Locked
Re: 'signalHeadManagerInstance' not found in 4.9.2?
Bob: I don't see where I have made any script references to jmridefaults.py, but renaming jmri_bindings.py to that name resolved my issue. Thank you (again). I had to change some script references to
By
randomburnout@...
·
#139198
·
|
Locked
Re: Having trouble starting DP with Sprog2v3
You need to go to Preferences->Connections and select a valid serial port from those available. The valid name for a SPROG connection will be something like cu.usbmodemxxxx (not the tty.usbmodemxxxx).
By
Dave Heap
·
#139201
·
|
Locked
Re: Test version 4.9.2 problems under Windows 7
Bob, I installed 4.9.2 again. Then I checked for the decoderindex.xml file and I did have that file under My_JMRI_Railroad. I moved it out of there then launched DecoderPro. I put it through lots of
By
5i5kb4wwnc2tul2puyiz46rnzqoc733wbkjzio4p@...
·
#139197
·
|
Locked
Re: Test version 4.9.2 problems under Windows 7
Might be more than one problem. Could you try the #1765 (or later) installer from http://jmri.tagadab.com/jenkins/job/Development/job/Packages/ please? It¡¯s building now, should be done in about 20
By
Bob Jacobsen
·
#139196
·
|
Locked
Re: DCS240 JMRI
Will look tomorrow when I get to club Sent from Yahoo Mail on Android
By
ronmerrill69
·
#139195
·
|
Locked
Re: DCS240 JMRI
User with problems with a DCS240 and a locobuffer. I would like to know what the version number of the loco buffer is.. Its the first number when you select Loconet>LoconetStats. Walt
By
walter.stanley.thompson.3@...
·
#139194
·
|
Locked
Re: 'signalHeadManagerInstance' not found in 4.9.2?
If you have scripts referring to ¡°jmridefaults.py¡±, please replace that with a reference to ¡°jmri_bindings.py¡±. Or you could copy the ¡°jmri_bindings.py¡± file to be named
By
Bob Jacobsen
·
#139193
·
|
Locked
Re: DCS240 JMRI
My programing track is less than 3ft away. We upgrade from a dcs 200. But we also have 5 sections each control 30 ft at max. My DCS240 is the main and controls antennas, programing track, and a 2
By
ronmerrill69
·
#139192
·
|
Locked
Re: DCS240 JMRI
I would like to add some interesting observations here, I also hooked up a new dcs240 from a dcs 100. Initially I had a 30 ft run from the command station on 12 gauge running to a dcc specialties
By
Tristan Dwyer
·
#139191
·
|
Locked
Re: DCS240 JMRI
I'm running 4.8..,
By
Richard Neibert
·
#139206
·
|
Locked
Re: DCS240 JMRI
I get that error when the PR3 is in the wrong mode on my home set up with a DCS200. Our club uses the 240 just for running the layout so we haven't run in to this with it. So not sure how to change
By
David Klemm
·
#139190
·
|
Locked
Re: DCS240 JMRI
Did you do the update v.3 on the DCs240? [Non-text portions of this message have been removed]
By
Richard Neibert
·
#139189
·
|
Locked
Re: DCS240 JMRI
Will need to get back with you, but I installed newest version that was not a test version, I think 4.8 production release Sent from Yahoo Mail on Android On Mon, Aug 14, 2017 at 9:28 PM, DAVID KLEMM
By
ronmerrill69
·
#139188
·
|
Locked
'signalHeadManagerInstance' not found in 4.9.2?
Upgraded from 4.9.1 to 4.9.2 and now it does not like this line from jmridefaults.py and stops dead before showing any of my Layout Editor Panels. Any thoughts? 2017-08-14 21:18:35,692
By
randomburnout@...
·
#139187
·
|
Locked
Re: DCS240 JMRI
What version of JMRI are you running? The 240 was addressed around 4.7.2. David Klemm Sent from my iPhone 7 Plus ________________________________ Sent: Monday, August 14, 2017 7:12:32 PM To:
By
David Klemm
·
#139186
·
|
Locked
Re: DCS240 JMRI
no, I'm asking if its a valid fix
By
ronmerrill69
·
#139185
·
|
Locked
Re: Importing Layout Scematic from Anyrail
Ray, I believe AnyRail lets you export a layout to an image file (JPG, PNG?). If so, then the easiest thing to do would be to place that image onto your panel as an icon. I've built schmatics of my
By
rzeollaorcl
·
#139184
·
|
Locked
Re: DCS240 JMRI
ronmerrill69 Am I reading this correct? You fixed the problem by uninstalling the driver and reinstalling it, Walt
By
walter.stanley.thompson.3@...
·
#139183
·
|
Locked
DCS240 JMRI
I installed a DCS240 on our Club layout. I did my research on the new system, reading online that the DCS240 used the same drivers as the PR3, so I installed just prior to a week of vacation. the
By
ronmerrill69
·
#139182
·
|
Locked
Re: Slot monitor is blank
Terry: But when we ask a question about how something is set " No change" is not how it is set!
By
walter.stanley.thompson.3@...
·
#139181
·
|