Date
Re: Tek 455 Advice Please [3 Attachments]
The regulated +32 volt supply should have much lower ripple than that. Even if your ESR meter is reliable, ESR is not the whole story since the capacitance could be low. Given the age of the
By David Hess · #103158 ·
Re: Tek 455 Advice Please [3 Attachments]
If that is the ripple on the regulated outputs, I would replace the caps. Especially the one on the +32 regulated supply as it is also the reference for the +5 supply. It looks like the calibration
By Tom Miller · #103157 ·
7854 Quick Reference Cards
The 7854 has a set of four plastic quick-reference "cards" stored in a plastic housing on the top left of the instrument. Mine have all of the protruding tabs broken off, the tabs that show what each
By Dave Daniel · #103155 ·
Tek 455 Advice Please
I have a TEK 455 that a friend gave to me and it has an issue with the trace poor geometry. In XY mode, the trace is oblong and out of focus. I suspected possible PS filter issues so I measure the
By Jim Stadtfeld · #103156 ·
Re: Tektronix 2710 Spectrum Analyzer Unable to Coun t (VCO,IF)
Hi! Glad I can help :-) PSU The PSU problem You have is the same as mine. The display is pulseing and is not stable. If You connect an oscilloscope to the +115 test point You will see huge ripple
By Jakub Kazubek SQ8NGH · #103154 ·
Re: Dallas Chips and battery backup
Jay, Can you elaborate on how you know the DS1556 will work in the TDS700 series of scopes? Have you tried it? This doesn't make any sense because the memory map is completely different for a
By @Arcticgeek · #103153 ·
067-0532-00 Leveling head problem. Resonance?
Some time ago I reported that this 65-500 MHz GR-based oscillator had a nice flat frequency response. But at present the output amplitude is about 10% too high in a small region around 465 MHz. When I
By Albert Otten · #103152 ·
Re: Need advice on 2465A trig. config
The Scope probe is a Tek 10X fixed, 500Mhz BW, and it seemed to report exactly the voltage seen by the ADC based on what the PIC reports on the LCD. I have used the Tek scope data to create a
By mosaicmerc · #103151 ·
OT: Yahoo Groups question
Hi guys, I've been asked to set up a mailing list. My first thought was the highly acclaimed Yahoo Groups which served us so dear and well over the years. One would want to be able to migrate away at
By cheater cheater · #103150 ·
Re: Tektronix 2710 Spectrum Analyzer Unable to Coun t (VCO,IF)
Thanks, now that I know the front panel response is slow I will look elsewhere (CFC). The rotary encoder has issues, you can barely get it to work. I also think that the microprocessor may
By cmbath · #103149 ·
Re: Tektronix 2710 Spectrum Analyzer Unable to Coun t (VCO,IF)
Hi Kuba, Thanks for the very detailed and clear reply. I have copied your reply below and put some comments\questions below each paragraph¡­. ¡¤ It seems that there is more of us
By cmbath · #103148 ·
Re: 2236 vs 2245a
Thank you for all your comments, very interesting to see the user's perspective and not just advertising.
By Jmav Rick · #103147 ·
Re: Need advice on 2465A trig. config
Capacitive ADCs often have problems with high impedance inputs and those integrated
By David Hess · #103146 ·
Need advice on 2465A trig. config
Hi all: I have a waveform (5 V logic) driving a 16 x 2 LCD from a PIC Mcu. 3 of the data lines switch to become analog ADC inputs between sequential LCD character refreshes. The ADC sampling happens
By mosaicmerc · #103145 ·
Re: TDS3054B Noisy encoders on V & H Scales
Congrats, Victor. I'd be interested in hearing the actual vertical channel bandwidth you measure on the TDS3054B and see how it compares to the 500 MHz spec. I've measured ~500MHz on my
By honolulusnowwhite · #103144 ·
Re: 2236 vs 2245a
I usually end up connecting the vertical output to one of my DSOs but a timer/counter would also be good except for gated measurements. The 11302A is definitely the king of the hill as far as
By David Hess · #103143 ·
Re: Tektronix 2710 Spectrum Analyzer Unable to Coun t (VCO,IF)
Well the front panel buttons are stiff. And delayed Just as the rotary encoder. You have to operate it very slowly... It is normal in 2710. Your uC board is rather Ok.I would Look into cfc. Kuba 22
By Jakub Kazubek SQ8NGH · #103142 ·
Re: Tektronix 2710 Spectrum Analyzer Unable to Coun t (VCO,IF)
Hi Fred, I did try the normalisations and they all fail. The frequency counter tests in the diagnostic menu also fails. I have not checked the battery, but suspect the issue probably is not the
By cmbath · #103141 ·
Re: Tektronix 2710 Spectrum Analyzer Unable to Coun t (VCO,IF)
Hi ! It seems that there is more of us (un)happy Tektronix 2710 SA users. My Tek2710 is now put together but still has minor problems with it;s power supply and ripple (in the tek2711 and 2712
By Jakub Kazubek SQ8NGH · #103140 ·
Re: 2236 vs 2245a
For a Counter / Timer in a scope: Some scopes have a buffered channel output on the back. That lets one use a FET probe t look at small RF signals. Then pipe the output to a regular counter. I also