC and Digikeijs Products.
Click on any RED Model number below, it will send you to the files page for that device.
English Only Manuals and Photos, etc can be found on this Forum and elsewhere:
Central Station:
- DR5000 The first Command Station with all conceivable connection sockets and LED status lights, USB, LAN & WLAN
- Detailed Tutorial - Rudy's Model Railway Videos on DR5000
Booster:
- DR5033 3 amp Booster works with many different Command Stations
Switch and Servo Modules:
- DK50018 16 Channel Bluetooth accessory and switching decoder
- DR4018 16 Channel Multi-Protocol Switching Decoder
- Manual: DR4018 Advanced V1.2
- Video Series for the DR4018 or DK50018 on Preset 1 in JMRI to invert the outputs for LED Signals.
-
- Guide for Testing the DR4018/DK50018 for proper Preset Configuration.?
- DR4024 4-output multi-protocol servo decoder with 4 additional switching outputs
?
Feedback Modules:
- ?DR4088CS & CS-GND 16-input feedback module (S88)
?
- ?DR4088LN-CS, LN-GND & LN-OPTO 16-input feedback module (LocoNet)
-
?
- ?DR4088RB-CS & RB-OPTO 16-input feedback module (R-Bus)
?
- ?DR5088RC 16-input feedback module with RailCom (LocoNet)
?
Reverse Loop Module
- ? DR5013
- Video :?
Turntable Module
- ??? DR5052
?
Other Equipment
- ??? DR4050 DigiLEDs RGB Model Train Light Control
?
- ??? DR5022 DigiControl for the control of 2 trains via a swivel
?
- ??? DR5039 LocoNet-B to CDE
?
- ??? DR5097 DigiNetHub 10x LocoNet Hub
?
- ??? DR5098 DigiNetHub 10x X-Bus Hub
?
- ??? DR5099 DigiNetHub 5x X-Bus Hub & 5x LocoNet Hub
Software
- JMRI
?
- RocRail
-
- ITrain
- Train Controller
- Perecli RRA (Railroad Automation)
- ?
- ?
- ?
- ?
- ?
-
- AnyRail:
Throttles:
- Document showing the Apps that work with JMRI and DR5000 with download links.
- Roco WLANmaus Throttle Setup For The Digikeijs DR5000
- Test of the Proto-Throttle with the Digikeijs DR5000
- RtDrive Lenz With The Digikeijs DR5000
- ESU Mobile Control II Throttle With The Digikeijs DR5000
- DigiTrainsPro (Android Phone) DR5000 Setup (Now a monthly fee of 5 Eros for this version)
- Z21 App for Apple or Android Phones.?
?
Other Features:
- ?
?
?
?
DR5000 - throttle apps compatible with its WiFi
I know the Z21 app works (and I've used it) but I'm not clear about other apps.
From digging around it seems apps such as WiThrottle or Engine Driver need to go through JMRI or something like a LNWI
By
Nags
·
#4787
·
|
Re: Short Circuits on Layout with several YD7403 Boosters
I suggest that the setting you want to change is the GPON/GPOFF to stop it forwarding short circuit events over LocoNet. I am not sure whether no highlight means it isn’t sent or it is sent, best to
By
Iain Morrison
·
#4786
·
|
Re: Short Circuits on Layout with several YD7403 Boosters
Thanks for responding Iain,
Did you mean the Button Action menu? It defaults to "Power On/Off Global", so could you mean "Power On/Off Local"? (I can't test that for a few days unfortunately)
The only
By
Oldngrey
·
#4785
·
|
Re: Short Circuits on Layout with several YD7403 Boosters
You need to change the options within the booster and tell it not to forward the short to the command station. You can change the actions in the track power options.
I would also feed the turnouts
By
Iain Morrison
·
#4784
·
|
Short Circuits on Layout with several YD7403 Boosters
My apologies if this has already been answered.
I have several YD7403 boosters connected via Loconet B to my YD7001 Command Station.
They work fine but I would prefer a short circuit somewhere on a
By
Oldngrey
·
#4783
·
|
Re: Z21 and s88 yd6o16es modules
any idea what the solution is.
I've tried different power supplies.
End of bus resistors from DCC concepts.
Why do they work perfectly with the ecos, but within 20 minutes coupled to the DR5000 they
By
Alan Watt
·
#4782
·
|
Re: Z21 and s88 yd6o16es modules
It happens with other systems also
Many Thanks
Iain Morrison
https://wimorrison.com/
[email protected]> wrote:
By
Iain Morrison
·
#4781
·
|
Re: Z21 and s88 yd6o16es modules
just wondering is the yd7010 much different to the DR500/YD9401
a i was thinking would using the yd7010 would solve my problem with the
cobalts losing their addresses
as this problem only occurs when
By
Alan Watt
·
#4780
·
|
Re: YD6016ES-CS N gauge current detction
As long as you motors or wagons are drawing more than 2mA the you will have
zero issues, especially given that the YD6016xx is sensitive to less than
2mA. If the wagons do not have anything drawing
By
Iain Morrison
·
#4779
·
|
YD6016ES-CS N gauge current detction
Good afternon I was wondering if anyone had an experience using the YD6016ES-CS detecting N gauge rolling stock and the reliability?
Many Thanks
By
Andrew Jebb
·
#4778
·
|
Re: YD8008 with YD6940 and Kato Unitrack turnouts
I have a Kato double crossover T-Trak module with I use a 9 volt battery to run it with a dpdt monetary switch. what you might want to try is powder graphite into the switch it self to help over come
By
James Braxton
·
#4777
·
|
Re: DR4102 Relay Alternatives
There are variations with these modules including operating voltage and trigger - many are just Lo others are either Hi or Lo by jumper. Note you need to set the trigger source jumper to use either
By
Nags
·
#4776
·
|
Re: DR4102 Relay Alternatives
Could you go into a little more detail on how you wire up those modules. I bought a 8 relay module thinking this would work, but I can't seem to figure out how to wire it given the switched output of
By
Rich
·
#4775
·
|
Re: DR5000 with installed YD9401 upgrade. WWW server doesn't work, stuck until power off / power on
#DR5000
#YD9401
Not use it, see the answer to your ticket !!
By
karst.drenth
·
#4774
·
|
DR5000 with installed YD9401 upgrade. WWW server doesn't work, stuck until power off / power on
#DR5000
#YD9401
Hello, ?I installed YD9401 to my DR5000. ?Upgraded both DR5000 side Atmel FW and YD9401 ESP32 firmware, config program version YD_Config-build-72.exe.
WWW server doesn't work. ?The first page
By
Antti Louko
·
#4773
·
|
Re: Z21 and s88 yd6o16es modules
Max 5 per YD6016LN
By
karst.drenth
·
#4771
·
|
Re: Z21 and s88 yd6o16es modules
Not certain, but you could add a second YD6016LN-CS which you connect via Loconet and split the YD6016ES-CS across the pair of them.
Sent: 07 February 2025 15:45
To:
By
Iain Morrison
·
#4770
·
|
Re: Z21 and s88 yd6o16es modules
yes but how many S88s can you put onto 1 loconet device
By
Alan Watt
·
#4769
·
|
Re: Z21 and s88 yd6o16es modules
Best bet would be to but a YD6016LN-CS and connect it to the LocoNet on the
Z21 black. You connect the ES modules into the LN Module
Many Thanks
Iain
By
Iain Morrison
·
#4768
·
|
Z21 and s88 yd6o16es modules
hello all
I'm thinking of buying a Z21 black but can I use my 12 S88s with the Z21 as they are all coupled by ethernet cables
Does the Z21 have this connection
thanks, Alan
By
Alan Watt
·
#4767
·
|