1.0.3 control panel
Bob,
1. When I create a new control panel and add icons, nothing is visible on
the panel until I resize it. After I resize the panel everything is there.
I tried different X and Y values and it
By
Robin Becker <n3ix@...>
·
#307
·
|
Locked
1.0.3 control panel questions
Bob or other control panel guru,
Once icons are placed on the control panel, the tooltip says "Alt-click to
see menu, drag with meta key..." Ok, I can move the icons around with the
right mouse
By
Robin Becker <n3ix@...>
·
#306
·
|
Locked
Getting ID info (was Re: 1.0.3 test installer uploaded)
Wow, what a quick response! The miracle of time zones...
Thanks for the trace. I can read the reply from that. The ID of that came back as 129 (digitrax), version 241, which is a new code I'd not
By
Bob Jacobsen
·
#305
·
|
Locked
Re: 1.0.3 test installer uploaded
Looks good
It found my previously configured decoders ok but when I did an ident it
failed to find my DN149K2s.
I guess there must be more than one DN149K2 version, so here is the trace.
time:
By
Alex Shepherd <ashepherd@...>
·
#304
·
|
Locked
1.0.3 test installer uploaded
I've just uploaded the 1.0.3 test installer.
This is a _test_ installer. I'm away from home this week, and haven't been able to really wring it out on my layout. As always, I strongly recommend
By
Bob Jacobsen
·
#303
·
|
Locked
Re: Decoder Pro - WOW!
Mike:
How did you connect Decoder Pro to your system? Are you using MS100 (from PR1)? Is it a RJ11 plug to a 25 pin adapter? Can't get mine to see the loco on programming track.
Bill
By
billroger <billroger@...>
·
#302
·
|
Locked
Re: CVP's EasyDCC AD4 Accessory Decoder
The AD4 splits its address across two CVs, which is a bit of a pain to do manually. I wrote a little bit of code so that we can specify that in a decoder file, and created an AD4 definition file to
By
Bob Jacobsen
·
#301
·
|
Locked
controlpanels
Bob,
we have build for clients many panels, we have pictures for
Swiss, Autriche and Germany called INTEGRA, VGS, and SpDr60
construct by SIEMENS and for the United States CTC type
GE-Harris. We will
By
broman40de <berg.broman@...>
·
#300
·
|
Locked
Re: Coping with the user-fiendish features of the DZ121
I haven't tried it but: The DCS100 can make the program track outputs into
a broadcast brake generator (still low current). This should provide power
to the decoder when not programming, then switch
By
Michael Mosher <mjmx1@...>
·
#298
·
|
Locked
Re: Coping with the user-fiendish features of the DZ121
I tried a test with my Digitrax DCS100 - the programming track is
unpowered until a read or write operation is done. Then the power
comes on, the action is performed and the power goes off. So I
By
millerdl
·
#297
·
|
Locked
Re: Easy DCC
Stony,
My 'vast' experience includes programming 2 SoundTraxx DSD-150 decoders so I
can't offer expert advice. You may want to contact CVP and run this problem
by them.
There is no risk of
By
Mike Davison <davison@...>
·
#296
·
|
Locked
Decoder Pro - WOW!
Downloaded and installed Decoder Pro on a _really_ old laptop. All I can
say is WOW! All contributors did an awesome job on this. I look forward to
using and possibly developing applications using
By
Maloney, Michael <michael_maloney@...>
·
#299
·
|
Locked
Re: Easy DCC
Mike
I may have spoken too soon. The 82 ohm resistor cured my problem with
SoundTraxx decoders but I still can't read values from Digitrax decoders.
I've tried resistors from 68 to 150 ohms with no
By
buchcty
·
#295
·
|
Locked
Re: Varieties of Digitrax Decoders
Bob,
Let me first say that while the decoders under discussion belong to Digitrax there are other decoder manufacturers that are effected in the same way.
This is just a suggestion and works in
By
Al Silverstein <MSILVERSTEIN@...>
·
#294
·
|
Locked
Re: Coping with the user-fiendish features of the DZ121
Bob Jacobsen wrote:
By
Mark Gurries <gurriesm@...>
·
#293
·
|
Locked
Re: Varieties of Digitrax decoders
Comments below
Bob Jacobsen wrote:
By
millerdl
·
#292
·
|
Locked
Re: Coping with the user-fiendish features of the DZ121
be a read-only variable on the programming screen.<
The PR1DOS software has a special DZ121 program button. I would suspect
the way that's done is to lock out programming CV01, basically what
By
Jon Miller <atsf@...>
·
#291
·
|
Locked
Coping with the user-fiendish features of the DZ121
At 3:15 PM -0700 7/31/02, Jon Miller described a nasty feature of the DZ121:
The nasty thing about this is that there's no way for DecoderPro to fix it while the decoder is on the programming track;
By
Bob Jacobsen
·
#290
·
|
Locked
Re: CVP's EasyDCC AD4 Accessory Decoder
I started to throw together a pane for this last night. In the process, I discovered that the address is split between two CVs, much like the long address in a locomotive decoder. It's inconvenient
By
Bob Jacobsen
·
#289
·
|
Locked
Re: it works
Great! I'm interested in working with you on this, esp. on signalling.
Also, if you create a set of good icons, please consider sharing them. It would be great to have more than just the simple ones
By
Bob Jacobsen
·
#288
·
|