Locked Re: Tcs m1 decoder
Thank you for the technical info I am convinced I will be using 3 dc cab power supplies Tony
By AD · #163126 ·
Locked Re: Tcs m1 decoder
Thank you for the info Project is more difficult than i was let o believe. I will be using 3 dc cab power supplies Tony
By AD · #163125 ·
Locked Re: DecoderPro missing on my RPi #rpi
Thanks everybody for all the help! You saved me a bunch of wasted effort trying to start over installing JMRI... I was able to quickly find and start it. I've also edited the owner fields and added
By Don Weigt · #163124 ·
Locked Re: Help with JMRI and Digitrax PR4
Hi George, A quick update. It appears the problem is not with my PR4 but with my DN163A0. As you suggested I tried another locomotive on my test track with the Digitrax Sound Loader and it read that
By Rich S <suziesuds@...> · #163123 ·
Locked best configuration for mixed gauge railroad
My friend has a railroad with Standard gauge and On30 trackage, with a very small common mixed gauge area. I view this basically as 2 seperate railroads is my thinking correct? What is the best way to
By Jim Kelly <jwkelly49@...> · #163122 ·
Locked Re: DecoderPro missing on my RPi #rpi
Two other approaches. Copy a profile and change the start up options to include Open Roster. If an icon is really important, copy the PanelPro icon with a new name and modify the properties. Dave Sand
By Dave Sand · #163121 ·
Locked Re: DecoderPro: cannot read/write values with LocoNet connection #loconet
Thank you all for your replies: that is very helpful. I am now away from home for a week, so I will have to try these recommendations when I get back. Thank you again!
By James E. Petts · #163120 ·
Locked Re: DecoderPro missing on my RPi #rpi
Click on Roster followed by Roster again in drop down menu. No need for a second start icon. -- Peter Ulvestad JMRI Users Group Moderator - http://www.jmri.org ( http://www.jmri.org ) Tam Valley Group
By Peter Ulvestad · #163119 ·
Locked Re: DecoderPro missing on my RPi #rpi
Don: The PanelPro pane on top, tools > programmers... Since the RPi-JMRI is targeted to running the RR I think Steve started with the PanelPro pane as a logical choice for that... Jim Albanowski
By jimalbanowski · #163118 ·
Locked Re: DecoderPro missing on my RPi #rpi
Don, Decoderpro is built into Jmri. It is not a separate entity. The user interface just looks different. Steve's image doesnt have the decoderpro launch icon, but you can still get to it from
By Tom Wilson · #163117 ·
Locked Re: DecoderPro: cannot read/write values with LocoNet connection #loconet
Is the problem involving JMRI 4.16 and Locobuffer USB a factor? If so, upgrading to 4.17 is apparently the fix. /g/Digitrax-Users/message/220164 Jan
By Jan Carr · #163116 ·
Locked DecoderPro missing on my RPi #rpi
I used Steve Todd's JMRI image to install working JMRI on my newish Raspberry Pi 3B+. PanelPro is finally working properly on it with simulated connections to my railroad. WiThrottle is working, too.
By Don Weigt · #163115 ·
Locked Re: Automation for dummies
Your 3 files are now located here: /g/jmriusers/files/ProblemsBeingWorkedOn/Haltz -- Peter Ulvestad JMRI Users Group Moderator - http://www.jmri.org ( http://www.jmri.org ) Tam Valley
By Peter Ulvestad · #163114 ·
Locked Re: Best way to read in decoders
Rob, The general procedure is to select new locomotive, identify the decoder (or if you know the decoder just select it). Once identified switch to the CVs sheet and read full sheet. However, You
By John Griffin · #163113 ·
Locked Re: Automation for dummies
Haltz, By going to the Files folder for this group and clicking twice on the word "Uploaded" near the upper right corner of the page, two sorts are provided. The first sort gives us the oldest upload
By Cliff Anderson · #163112 ·
Locked Train Building
I seem to have this problem with one train. The train is a 7 car turn.I use 7 moves in the outgoing yard. When I build the train I show only 6 cars.I cannot find anything in the build report to answer
By gerardh1031@... · #163111 ·
Locked Re: Possible PanelPro bugs #layouteditor
Don, The profile selector option is stored in settings:PanelProConfig2.properties and settings:DecoderProConfig3.properties. For Windows, settings: is mapped to "C:\Users\<username>\JMRI¡±. In Linux
By Dave Sand · #163110 ·
Locked Re: Possible PanelPro bugs #layouteditor
Don W, One important detail: do you still have the original panel file? Second, a comment about the preferences. I think you said you were using CMRI, if so, read on, if not skip the rest as not
By Ken Cameron · #163109 ·
Locked Re: DecoderPro: cannot read/write values with LocoNet connection #loconet
James, If you¡¯ve built the HDL keypad as part of the HDL command station, you may be able to watch the loconet packets with JMRI (assuming the HDL setup transmits the packets to LocoNet). That might
By Nigel Cliffe · #163108 ·
Locked Re: Automation for dummies
One way to do something like this would be to turn on the Wiki feature of the group. By selecting the ¡°subscribers and moderators can view and edit¡± (which means the public can¡¯t, i.e. you have