Re: Switch controller for Peco PL-11 motors
The DR4018 should operate the Peco surface mount motors but it will need configuring to Preset 0, ideally using a separate power supply which is 12v 3A DC. The DR4018 is not suitable for the PL10 or
By Iain Morrison · #3618 ·
Switch controller for Peco PL-11 motors
During one of the lockdowns I built a small n scale railway. Peco shut down for the period of the lockdown so I used Kato track and the DR4018 which drove the point motors with no problem. After some
By RobinP · #3617 ·
Re: DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
Hi All Sounds an amazing layout with a multitude of connections ALL working - well done!! One specific point You mention you have 7 DR5033 boosters linked to your command station presumably with LNet
By John Critchley · #3616 ·
Re: DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
Karst Some answers: How many WiThrottle connections did you make until now ( simultaneous ) ? * I had 8 throttles using WiThrottle simultaneously.? ?Six of the UWT-100s and UWT-50s and the two cell
By Jay Lennox · #3615 ·
Re: DK50018 working intermittently with iTrain
Cheers Iain It's now working again. Don't ask me how or why! I was running trains as normal and then the layout shorted out due to a train running through a point then iTrain wasn't recieving any
By Matt Wolstenholme · #3614 ·
Re: DK50018 working intermittently with iTrain
I very much doubt that there is any issue with iTrain. If there was then then thousands of users would have reported issues ¨C and no-one has. From what you describe the common failure point is the
By Iain Morrison · #3613 ·
Re: DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
Wow !! :O How many WiThrottle connections did you make until now ( simultaeneous ) ? You also can Use the Z21 App now that you have the YD7001 ;) And the LNWIs do work ? aka, do not interfere :)
By karst.drenth · #3612 ·
Re: DK50018 working intermittently with iTrain
Hi Iain. Thanks for the reply. Yes just checked and the correct interface is selected in the turnout definition, it is the same as the other 20 odd turnouts I have working from DR4018s which are all
By Matt Wolstenholme · #3611 ·
Re: DK50018 working intermittently with iTrain
Do you have the correct interface and/or the correct output device selected in the iTrain turnout definition? Sent: Wednesday, August 23, 2023 11:41 PM To: [email protected] Subject: YaMoRC,
By Iain Morrison · #3610 ·
DK50018 working intermittently with iTrain
Hi Has anyone come across a fault I've picked up today. I've recently installed some new track and pointwork and I'm using a DK50018 to power the MP5 point motors and set to preset 6, it has been
By Matt Wolstenholme · #3609 ·
Re: DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
Hi All Wednesday, August 23.? I did a bunch of testing at the club yesterday.? Lots of success and a few tips to report. First a TIP.? Initially I could not get a stable LAN connection established
By Jay Lennox · #3608 ·
Re: YD9401 Upgrade Tip
Karst I have an update based on testing at the club yesterday. I inserted a gigabit switch between the AC1200 router and the YD7001 and the LAN connection to the router showed no more signs of being
By Jay Lennox · #3607 ·
Re: YD9401 Upgrade Tip
Karst What is interesting is that my 20 year old router establishes a stable LAN connection with the YD7001 and the clubs router bought in 2019 cannot establish a stable connection (the connection to
By Jay Lennox · #3605 ·
Re: YD9401 Upgrade Tip
I have three questions that perhaps others who have upgraded their DR5000 to YD7001s can help me with: Some people have reporte
By karst.drenth · #3604 ·
Re: DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
Yes, mine too - if you follow the instructions found at https://www.dcctrainautomation.co.uk/user/Upgrade%20instruction%20YD9401.nl-en.pdf
By AlanRailwayMan · #3603 ·
Re: YD9401 Upgrade Tip
Hi I have three questions that perhaps others who have upgraded their DR5000 to YD7001s can help me with: * Has anyone had problems establishing a stable connection between the YD7001 LAN port and a
By Jay Lennox · #3602 ·
Re: DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
Thanks for keeping us updated. My conversion to theYD7001 went smoothly also. -- Dennis Cherry Owner/Moderator
By Dennis Cherry · #3601 ·
DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
Hi I decided to start a new topic as it will take me several weeks to complete the upgrading of our two DR5000s to YD7001s at York Railway Modellers in Toronto.? I have to make sure that I keep the
By Jay Lennox · #3600 ·
Re: Want to buy: DR4088CS or LC-CS for new layout
i may have 10 dr4088s ln for sale wrote:
By Alan Watt · #3599 ·
Re: Want to buy: DR4088CS or LC-CS for new layout
I had to ask. Track is expensive:) -- Heath @ Human[c]ity http://www.humancity.org ( http://www.humancity.org/ ) http://www.riversidetransfer.nyc ( http://www.riversidetransfer.nyc/ )
By Heath @ Human[c]ity Junction · #3598 ·