Keyboard Shortcuts
Likes
- Jmriusers
- Messages
Search
Re: Colors for JMRI shirts (was re: JMRI merchandise for donations
I'd be down for a gray polo shirt. Thanks and take care. Cheers, Dennis Drury Dayton, NV The miracle is this: the more we share the more we have. Leonard Nimoy On Mon, May 19, 2025 at 1:10?PM Bob Jacobsen via <rgj1927=[email protected]> wrote: Daylight Sales got back to me.? They can do JMRI polo shirts, denim shirts, pocket t-shirts and/or coffee mugs. |
Fresh install of JMRI and Java on new Mac (Sequoia). PanelPro won't start ("To use JMRI you need to install Java 11" dialog comes up)
Sorry to be "another one of those guys" who missed something obvious. I'm trying to get JMRI 10 running on a new Mac running Sequoia.
?
First I installed the Azul version 17 LTS JDK with FX. I downloaded the zip file and put the resulting unzipped folder in my home directory under ~/bin/java and renamed the java root folder zulu-17.fx. (I did this to facilitate later, ongoing java upgrades when/if necessary.)
?
After moving and renaming the directory, I went into my .zshrc file and set JAVA_HOME to /Users/<myUserName>/bin/java/zulu-17.fx and my PATH to $JAVA_HOME/bin:$PATH. I then "source"d the .zshrc file and tried java --version and get:
?
openjdk 17.0.15 2025-04-15 LTS Even wrote a little "hello world" java program and javac works. Seems good. I installed JMRI V10 and fired up PanelPro. I get the dialog: ? ? ? I even tried logging out and logging in again just to be sure no bad paths were being cached anywhere. No change. I keep looking over the JMRI installation pages and don't see anything that looks like a step I missed. Can someone tell me what I skipped or otherwise did wrong? ? Thanks, Vince ?
|
Colors for JMRI shirts (was re: JMRI merchandise for donations
Daylight Sales got back to me. They can do JMRI polo shirts, denim shirts, pocket t-shirts and/or coffee mugs.
Now we get to pick a color! The available colors for each item are shown as swatches on these pages: Polo = Denim = Pocket t's = Coffee mugs are white. Note that our logo is mostly black and white, with just a touch of red: It might not show up well when embroidered on really dark colors. I¡¯m color blind, so give this a large grain of salt, but I suggest: ¡°Cool gray" for polo shirts ¡°Faded blue¡± for denim shirts ¡°Sport gray¡± for pocket t-shirts I¡¯m happy to follow any color consensus that emerges. Bob ¡ª Bob Jacobsen rgj1927@... |
Re: Startup Gets Stuck
#startup
Richard, I don't know if this has been requested. ?Upload the "messages.log" file located at C:\Users\<username>\JMRI\log to the group's ProblemsBeingWorkedOn file folder. Dave Sand ----- Original message ----- From: "rprdds24 via groups.io" <rprdds24=[email protected]> Subject: Re: [jmriusers] Startup Gets Stuck #startup Date: Monday, May 19, 2025 1:54 PM Mick, Thanks for the suggestion. Unfortunately, nothing is hidden. There are no vertical or horizontal bars and I tried dragging the screen with my mouse to expose anything. I even said "come out come out wherever you are" to no avail.? The taskbar icon is for the JMRI splash screen only.? -- Richard Richter |
Re: Startup Gets Stuck
#startup
Mick,
Thanks for the suggestion. Unfortunately, nothing is hidden. There are no vertical or horizontal bars and I tried dragging the screen with my mouse to expose anything. I even said "come out come out wherever you are" to no avail.? The taskbar icon is for the JMRI splash screen only.?
--
Richard Richter |
Re: DECODERPRO WARNING
Well, I'm no expert, but a couple of things struck me.? You said in your fourth sentence that you were programming on the main.? In my mind, that's not a good idea when resetting a decoder.? I would recommend doing on a programming track.? I'm guessing that you weren't really 'programming on the main', as that is generally ops mode.? And the I don't think that the dcc standard allows reading from the decoder in ops mode.? But maybe Lenz is different.? As to the speed going wide open, that could easily happen if you changed CV29 back to what it once was as one setting in there turns off the use of the speed table which is likely the factory default.? Did you change CV1 to a value of 3?? That would have been the factory setting.? If you did so on the main, then having all the locos now on address 3 makes sense.
?
On Mon, May 19, 2025 at 09:55 AM, Phillip Sifers wrote:
|
DECODERPRO WARNING
I was resetting some basic NCE and Digitrax mobile decoders back to their original programming.? For some reason I never could reset TCS, NCE decoders on my Lenz system.? No problem with Digitrax.? I had a Proto 2000 SW1000 with a NCE SW*-SR decoder to reset so I set about making changes in DECODERPRO.? Since it was not on my roster it was entered as a New Loco and read into the program to program on the main.? The decoder instruction leaflet had a list of the original CV's so that is what I was going to program.? Carefully changing only a few at a time and writing the sheet to make sure no mistakes were made, I dutifully? went down the list making sure the CV's were correctly changed.? The only CV's not changed were the speed table which contained a special switching program I had successfully used.? I saved the file and exited the program.;
?
WOW WHAT HAPPENED?? The little switcher took off like it was running on full DC and eleven other Layout loco's started running.? I quickly hit the stop but6ton on my handset; which stopped all but the little switcher.? which to me it meant analog running as the DC Component is still present on a LENZ stop function.? I quickly pulled it off the layout.? Looking at one handset i determined that Loco 3 was called up and had applied forward speed.? While still in stop mode I changed loco 3 speed step to zero and pressed the stop function.? No loco's were running.? The loco's that had been running now had address 3. Theo only other loco's on the layout that did not have their address changed were various sound locomotives of various manufactures. All of the Lo's were restored to their respective Loco numbers on the programming track and appeared to be unchanged otherwise. The little switcher still had it's? original number and would not run. I printed out the CV's for the SW9=SR as recorded in DECODERPRO.? Everything was there except the manufacturer ID.? That when it struck me.? Had I tried to program a dead decoder??? Will DECODERPRO even let you ???
COMMENTS PLEASE. |
Re: Looking for ideas to mirror SE8C signals between two panels
> Assuming that you are using "Signal Masts", it is MUCH easier to just > use JMRI "signal mast repeaters".? See >? I am using signal masts but the issue is the signal mast that I want to repeat/mirror is running on a different computer and separate instance of JMRI.? The SignalMastRepeater requires this instance of JMRI/panel to have the original signal mast defined in order to configure a repeater.? I'm trying to repeat a signal mast across two computers and two JMRI instances On Mon, May 19, 2025 at 5:42?AM billybob experimenter via <jawhugrps=[email protected]> wrote: On 5/18/2025 10:19 PM, cengel_74 via wrote: --
?Chris |
Re: Looking for ideas to mirror SE8C signals between two panels
On 5/18/2025 10:19 PM, cengel_74 via groups.io wrote:
My first attempt was to just write logix to monitor for the turnout status changes that are used to control the SE8C and then set the appearance of a virtual signal head to match the state.... Is there a better way to do what I'm trying to do or is there something wrong with my logix that will fix this issue?Chris, Assuming that you are using "Signal Masts", it is MUCH easier to just use JMRI "signal mast repeaters". See . |
Re: Engine and bell sounds work but no horn after decoder install
Hello Dan,
typically, for North American sound projects, the horn is not on sound slot 2 but on sound slot 3 or 4 (the one that's not the bell - I can't remember and projects.esu.eu doesn't load for me right now) If I were in your shoes, I'd ask the sound project number from Tony's Train Xchange and look it up on projects.esu.eu to find the bulletin and list of functions to verify, and/or download the project and open it with LokProgrammer software if you have a Windows 7+ machine available. You don't need the LokProgrammer hardware to run the LokProgrammer software and it will show you more info on the sound slots than JMRI can. Note: For sound, you don't need the Grade Crossing logical function. That's a modifier for the light outputs - if they are set to Ditchlight effect, they will blink as long as the Grade Crossing logical function is on. Hope this helps, Heiko -- eMails verschl¨¹sseln mit PGP - privacy is your right! Mein PGP-Key zur Verifizierung: |
Re: 12 hour JMRI clocks
¿ªÔÆÌåÓýSteve et al, I am late to this discussion but here is my two cents.?? I have lived with the 0 to 24 hour clock since my teen years.? I wish everyone and everything would go to the 24 hour clock.? I used it in cadets, in the navy, on the railway, in BC Corrections and with the Corps of Commissionaires on contract to the Saanich Police.? I it simple and straight forward with no room for question or misunderstanding. Paul On 2025-05-18 19:33, Steve_G via
groups.io wrote:
|
Re: 12 hour JMRI clocks
Early 12hr digital clocks that had an alarm had a dot in the top left of the first digit for PM. Public clocks and ones without alarms didn't need to tell you whether it was pre or post noon. Never ever saw one on a railway clock.
?
Before displaying the clock as 0 thru 24 was called Military time it was known as Railway time. The CPR has dispatched trains using 0 thru 24 std time for at least a hundred years though they used 0 thru 12 local times on printed schedules for end user consumption.
?
BR didn't switch until the 1960s, it could why it's called the old country......
?
Steve G.
?
?
?
? |
Looking for ideas to mirror SE8C signals between two panels
I'm working on getting signals and CTC running on a layout that has three separate dispatch panels for different zones running using?PanelPro.? Where those zones meet I'm trying to mirror the state of some of the signals between the two panels.? This is to enable the dispatchers?to know when trains are cleared up to their zones and to also enable some CTC logic to block one dispatcher from routing a train into a block if the other dispatcher has someone cleared into the block from their direction. The two dispatch panels are connected to a server using loconet over tcp so each one can see the activity on the loconet bus. My first attempt was to just write logix to monitor for the turnout status changes that are used to control the SE8C and then set the appearance of a virtual signal head to match the state. Ex: IX:AUTO:0039C9 ?Aurora WEB Main2 Green ? ? ? [x] ?R1 ?IF ?Turnout "LT1552" state is "Turnout Closed" ? ? ? ? ? ? ? ?THEN ? ? ? ? ? ? ? ? ?When Triggered True, Set Signal Head Appearance, "LH2" to Green ? ? IX:AUTO:0039C10 ?Aurora WEB Main2 Red ? ? ? [x] ?R1 ?IF ?Turnout "LT1552" state is "Turnout Thrown" ? ? ? ? ? ? ? ?THEN ? ? ? ? ? ? ? ? ?When Triggered True, Set Signal Head Appearance, "LH2" to Red ? ? IX:AUTO:0039C11 ?Aurora WEB Main2 Yellow ? ? ? [x] ?R1 ?IF ?Turnout "LT1553" state is "Turnout Thrown" ? ? ? ? ? ? ? ?THEN ? ? ? ? ? ? ? ? ?When Triggered True, Set Signal Head Appearance, "LH2" to Yellow ? ? IX:AUTO:0039C12 ?Aurora WEB Main2 Dark ? ? ? [x] ?R1 ?IF ?Turnout "LT1553" state is "Turnout Closed" ? ? ? ? ? ? ? ?THEN ? ? ? ? ? ? ? ? ?When Triggered True, Set Signal Head Appearance, "LH2" to Dark?? ? This worked in my testing as I was always changing the state of a turnout from closed->thrown or thrown->closed when testing using the turnout table manually.? However when tested on the real layout it didn't work. The panel could see the traffic when I monitored the loconet traffic: In this trace you see a 2 head signal where the aspect is changing from red over red -> yellow over red -> red over red.?? The problem with my logix is that the two turnouts that matter LT1552/LT1553 controlling the SE8C never actually change state in JMRI they are always in the thrown?state and just sent a message to 'Throw' which is then not triggering my logix as I expected it to.? I expected the 'Execute Actions whenever triggered' would mean that the logix would run everytime?the message to throw the turnout was sent but that doesn't appear to be the case. Is there a better way to do what I'm trying to do or is there something wrong with my logix that will fix this issue? ?Chris |
Re: JMRI merchandise for donations
Several NMRA Divisions as well as OpSIG use Daylight Sales for apparel so I'd almost be certain that they could do something for JMRI. However I'd caution against a white shirt. They don't stay white for long. A heather gray could work though.
Except for a? possible set-up charge to create the logo (about $125-$150), here's some examples of what certain shirts/jackets would cost.??Adding a name to the front is an extra $7.50.? Ed |
PanelPro - sluggish
this is on a modest sized club layout.? (see Illinois Midland Model Railroad club on FB)
?
We are using NCE PowerPro 5A serial/usb to a RPi.? ?panel pro 4.21.3? ?
?
I had control point turnouts setup and working well.
?
Then added PSX/AIU for detection. After adding in the sensors and the corresponding panel lights.
?
the function of the panel has become very sluggish, might take 20-30 seconds to throw a turnout/crossover.?
?
?Any ideas what has happened ?? ?too much for RPi? ?? ? only 8 sensors added, doesnt seem like that much, wanted to add about 6 more.
?
We have Azatrax so no jmri signaling.
?
any help or suggestions appreciated.
?
Bryan? |