¿ªÔÆÌåÓý

Re: Type of power divider
Hello Harke, What setup did you use in your comparison of the power sensors? 1) Signal generator connected to the input port 1 of the 11667B and port 2 of the splitter connected to a power sensor used
By Razvan Popescu · #152123 ·
Re: Type of power divider
Hi Harke Sorry I am not good with computer lineages but I hope to use lab view with a friends help I have heard of python script but is new to me so perhaps you could PM me and give me a bit of a
By Paul Bicknell · #152122 ·
Re: 8643A CLIP - Artekmanuals
Hi Christian. strange? I recently placed an order and received the link within hours on the Mon 19/05/2025 ordered approx? 14:00 received the link at 20:27 but watch out the incoming Mail was
By Paul Bicknell · #152121 ·
Re: Type of power divider
Hello Paul, I did something like that a couple of years ago, in coax. A HP438A power meter, a HP1667B splitter and a HP8673B generator will do the job. I compared two HP8485 sensors. All GPIB
By Harke Smits · #152120 ·
Type of power divider
Hi all as I am after a bit of advice I want to compare power sensors up to 26 Ghz and there appear to be more than one Type of power divider available so looking for guidance to the one I should
By Paul Bicknell · #152119 ·
8643A CLIP - Artekmanuals
Hi everybody. On May 17th, I ordered on the Artekmanuals website, and paid with Paypal 25$, the 8643A CLIP with electronic delivery but nothing was sent. So far, I emailed twice to the official email
By santa0123456 · #152118 ·
Re: HP8757E GPIB issue
Hi again Harke. Understood, but as before, are they all proven working with other known good GPIB instruments? You do know, that you can put the AR488 devices into a "listen only" mode, and use them
By Dave_G0WBX · #152117 ·
Re: HP8757E GPIB issue
Hi Harke , the GPIB talk error message is displayed by the instrument or the by the SW ? The instruments goes in Talk mode ? My suggestion is to check the configuration of the string terminator of the
By Maurizio IZ1MDJ · #152116 ·
Re: 16903: Replace motherboard?
I upgraded the motherboard in my 16903A a couple of years ago, and it was a HUGE improvement overall of the instrument. It feels zippy and fast, and modern now. I mostly followed the guidance of that
By Andrew Hakman · #152115 ·
Re: HP8566B band amplitude response discrepancy - how much indicates a component failure?
After quite a bit of experimenting and poking around in various sections, I'm convinced that the frequency alignment of the YTO and YTX are OK, and the real problem is loss of conversion gain somehow
By ed breya · #152114 ·
16903: Replace motherboard?
Fellow techies, ??? I recently became the new owner of a 16903A logic analyzer. From what I've read, on EEVBlog, it's possible to upgrade the motherboard within a specific range (limited by which
By Bruce Lane · #152113 ·
Remote operation of Agilent 16702B from Windows 11 (Pro)
I'm sorry to be asking this question as I imagine it's been answered before but here goes. I'm trying to remote access my 16702B analyzer (Opt 3) from my windows laptop.? The maddning thing is that I
By Marc Howard · #152112 ·
Re: HP8757E GPIB issue
Dave, I have several: Prologix, AR488 and HP85327(?). I used them all with same or similar result. In this case the Prologix adapter is most appropriate. The GPIB status leds on the analyzer lit
By Harke Smits · #152111 ·
Re: 16700A How to change baud rate when using boot menu via RS232?
"norbinz via groups.io" <norbinz@...> writes: Ok. You're correct - the custom video mode is written to Flash. I reverse engineered the format for the Visualize FX cards many years ago,
By Sven Schnelle · #152110 ·
Re: HP8757E GPIB issue
Hi. What are you using (HW & SW) as the bus controler? Does it work OK with other instruments etc? Regards. Dave B.
By Dave_G0WBX · #152109 ·
Re: HP-8640B ¨C Frequency Counter Issue in Normal Mode
I had a problem with one of mine where one of the switches wasn't popping all of the way out. I don't recall if I managed to just exercise it a bit too recover or I sprayed it with a bit of contact
By Dave W6OQ · #152108 ·
Re: 16700A How to change baud rate when using boot menu via RS232?
Yes, my analyzer has option 003. It can output 1600x1200 at 75 Hz, but that's too fast for (probably all) 1600x1200 LCD monitors. My old ViewSonic VP201b almost works, but jitters. I've already tried
By norbinz · #152107 ·
(US only) - need power transformer from HP 8970A noise figure analyzer
The power transformer in my HP 8970A noise figure analyzer was DOA (internal short circuit). I'm using a patchwork of external DC supplies to operate it currently, however, I'm pretty sure that
By David Feldman · #152106 ·
Re: 16700A How to change baud rate when using boot menu via RS232?
"norbinz via groups.io" <norbinz@...> writes: It's PA-RISC I/O space. All of the peripherals and Firmware (PDC) are located there. Does your LA have Option 003? If not, there's not
By Sven Schnelle · #152105 ·
Re: HP Basic reference manual
blast.. wrong key "I did buy a number of HP items from Patricia. It is all from an estate sale
By Wilko Bulte · #152104 ·