On Mon, Mar 24, 2025 at 7:49?PM Rick Ellison via <rellison=[email protected]> wrote:
On the 7300 Click Menu then Set then Connectors The USB Send Keying What are your settings in that window??? On my 7300 I have:
USB SEND Off
USB Keying (CW) DTR
USB Keying (RTTY) Off
On your second sceenshot of the PTT settings under PTT on CAT Serial Port in the first dropdown box set that to None. On the CW Keyer under the config I have selected Use CAT and for Keyline I have DTR selected.
I can type in the window and it is sent and I can use the Macro buttons and they get sent also.
If you have been doing a lot of changes it might be helpful to go into the Flrig directory and delete the settings file.
Subject [winfldigi] FLRIG 2.0.05 and IC-7300 PTT/Transmit problems in CW #cw #flrig #IC-7300 #windows11
I'm in the process of learning CW, using the MorseMania app and I'm doing really well on instant character recognition, but I have 0 sending skills at the moment.
?
I'd like to use FLRIG or FLDIGI to send CW but I'm having problems... when I use the CW Keyer in FLRIG, it doesn't trigger the IC-7300 to transmit? If I use the same application to do FSK Keyer - it works fine...? And so does the "PTT" and "TUNE" button on the main FLRIG window...
?
Anyone have experiences with FLRIG and the IC-7300 CAT PTT? Here is how I have FLRIG configured:
?
?
Any and all reasonable suggestions are greatly appreciated ?