Date
Re: 11402 knob coupling that slips
Hi Kurt, If you do make an "O" ring piece to squeeze the plastic, don't get greedy with the amount of 'squeeze' you put in to it, as you could easily crush that plastic piece that slides over the
By tom jobe <tomjobe@...> · #147844 ·
Re: 7633 readout drift
It drifts independent of the trace. Yes I have some cold spray AND a parts mule. So this should not be a huge deal.
By Brendan · #147843 ·
Re: 7633 readout drift
No, it's supposed to be in the correct position as soon as the beam appears. Does it drift with the trace, or independently? Also, do you have a cold spray? The easiest way to find out the culprit is
By davehouse@... · #147842 ·
Re: Automatic Brightness Control : was it ever implemented ??
The 2213 that I had for a short while included automatic brightness. On my machine it seemed to not work very well, perhaps it was defective (forty year old machine) so I wasn't disappointed that the
By Ted Rook · #147841 ·
Re: 7T11 sampling timebase - how does it behave?
Hi Raymond, I looked at the pix. You seem to have 30pSec risetime and I would like to know how you do that since the S4 has a 25pS rise time. That would mean you were using a 13pS pulse. The 2nd photo
By Dennis Tillman W7pF · #147840 ·
Re: Automatic Brightness Control : was it ever implemented ??
I don't know the full answer, but the nearest I can think of quickly is that some (or all?) of the 7000-series timebase plugins limit the beam current at slow sweep speeds to prevent CRT burn. That's
By cmjones01 · #147839 ·
Re: 453 calibrator
I mentioned the P6042 and A6302 in a recent message but is seems to have been lost somewhere. Both probes are long out of production. The P6042 has an interesting design and is complete i. e. does not
By Raymond Domp Frank · #147838 ·
Re: Tek 565 tubed
Yes it is unfortunate that someone took all the tubes , from what i had a was able to find some tubds , howerer not all i have a good number 6dj8 and a few other , but just not enough to complete the
By oliver johnson · #147837 ·
Re: Automatic Brightness Control : was it ever implemented ??
[Sorry for the previous message, got sent inadvertently while I was in the middle of writing it ! :-/ Discard it] Hi group, Sometimes I wonder about this... maybe the experts on here have some view on
By Vince · #147836 ·
Automatic Brightness Control : was it ever implemented ??
Hi group, Sometimes I wonder about this... maybe the experts on here have some view on this ?? I mean, the brightness of the trace varies consid¨¦rably depending on sweep speed, ranging from blinding
By Vince · #147835 ·
Re: Tek 565 tubed
Shame when that happens; a full complement of tubes is not cheap to source and full calibration will be necessary. Also, the 565 can be prone to crt heater isolation breakdown and HV transformer
By widgethunter <tubesnthings@...> · #147834 ·
Re: CSA803 power-on error E2131
I doubt that communication via RS-232 or GPIB would be possible now that the system "hangs" after the error messages at start-up. I don't understand yet where or how an interrupt is generated. Is the
By Albert Otten · #147833 ·
Re: 453 calibrator
Hey Jack, Despite I'm member of this group for about 2 years, I consider myself still a rookie about Tektronix stuff. Specially because their product catalog is so small... What? Some 3 thousand items
By Fabio Trevisan · #147832 ·
Re: CSA803 power-on error E2131
As I said mine was a 2430a and all the cal and setup data was on the two dallas chips, as to what is stored where only Tektronix would know, I just copied the chips and replaced them adding a pair of
By Dewey Wyatt · #147831 ·
OT: Repair website
This site seems to have repair guides for a load of things : https://www.ifixit.com/ Enjoy. Geoff.
By Geoffrey Thomas · #147830 ·
Re: CSA803 power-on error E2131
The Dallas chips were totally gone indeed (date code 9106). I can't find in the CSA803A service manual what precisely is stored where. The error T1331 should not prohibit normal operation (at
By Albert Otten · #147829 ·
Upgraded, stub tuned, Tektronix SG-504 leveling head back online for a last run
Hello All: Since I posted the DIY for this item on hackaday.io I let the built Ebay items sell out. However, lately I have been getting requests to purchase this item again. 3 times in this week
By Ancel · #147828 ·
Re: 453 calibrator
You should be aware of a company called Tektronix, which makes the P6042 current probe. DC-50Mz Hall effect / coil First offered in 1969! I think you can find a manual on the web. I have one and it
By Jack Wills · #147827 ·
Re: Slightly OT. What is the grime I always see in HV areas?
Jeff, The Pioneer, sets were just a little less of a nightmare than Sony, neither had enough volume of sales nor problems to be regular in any way, Mitsubishi were a dream to work on, in my area
By Craig Thibodeaux · #147826 ·
7633 readout drift
When powering on the scope from cold the readout is high by about half a graticule. After 3-5 minutes of warm up the readout drifts to the center of the top graticule. Is this normal for this to
By Brendan · #147825 ·