¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Re: DR5000 with installed YD9401 upgrade. WWW server doesn't work, stuck until power off / power on #DR5000 #YD9401
Not use it, see the answer to your ticket !!
By karst.drenth · #4774 ·
DR5000 with installed YD9401 upgrade. WWW server doesn't work, stuck until power off / power on #DR5000 #YD9401
Hello, ?I installed YD9401 to my DR5000. ?Upgraded both DR5000 side Atmel FW and YD9401 ESP32 firmware, config program version YD_Config-build-72.exe. WWW server doesn't work. ?The first page
By Antti Louko · #4773 ·
Re: Z21 and s88 yd6o16es modules
Max 5 per YD6016LN
By karst.drenth · #4771 ·
Re: Z21 and s88 yd6o16es modules
Not certain, but you could add a second YD6016LN-CS which you connect via Loconet and split the YD6016ES-CS across the pair of them. Sent: 07 February 2025 15:45 To:
By Iain Morrison · #4770 ·
Re: Z21 and s88 yd6o16es modules
yes but how many S88s can you put onto 1 loconet device
By Alan Watt · #4769 ·
Re: Z21 and s88 yd6o16es modules
Best bet would be to but a YD6016LN-CS and connect it to the LocoNet on the Z21 black. You connect the ES modules into the LN Module Many Thanks Iain
By Iain Morrison · #4768 ·
Z21 and s88 yd6o16es modules
hello all I'm thinking of buying a Z21 black but can I use my 12 S88s with the Z21 as they are all coupled by ethernet cables Does the Z21 have this connection thanks, Alan
By Alan Watt · #4767 ·
Re: Railcom with JMRI Reporters working on TCS CS-105 through Digikeijs DR5088RC
Whoopee.. Personally looking at 5 units to go with my 2 Digikeijs DR5088RC units...
By Tank · #4766 ·
Re: Railcom with JMRI Reporters working on TCS CS-105 through Digikeijs DR5088RC
Looking forward, need one to complete my block detection. The DR5088RC will still be used, it is working flawlessly with the bias resistors I posted earlier on the forum. Dennis Cherry
By Dennis Cherry · #4765 ·
Re: Railcom with JMRI Reporters working on TCS CS-105 through Digikeijs DR5088RC
Won¡®t take long anymore. Dev. is ready, waiting for a production slot ;) (YD6016LN-RC) greets, Karst
By karst.drenth · #4764 ·
Railcom with JMRI Reporters working on TCS CS-105 through Digikeijs DR5088RC
I was discussing RailCom and the CS-105 earlier. ?I had not seen anyone post about getting RailCom to work with JMRI Reporters through the Digikeijs DR5088RC and a RR-Circuits LCC-LocoNet Gateway on
Re: DR4088LN-CS with DR4088CS some of my sensed blocks activate with just a touch of the sensed wire
I started another thread for the double tap wheel gap activation issue. It was solved by changing the default sensor delay in JMRI. As far as I know you cannot change any detection setting related to
By Mike's DeepRun RR · #4762 ·
Re: DR4088LN-CS with DR4088CS trailing blocks turn on and off when metal wheels pass over insulated jointer
Iain Thank you for your response. As you indicated there is no where that I have found to add a delay to prevent these nuisance detections. I am using JMRI so I went to the sensor table/defaults/
By Mike's DeepRun RR · #4761 ·
Re: DR4088LN-CS with DR4088CS trailing blocks turn on and off when metal wheels pass over insulated jointer
In software other than JMRI (or feedbacks other than DR4088xx) this ¡®bouncing¡¯ can be cured by increasing the feedback switch-on delay slightly, from 0ms to 25ms, or even 50ms. This creates enough
By Iain Morrison · #4760 ·
DR4088LN-CS with DR4088CS trailing blocks turn on and off when metal wheels pass over insulated jointer
Thanks in advance. When running a train with multiple cars and a single engine the first block activate as expected when the engine enters it but then when the trailing cars with metal wheels cross
By Mike's DeepRun RR · #4759 ·
Re: YD8008 with YD6940 and Kato Unitrack turnouts
Karst Thanks for this advice I'll upgrade my PSU. Before reading your post I'd actually come to a similar conclusion that it was a power supply issue. I was originally powering two YD8116s together
By grahammjmason · #4758 ·
Re: YD8008 with YD6940 and Kato Unitrack turnouts
There lies your problem, our experience is, that the Kato's connected to the YD8008/6940 combo need 15V PSU of about 400mA minimum. Reason: Both YD8008 (1.2V) and YD6940 (0.7) introduce a voltage
By karst.drenth · #4757 ·
Re: DR4088LN-CS with DR4088CS some of my sensed blocks activate with just a touch of the sensed wire
I discovered tonight a wiring booboo. When I switched to tortoise switch machines I powered some of the frogs with straight booster power. So when the engine goes over the frog the power is not sensed
By Mike's DeepRun RR · #4756 ·
Re: YD8008 with YD6940 and Kato Unitrack turnouts
Iain I took my advice from the YaMoRC website.? It clearly states that for Kato points you need to use the YD8008 with the YD6940 to convert to 2 wire from 3 wire.? I had originally thought about
By grahammjmason · #4755 ·
Re: YD8008 with YD6940 and Kato Unitrack turnouts
Graham, I wonder if the YD8008 are the correct switches to be using with Kato turnouts. The common use for the YD8008 is power hungry solenoids such as the Peco/Seep style that need a real thump
By Iain Morrison · #4754 ·