开云体育

Date
Locked Re: Which Dapol Imperium do I pick from the JMRI list? #definitions
Duncan: I think you need to rephrase your comment. How long does it take for a volunteer to gather the correct data to add a new decoder to JMRI? You make it sound like "the wonderful people" are too
By Morgan f Bilbo · #216851 ·
Locked Re: Zimo Decoder MS950 and MS990 Definitions #zimo
Read these pages carefully: https://www.jmri.org/help/en/html/apps/DecoderPro/CreateDecoder.shtml and https://www.jmri.org/help/en/html/apps/DecoderPro/CreateDecoderAdvanced.shtml You also need a
By Nigel Cliffe · #216850 ·
Locked Re: Which Dapol Imperium do I pick from the JMRI list? #definitions
Duncan If it doesn’t show up when you do a New Loco, it means that particular decoder hasn’t been defined to JMRI. To be blunt, that’s because none of the wonderful people who maintain and
By Mick Moignard · #216849 ·
Locked Re: Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder. #tcs
Ah, my mistake on diesel vs steam. The correct file is 'xml/decoders/TCS_WOW_steam04.xml’. The reset sections in the files are the same. JMRI’s CV="T2CV.5.0" default=“8” does exactly what
By Bob Jacobsen · #216848 ·
Locked Re: Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder. #tcs
Bob, #1.) We are using TCS Steam WOW-121. Your prior post references diesel.....which is incorrect. #2.) I don't know what " <factReset label="User Preset 1" CV= *"T2CV.5.0"* default="8"/> " T2CV.5.0
By Tim Kelley <tim.kelley@...> · #216847 ·
Locked Re: Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder. #tcs
The decoder file (xml/decoders/TCS_WOW_Diesel04.xml) has this for its reset definitions: <resets> <mode>PAGEMODE</mode> <mode>DIRECTMODE</mode>
By Bob Jacobsen · #216846 ·
Locked Re: Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder. #tcs
Good morning Bob, I've been through many of those documents. "Reset / Factory Reset / USER PRESET 1" is what TCS calls their "Nuclear Reset". It is my understanding that if you have NEVER saved to
By Tim Kelley <tim.kelley@...> · #216845 ·
Locked Re: Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder. #tcs
Is this related to the TCS-Users thread at /g/TCS-Users/topic/98477162 ? It sounds like the decoder isn’t executing the reset, at least not in the way you’re expecting. The are
By Bob Jacobsen · #216844 ·
Locked Re: Loco moving only during sensing decoder type | Decoder Pro
Thomas Just because you have the roster entry created, you are missing the second step of roster creation. Read all sheets. WHen you first create a toster entry, the data is filled with default data.
By thomasmclae · #216843 ·
Locked Re: Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder. #tcs
Good morning Bob, I am pretty sure it is TCS Decoder WOW Steam 121 SS4 (Sound Set 4). -Tim
By Tim Kelley <tim.kelley@...> · #216842 ·
Locked Re: Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder. #tcs
JMRI has a bunch of WOW 121 models: WOWDiesel V5 121 WOW Diesel 121 SS2 WOW Diesel 121 SS3 WOW Diesel 121 SS4 WOW Diesel 121 SS4 Prime WOW Diesel 121 EMD WOW Sound 121 WOW Steam 121 SS4 Could you
By Bob Jacobsen · #216841 ·
Locked Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder. #tcs
Good morning, I believe there may be a possible bug in JMRI / DecoderPro when using a TCS WOW-121 Steam Decoder. I have the latest test release of JMRI running (5.3.5). I have a Digitrax DCS240+
By Tim Kelley <tim.kelley@...> · #216840 ·
Locked Re: JMRI with DCC EX Command station - error message 303
Thanks Kevin. It’s OK now.
By Joe McCarthy · #216839 ·
Locked Re: Loco moving only during sensing decoder type | Decoder Pro
Wouter might be on to something. Are you trying to run the locomotive on the programming track? Some command stations can do that and some can't. Did you, in fact, put the locomotive on the layout
By Ken Heywood · #216838 ·
Locked Re: No launch from Win10 User account (admin account OK)
Mark yes. I ran into a problem, not manifested in the same way. Oracle was sitting there unbeknownst to me. Oracle uninstall app solved my problem. -- Ken NYNH&H, Old Colony Division, Cape Cod Branch
By Ken Heywood · #216837 ·
Locked Re: Which Dapol Imperium do I pick from the JMRI list? #definitions
It didn’t show those above, I will double check and get back to you Mick. Thanks Duncan
By Duncan · #216836 ·
Locked Re: Which Dapol Imperium do I pick from the JMRI list? #definitions
Either will probably do. They’re actually LaisDCC decoders. It may well be that the two decoder choices both give the same response to JMRI when it interrogates them, which means it can’t tell
By Mick Moignard · #216835 ·
Locked Re: Loco moving only during sensing decoder type | Decoder Pro
Hi Thomas, When you try to control your loco, what is the loco address you use, and how did you determine that that was the right one? From the story so far, I get the feeling that you are expecting
By whmvd · #216834 ·
Locked Re: RFID Connectivity #rfid
Blair wrote, " I thought that up to eight sockets could be used to plug the readers into. Then the seven wires from each reader can be easily routed to where they need to be. The question is, where do
By miktrain · #216833 ·
Locked Re: JMRI with DCC EX Command station - error message 303
Hi Joe, What version of DCC-EX are you running? You can Send a lower case?? s?? status which will display the version in the traffic monitor screen. The 303 error is saying you're attempting to
By Kevin · #216832 ·